Waters Micromass Q-ToF Guide

Micromass Q-Tof micro Mass Spectrometer Operator’s Guide 34 Maple Street Milford, MA 01757 71500058502 Revision A NOTICE The information in this document is subject to change without notice and should not be construed as a commitment by Waters Corporation. Waters Corporation assumes no responsibility for any errors that may appear in this document. This document is believed to be complete and accurate at the time of publication. In no event shall Waters Corporation be liable for incidental or consequential damages in connection with, or arising from, the use of this document. © 2002 WATERS CORPORATION. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF MAY NOT BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF THE PUBLISHER. Micromass and Waters are registered trademarks, and MassLynx is a trademark of Waters Corporation. All other trademarks or registered trademarks are the sole property of their respective owners. Safety Information General The Micromass Q-Tof micro is designed solely for use as a mass spectrometer; any attempt to use it for any other purpose is liable to damage the instrument and will invalidate its warranty. The Micromass Q-Tof micro mass spectrometer conforms to European standard EN61010-1:2001, Safety Requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements. The instrument has been designed and tested in accordance with recognized safety standards. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Whenever the safety protection of the instrument has been compromised, disconnect the instrument from all power sources and secure the instrument against unintended operation. The instrument must be installed in such a manner that the user can easily access and isolate the power source. Safety Symbols Warnings in this User’s Guide, or on the instrument, must be observed during all phases of service, repair, installation and operation of the instrument. Failure to comply with these precautions violates the safety standards of the design and intended use of the instrument. Micromass UK Limited assumes no liability for the user’s failure to comply with these requirements. The following safety symbols may be used in the User’s Guide, or on the instrument. A Caution is an instruction that draws the user’s attention to the risk of injury or death; a Attention is an instruction that draws attention to the risk of damage to the instrument. Caution: This is a general warning symbol, indicating that there is a potential health or safety hazard; the user should refer to this User’s Guide for instructions. Caution: This symbol indicates that hazardous voltages may be present Caution: This symbol indicates that hot surfaces may be present. Caution: This symbol indicates that there is danger from corrosive substances. Caution: This symbol indicates that there is danger from toxic substances. Caution: This symbol indicates that there is danger from flammable substances. Caution: This symbol indicates that there is danger from laser radiation. Attention: This is a general caution symbol, indicating that care must be taken to avoid the possibility of damaging the instrument, or affecting its operation. Q-Tof micro Mass Spectrometer Information Intended Use The Micromass Q-Tof micro Mass Spectrometer can be used as a research tool to deliver authenticated exact mass in both MS and MS-MS mode. It is not for use in diagnostic prodedures. Biological Hazard When you analyze physiological fluids, take all necessary precautions and treat all specimens as potentially infectious. Precautions are outlined in “CDC Guidelines on Specimen Handling,” CDC – NIH Manual, 1984. Calibration Follow acceptable methods of calibration with pure standards to calibrate methods. Use a minimum of five standards to generate a standard curve. The concentration range should cover the entire range of quality-control samples, typical specimens, and atypical specimens. Quality Control Routinely run three quality-control samples. Quality-control samples should represent subnormal, normal, and above-normal levels of a compound. Ensure that quality-control sample results are within an acceptable range, and evaluate precision from day to day and run to run. Data collected when quality-control samples are out of range may not be valid. Do not report this data until you ensure that system performance is acceptable. Table of Contents vii Table of Contents Preface ……………………………………………………………………………………………………. 1 Chapter 1 Overview ……………………………………………………………………………………………….. 5 1.1 Instrument Description………………………………………………………………………….. 6 1.1.1 Ionisation Techniques ………………………………………………………………. 6 1.1.2 Atmospheric Pressure Chemical Ionisation …………………………………. 6 1.1.3 Electrospray ……………………………………………………………………………. 6 1.1.4 Nanoflow Electrospray …………………………………………………………….. 7 1.2 Ion Optics ……………………………………………………………………………………………. 8 1.3 Internal Layout …………………………………………………………………………………….. 9 1.3.1 Mechanical Components………………………………………………………….. 10 1.3.2 Electrical Components ……………………………………………………………. 10 1.4 The Vacuum System……………………………………………………………………………. 12 1.4.1 Fine Pumping…………………………………………………………………………. 12 1.4.2 Rotary Pumping …………………………………………………………………….. 13 1.4.3 Pressure Measurement ……………………………………………………………. 13 1.4.4 Vacuum Protection …………………………………………………………………. 13 1.5 Front Panel Connections ……………………………………………………………………… 14 1.5.1 Desolvation Gas and Probe Nebuliser Gas …………………………………. 14 1.5.2 High Voltage …………………………………………………………………………. 14 1.5.3 Heaters …………………………………………………………………………………. 14 1.5.4 Front Panel Controls and Indicators …………………………………………. 15 1.6 Rear Panel Connections ………………………………………………………………………. 16 1.6.1 Water …………………………………………………………………………………….. 16 1.6.2 Nitrogen Gas In ……………………………………………………………………… 16 1.6.3 Exhausts ……………………………………………………………………………….. 17 1.6.4 Supply Inlet …………………………………………………………………………… 17 viii Table of Contents 1.6.5 Electronics ……………………………………………………………………………. 17 1.6.6 Rotary Pump …………………………………………………………………………. 17 1.6.7 Event Out ……………………………………………………………………………… 17 1.6.8 Contact Closure In …………………………………………………………………. 18 1.6.9 Analog Channels ……………………………………………………………………. 18 1.7 MassLynx Data System……………………………………………………………………….. 18 1.7.1 Software ………………………………………………………………………………… 19 Chapter 2 Routine Procedures …………………………………………………………………………….. 21 2.1 Start Up Following a Complete Shutdown……………………………………………… 21 2.1.1 Preparation …………………………………………………………………………….. 21 2.1.2 Pumping ……………………………………………………………………………….. 22 2.1.3 MCP Detector Conditioning ……………………………………………………. 23 2.1.4 Instrument Warm-up ………………………………………………………………. 24 2.1.5 Using the Instrument ………………………………………………………………. 24 2.2 Start Up Following Overnight Shutdown……………………………………………….. 24 2.2.1 Preparation for Electrospray Operation ……………………………………… 25 2.2.2 Preparation for APcI Operation ……………………………………………….. 26 2.2.3 Transient Pressure Trip …………………………………………………………… 27 2.2.4 Power Failure ………………………………………………………………………… 27 2.2.5 Nitrogen Supply …………………………………………………………………….. 28 2.3 Automatic Startup and Shutdown …………………………………………………………. 28 2.3.1 The Shutdown Editor ……………………………………………………………… 28 2.3.2 The Shutdown Editor Toolbar …………………………………………………. 29 2.3.3 Shutdown Page ……………………………………………………………………… 29 2.3.4 The Auto Control Tasks Page …………………………………………………. 33 2.3.1 Shutdown Log ……………………………………………………………………….. 36 Table of Contents ix Chapter 3 Electrospray ………………………………………………………………………………………… 39 3.1 Introduction ……………………………………………………………………………………….. 39 3.1.1 Post-column Splitting …………………………………………………………….. 41 3.1.2 Megaflow ……………………………………………………………………………… 43 3.2 Operation…………………………………………………………………………………………… 43 3.2.3 Megaflow Hints …………………………………………………………………….. 49 3.2.4 Removing the Probe ……………………………………………………………….. 50 3.3 Sample Analysis and Calibration ………………………………………………………….. 50 3.3.5 General Information ……………………………………………………………….. 50 3.4 Chromatographic Interfacing ……………………………………………………………….. 52 3.4.1 LC-MS Sensitivity Enhancement ……………………………………………… 53 Chapter 4 Nanoflow Electrospray ……………………………………………………………………….. 55 4.1 Installing the Interface…………………………………………………………………………. 57 4.1.1 Operation of the Camera System ……………………………………………… 60 4.1.2 Glass Capillary Option ……………………………………………………………. 61 4.2 Nano-LC Option…………………………………………………………………………………. 63 4.2.1 Installation …………………………………………………………………………….. 63 4.2.2 Operation ……………………………………………………………………………… 65 4.3 Changing Options……………………………………………………………………………….. 66 Chapter 5 APcI …………………………………………………………………………………………………….. 67 5.1 Preparation ………………………………………………………………………………………… 68 5.1.1 Checking the Probe…………………………………………………………………. 68 5.2 Obtaining an Ion Beam ……………………………………………………………………….. 69 5.3 Hints for Sample Analysis……………………………………………………………………. 71 5.4 Removing the Probe ……………………………………………………………………………. 72 x Table of Contents Chapter 6 Tuning ………………………………………………………………………………………………….. 75 6.1 Tuning ………………………………………………………………………………………………. 75 6.2 Tune Page ………………………………………………………………………………………….. 77 6.2.1 Tune Page Basics ……………………………………………………………………. 77 6.2.2 Saving and Restoring Parameter Settings ………………………………….. 78 6.2.3 Changing the Peak Display ……………………………………………………… 79 6.2.4 Source Tuning Page ……………………………………………………………….. 81 6.2.5 Quadrupole Tuning Page (Analyzer) ………………………………………… 83 6.2.6 Time Of Flight Page ……………………………………………………………….. 85 6.2.7 Other Tune Page Settings ………………………………………………………… 88 6.3 Obtaining an Ion Beam ……………………………………………………………………….. 89 6.3.1 Standard Tune Parameters ……………………………………………………….. 90 6.3.2 Checking the Resolution …………………………………………………………. 90 Chapter 7 Calibration …………………………………………………………………………………………. 93 7.1 Introduction ……………………………………………………………………………………….. 93 7.1.1 Nominal Mass Accuracy – Lteff ………………………………………………. 94 7.1.2 Calibration ……………………………………………………………………………. 95 7.1.3 Lock Mass …………………………………………………………………………….. 96 7.1.4 Deadtime Correction ………………………………………………………………. 96 7.2 Generation of an Instrument Calibration………………………………………………… 97 7.2.1 Calculation of Lteff…………………………………………………………………. 97 7.2.2 Acquire Data for Calibration …………………………………………………… 99 7.2.3 Check for Deadtime Distortion ………………………………………………. 100 7.2.4 Calibration ………………………………………………………………………….. 102 7.2.5 LockMass Correction ……………………………………………………………. 106 7.2.6 Deadtime Correction …………………………………………………………….. 106 7.3 Exact Mass Measurement: Additional Hints…………………………………………. 109 Table of Contents xi Chapter 8 Data Acquisition ………………………………………………………………………………… 111 8.1 Starting an Acquisition………………………………………………………………………. 111 8.1.1 Starting an Acquisition from the Tune Page……………………………… 111 8.1.2 Multiple Samples …………………………………………………………………. 114 8.2 Monitoring an Acquisition …………………………………………………………………. 114 8.2.1 The Acquisition Status Window ……………………………………………… 114 8.2.2 Chromatogram Real-Time Update ………………………………………….. 115 8.2.3 Spectrum Real-Time Update ………………………………………………….. 115 8.2.4 System Manager ………………………………………………………………….. 115 8.2.5 Stopping an Acquisition ………………………………………………………… 115 8.3 The Experiment Setup Editor……………………………………………………………… 115 8.3.1 The Experiment Setup Editor Toolbar ……………………………………… 116 8.3.2 Adding a New Function ………………………………………………………… 117 8.3.3 Modifying an Existing Function …………………………………………….. 117 8.3.4 Copying an Existing Function ……………………………………………….. 118 8.3.5 Removing a Function ……………………………………………………………. 118 8.3.6 Changing the Order of Functions ……………………………………………. 118 8.3.7 Setting a Solvent Delay …………………………………………………………. 119 8.3.8 Analog Channels ………………………………………………………………….. 120 8.3.9 Saving and Restoring a Function List ……………………………………… 120 8.3.10 Setting up an MS Scan Function …………………………………………….. 121 8.4 Automated Data Dependent Acquisition (DDA) …………………………………… 125 8.4.1 Creating a Data Dependent MS to MS/MS Switching Experiment. 126 8.4.2 Survey ………………………………………………………………………………… 127 8.4.3 MS to MSMS ………………………………………………………………………. 128 8.4.4 MSMS to MS ………………………………………………………………………. 131 8.4.5 MSMS Template ………………………………………………………………….. 132 8.4.6 Include Masses …………………………………………………………………….. 133 8.4.7 Collision Energy ………………………………………………………………….. 135 xii Table of Contents 8.4.8 Exclude Masses ……………………………………………………………………. 137 Chapter 9 Parent Ion Discovery …………………………………………………………………………. 139 9.1 Creating a Parent Ion Discovery Experiment………………………………………… 139 9.1.1 Parent Survey Window ………………………………………………………….. 140 9.1.2 Product Ions ………………………………………………………………………… 142 9.1.3 Neutral Loss ………………………………………………………………………… 143 9.1.4 MSMS Template ………………………………………………………………….. 144 9.1.5 MS to MSMS ………………………………………………………………………. 145 9.1.6 MSMS to MS ………………………………………………………………………. 148 9.1.7 Include ……………………………………………………………………………….. 149 9.1.8 Exclude ………………………………………………………………………………. 151 9.1.9 Collision Energy ………………………………………………………………….. 152 Chapter 10 Maintenance and Fault Finding ……………………………………………………….. 155 10.1 Electronics Maintenance ……………………………………………………………………. 156 10.1.1 Cooling Fans and Air Filters ………………………………………………….. 156 10.1.2 The Vacuum System …………………………………………………………….. 156 10.2 The Source……………………………………………………………………………………….. 159 10.2.1 Cleaning the Sample Cone in Situ …………………………………………… 160 10.2.2 Removing and Cleaning the Sample Cone ………………………………. 163 10.2.3 Removing and Cleaning the Source Block and Extraction Cone … 165 10.2.4 Removing and Cleaning the RF Lens Assembly ………………………. 167 10.2.5 Reassembling and Checking the Source ………………………………….. 168 10.2.6 The Corona Discharge Pin …………………………………………………….. 169 10.3 The Electrospray Probe ……………………………………………………………………… 170 10.3.1 Replacement of the Stainless Steel Sample Capillary ………………… 171 10.4 The APcI Probe ………………………………………………………………………………… 172 10.4.1 Cleaning the Probe Tip ………………………………………………………….. 173 Table of Contents xiii 10.4.2 Replacing the Probe Tip Heater ……………………………………………… 174 10.4.3 Replacing the Fused Silica Capillary ………………………………………. 175 10.5 The Analyzer ……………………………………………………………………………………. 176 10.5.1 Removing the MS1 and Collision Cell Optical Bench Assembly … 177 10.5.2 Dismantling and Cleaning the Entrance Prefilter ……………………… 178 10.5.3 Cleaning the MS1 Analyzer Assembly ……………………………………. 178 10.5.4 Replacing the MS1 and Gas Cell Optical Bench Assembly ……….. 178 10.5.5 The MS2 Analyzer and Detector Assembly …………………………….. 179 10.6 Fault Finding ……………………………………………………………………………………. 179 10.6.1 No Beam ……………………………………………………………………………… 179 10.6.2 Unsteady Beam ……………………………………………………………………. 180 10.6.3 High Back Pressure ………………………………………………………………. 181 10.6.4 Loss of Sensitivity ……………………………………………………………….. 182 10.6.5 Incorrect Isotope Distributions ………………………………………………. 182 10.6.6 High Noise Levels ……………………………………………………………….. 182 10.6.7 Poor Analyzer Vacuum …………………………………………………………. 183 10.7 Cleaning Materials ……………………………………………………………………………. 184 10.8 Preventive Maintenance Check List…………………………………………………….. 184 10.8.1 Daily……………………………………………………………………………………. 185 10.8.2 Weekly ……………………………………………………………………………….. 185 10.8.3 Monthly ………………………………………………………………………………. 185 10.8.4 Four-Monthly ………………………………………………………………………. 185 Appendix A Reference Information ………………………………………………………………………. 187 A.1 Positive Ion ………………………………………………………………………………. 188 A.2 Negative Ion …………………………………………………………………………….. 190 A.3 Preparation of Calibration Solutions ………………………………………………. 192 xiv Table of Contents Appendix B Instrument Specifications …………………………………………………………………. 195 B.1 Room Location …………………………………………………………………………. 195 B.2 Environment …………………………………………………………………………….. 195 B.3 Water Supplies ………………………………………………………………………….. 196 B.4 Power Requirements ………………………………………………………………….. 197 B.5 Gases and Regulators …………………………………………………………………. 198 B.6 Exhaust Outlets …………………………………………………………………………. 199 B.7 Performance Specifications ………………………………………………………….. 199 List of Figures xv List of Figures 1-1 The Micromass Q-tof micro ……………………………………………………………. 5 1-2 Q-Tof micro Ion Optics…………………………………………………………………… 8 1-3 Mechanical Components – Internal View…………………………………………. 10 1-4 Rear View of Instrument……………………………………………………………….. 11 1-5 Q-Tof micro Vacuum System…………………………………………………………. 12 1-6 Front Panel………………………………………………………………………………….. 14 1-7 Rear Panel Connections ………………………………………………………………… 16 1-8 Rear Panel Outputs ………………………………………………………………………. 18 2-1 MCP Conditioning Dialog …………………………………………………………….. 23 2-2 Shutdown Page ……………………………………………………………………………. 30 2-3 Shutdown on Error Configuration Dialog ……………………………………….. 31 2-4 Configure Event In Dialog…………………………………………………………….. 32 2-5 Gas Threshold Dialog …………………………………………………………………… 33 2-6 Auto Control Tasks Page ………………………………………………………………. 33 2-7 Shutdown Startup Log ………………………………………………………………….. 36 2-1 Log Parameters Dialog …………………………………………………………………. 37 3-1 Electrospray Scheme…………………………………………………………………….. 39 3-2 Post Column Split ………………………………………………………………………… 42 3-3 Comparison of Normal and Megaflow Electrospray…………………………. 42 3-4 ESI Source ………………………………………………………………………………….. 43 3-5 Electrospray Tip…………………………………………………………………………… 45 3-6 Optimum Probe Position……………………………………………………………….. 46 3-7 Probe Adjustment ………………………………………………………………………… 46 4-1 The Nanoflow Interface ………………………………………………………………… 55 4-2 Nanoflow Electrospray Scheme……………………………………………………… 56 4-3 Electrospray Source Being Removed ……………………………………………… 57 xvi List of Figures 4-4 Nanoflow Source Without Cover……………………………………………………. 58 4-5 Nanoflow Source with Cover and End Flange …………………………………. 59 4-6 Nanoflow Camera and Microscope System……………………………………… 60 4-7 Nanovial Tip Position …………………………………………………………………… 62 4-8 Nano-LC Assembly ……………………………………………………………………… 64 5-1 Schematic Representation of APcI …………………………………………………. 67 5-2 Illustration of Probe Adjustment…………………………………………………….. 70 5-3 APcI Probe showing twin Thumb Nuts used for Removal…………………. 72 6-1 The Ion Optical System of the Q-Tof micro …………………………………….. 76 6-2 The QTof micro Tune Page……………………………………………………………. 77 6-3 The Customize Display Menu ……………………………………………………….. 79 6-4 The Customise Plot Appearance Dialog………………………………………….. 79 6-5 The Source Tuning Page……………………………………………………………….. 81 6-6 The Quadrupole Tuning Page ………………………………………………………… 83 6-7 The Time Of Flight Page ………………………………………………………………. 85 6-8 The TDC Settings Dialog ……………………………………………………………… 88 6-9 The Tune Page Acquisition Dialog…………………………………………………. 91 6-10 Combined Spectrum of Leucine Enkephalin Showing Peak Width at Half Height 92 7-1 TDC Settings Dialog…………………………………………………………………….. 95 7-2 The Tune Page Acquisition Dialog…………………………………………………. 97 7-3 Indicated Mass of Leucine Enkephalin prior to Lteff Correction………… 98 7-4 Indicated Mass of Leucine Enkephalin after Lteff Correction. …………… 99 7-5 The TOF Accurate Mass dialog……………………………………………………. 100 7-6 The TOF Spectrum Center Dialog………………………………………………… 101 7-7 Comparison of Centered Spectra With (top) and Without (bottom) Deadtime Correction 101 7-8 The Calibration Window……………………………………………………………… 102 7-9 The Display Calibration Graphs Dialog ………………………………………… 103 7-10 Calibration Window Showing Residual Errors……………………………….. 104 List of Figures xvii 7-11 The Calibration Parameters Dialog……………………………………………….. 105 7-12 The Accept Calibration Dialog …………………………………………………….. 105 7-13 Calibration Window Deadtime Distortion ……………………………………… 106 7-14 Same data as Figure 7-13 but with Np multiplier of 0.7…………………… 107 7-15 Two Spectra One (bottom) with no Deadtime Correction and the Other (top) with. 108 8-1 Tune Page Acquisition Dialog ……………………………………………………… 112 8-2 The Scan Report Dialog………………………………………………………………. 114 8-3 The Experiment Setup Editor ………………………………………………………. 116 8-4 The Solvent Delay Dialog……………………………………………………………. 119 8-5 The Analog Data Dialog ……………………………………………………………… 120 8-6 The TOFMS Scan Dialog ……………………………………………………………. 122 8-7 The MSMS Scan Dialog ……………………………………………………………… 124 8-8 Survey Scan Dialog: Qtof MicroSurvey Page ………………………………… 127 8-9 Survey Scan Dialog: MS to MSMS Page ………………………………………. 128 8-10 Survey Scan Dialog: MSMS to MS Page ………………………………………. 131 8-11 Survey Scan Dialog: MSMS Template Page ………………………………….. 132 8-12 Survey Scan Dialog: Include Masses Page…………………………………….. 133 8-13 Survey Scan Dialog: Collision Energy Page ………………………………….. 135 8-14 The CE Profile Dialog ………………………………………………………………… 136 8-15 The Modify Charge State Dialog………………………………………………….. 137 8-16 Survey Scan Dialog: Exclude Masses Page……………………………………. 138 9-1 Parent Scan Dialog: Parent Survey Page ……………………………………….. 140 9-2 Example of a Screen Capture……………………………………………………….. 142 9-3 Parent Scan Dialog: Neutral Loss Page …………………………………………. 143 9-4 Parent Scan Dialog: MSMS Template …………………………………………… 144 9-5 Parent Scan Dialog: MSMS to MS Page ……………………………………….. 148 9-6 Parent Scan Dialog: Include Page…………………………………………………. 149 9-7 Parent Scan Dialog: Exclude Dialog …………………………………………….. 151 9-8 Parent Scan Dialog: Collision Energy Page……………………………………. 152 xviii List of Figures 9-9 The CE Profile Dialog ………………………………………………………………… 153 9-10 The Modify Charge State Dialog………………………………………………….. 154 10-1 Rotary Pump ……………………………………………………………………………… 158 10-2 Removing The Source Enclosure …………………………………………………. 161 10-3 The Source, With Housing Removed ……………………………………………. 162 10-4 Removing the Cone ……………………………………………………………………. 164 10-5 Source Block and Extraction Cone Removed…………………………………. 165 10-6 Removing The RF Lens Assembly……………………………………………….. 167 10-7 The RF Lens Assembly……………………………………………………………….. 168 10-8 Removing the Stainless Steel Capillary form the Source …………………. 171 10-9 The APcI Probe Tip Heater………………………………………………………….. 174 10-10 Replacing the Fused Silica Capillary on the APcI probe………………….. 175 10-11 The Prefilter and Main Analyzer of the Q-Tof micro………………………. 176 1 Preface The Micromass QTof micro Mass Spectrometer is intended for a wide variety of users whose familiarity with Mass Spectrometers, computers and software ranges from novice to expert. This guide describes the basics of how to Startup the instrument, obtain an Ion Beam, Calibrate and Acquire Data using MassLynx Software, and maintain the instrument. Organization This guide contains the following: Chapter 1 gives a brief description and overview of the instrument Chapter 2 describes the routine procedures that are required to Startup and Shutdown the Instrument Chapter 3 describes the the Electrospray Interface. Chapter 4 describes the Nanoflow Interface. Chapter 5 describes the APcI Interface. Chapter 6 describes the Tuning page and how to Obtain an Ion Beam. Chapter 7 describes how to calibrate the instrument. Chapter 8 describes how to Acquire data from the MassLynx sample list and how to set up a method. Chapter 9 describes a Parent Ion Discovery experiment. Chapter 10 describes Maintenance and Fault Finding for the instrument. Related Documentation Waters Licenses, Warranties, and Support: Provides software license and warranty information, describes training and extended support, and tells how Waters handles shipments, damages, claims, and returns. Online Documentation MassLynx Help: Describes all MassLynx windows, menus, menu selections, and dialog boxes for the base software and software options. Also included are help Files 2 on Inlet Control, Interfacing, Security and any application software that may have been purchased. MassLynx ReadMe File: Describes product features and enhancements, helpful tips, installation and/or configuration considerations, and changes since the previous version. Printed Documentation for Base Product Instrument User’s Guides: Provides an introduction to the running and maintenance of the Instrument and also basic instructions on how to acquire data and calibrate the instrument. MassLynx User’s Guide: Provides a comprehensive introduction to the MassLynx software. Describes the basics of how to use MassLynx software to acquire data develop an acquisition method, review and process results, and print a report. MassLynx Interfacing Guide: Provides information on how to interface MassLynx with other Software applications. MassLynx Inlet Control Guide: Provides information on how to install and run Autosamplers, LC and GC systems, UV detectors using MassLynx. MassLynx Security User’s Guide: Describes how to add security to your MassLynx system. Printed Documentation for Software Options QuanLynx User’s Guide: Describes the procedures for installing, configuring and using QuanLynx Software. OpenLynx User’s Guide: Describes the procedures for installing, configuring and using OpenLynx Software. FractionLynx User’s Guide: Describes the procedures for installing, configuring and using FractionLynx Software. MetaboLynx User’s Guide: Describes the procedures for installing, configuring and using MetaboLynx Software. BioLynx and ProteinLynx User’s Guide: Describes the procedures for installing, configuring and using BioLynx and ProteinLynx Software. MicrobeLynx User’s Guide: Describes the procedures for installing, configuring and using MicrobeLynx Software. 3 NeoLynx User’s Guide: Describes the procedures for installing, configuring and using NeoLynx Software. TargetLynx User’s Guide: Describes the procedures for installing, configuring and using TargetLynx Software. GCLynx User’s Guide: Describes the procedures for installing, configuring and using GCLynx Software. Documentation on the Web Related product information and documentation can be found on the World Wide Web. Our address is http://www.waters.com/micromass. Documentation Conventions The following conventions can be used in this guide: Convention Usage Bold Bold indicates user action such as keys to press, menu selections, and commands. For example, “Click Next to go to the next page.” Italic Italic indicates information that you supply such as variables. It also indicates emphasis and document titles. For example, “Replace file_name with the actual name of your file.” Courier Courier indicates examples of source code and system output. For example, “The SVRMGR> prompt appears.” Courier Bold Courier bold indicates characters that you type or keys you press in examples of source code. For example, “At the LSNRCTL> prompt, enter set password oracle to access Oracle.” Keys The word key refers to a computer key on the keypad or keyboard. Screen keys refer to the keys on the instrument located immediately below the screen. For example, “The A/B screen key on the 2414 Detector displays the selected channel.” … Three periods indicate that more of the same type of item can optionally follow. For example, “You can store filename1, filename2, … in each folder.” > A right arrow between menu options indicates you should choose each option in sequence. For example, “Select File > Exit” means you should select File from the menu bar, then select Exit from the File menu. 4 Notes Notes call out information that is helpful to the operator. For example: Note: Record your result before you proceed to the next step. Attentions Attentions provide information about preventing damage to the system or equipment. For example: Cautions Cautions provide information essential to the safety of the operator. For example: Attention: To avoid damaging the detector flow cell, do not touch the flow cell window. Caution: To avoid burns, turn off the lamp at least 30 minutes before removing it for replacement or adjustment. Caution: To avoid electrical shock and injury, unplug the power cord before performing maintenance procedures. Caution: To avoid chemical or electrical hazards, observe safe laboratory practices when operating the system. Caution: Operating the source without the source enclosure will result in solvent vapor escape. Caution: Strong acid causes burns. Carry out this procedure in a fume cupboard using protective equipment. Caution: Cleaning the source requires the use of solvents and chemicals which may be flammable. 5 1 Chapter 1 Overview This chapter gives a brief description of the following • The Micromass Q-Tof micro Section 1.1 • The Ion Optics Section 1.2 • The Internal Layout Section 1.3 • The Vacuum System Section 1.4 • Front and Rear Panel Connections Section 1.5 and Section 1.6 • The MassLynx Data System Section 1.7 Figure 1-1 The Micromass Q-tof micro 6 Overview 1 1.1 Instrument Description The Q-Tof micro hybrid quadrupole time of flight mass spectrometer is available with electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APcI). Q-Tof micro utilises a high performance, research grade quadrupole mass analyser, incorporating a prefilter assembly to protect the main analyser from contaminating deposits, and an orthogonal acceleration time of flight (TOF) mass spectrometer. A hexapole collision cell, between the two mass analysers, can be used to induce fragmentation to assist in structural investigations. Ions emerging from the second mass analyser are detected by the microchannel plate detector and ion counting system. A PC computer runs the MassLynx NT software system to control Q-Tof micro, and to acquire and process data. 1.1.1 Ionisation Techniques Using the Micromass Z-spray atmospheric pressure ionisation (API) source, two techniques are available. 1.1.2 Atmospheric Pressure Chemical Ionisation Atmospheric pressure chemical ionisation (APcI) generally produces protonated or deprotonated molecular ions from the sample via a proton transfer (positive ions) or proton abstraction (negative ions) mechanism. The sample is vapourised in a heated nebuliser before emerging into a plasma consisting of solvent ions formed within the atmospheric source by a corona discharge. Proton transfer or abstraction then takes place between the solvent ions and the sample. Eluent flows up to 2 millilitres/minute can be accommodated without splitting the flow. 1.1.3 Electrospray Electrospray ionisation (ESI) takes place as a result of imparting a strong electrical charge to the eluent as it emerges from the nebuliser. An aerosol of charged droplets emerges from the nebuliser. These undergo a reduction in size by solvent evaporation until they have attained a sufficient charge density to allow sample ions to be ejected from the surface of the droplet (“ion evaporation”). Instrument Description 7 1 A characteristic of ESI spectra is that ions may be singly or multiply charged. Since the mass spectrometer filters ions according to their mass-to-charge ratio ( ), compounds of high molecular weight can be determined if multiply charged ions are formed. Eluent flows up to 1 ml/min can be accommodated although it is often preferable with electrospray ionisation to split the flow such that 5-50 µl/min of eluent enters the mass spectrometer. 1.1.4 Nanoflow Electrospray The optional nanoflow interface allows electrospray ionisation to be performed in the flow rate range 5 to 1000 nanolitres per minute. For a given sample concentration, the ion currents observed in nanoflow are comparable to those seen in normal flow rate electrospray. Great sensitivity gains are therefore observed when similar scan parameters are used, due to the great reductions in sample consumption. 8 Overview 1 1.2 Ion Optics Figure 1-2 Q-Tof micro Ion Optics The principal components of the ion optical system are shown in Figure 1-2. Ions generated in the Z-spray source are transferred to the quadrupole analyser MS1 via the independently pumped RF lens. After leaving the quadrupole analyser the ions flow into the orthogonal time of flight analyser MS2. The ion beam is focused into the pusher by the acceleration, focus, steer and tube lenses. The pusher then pulses a section of the beam towards the reflectron, which then reflects ions back to the detector. As ions travel from the pusher to the detector they are separated in mass according to their flight times, with ions of the highest mass to charge ratio ( ) arriving later. Probe MS1 (Quadrupole MS) MS2 (TOF MS) MCP Detector Pusher Z-spray Ion Source RF Lens Hexapole Transfer Lens Quadrupole Analyser Hexapole Collision Cell Reflectron Internal Layout 9 1 The pusher may be operated at repetition frequencies of up to 30 kHz, resulting in a full spectrum being recorded by the detector every 33 microseconds. Each spectrum is summed in the histogram memory of the time to digital converter until the histogrammed spectrum is transferred to the host PC. If the user has requested an acquisition rate of 1 spectrum/second, each spectrum viewed on the host PC will be the result of summing up to 30,000 individual spectra recorded at the detector. Unlike scanning instruments, the TOF performs parallel detection of all masses within the spectrum at very high sensitivity and acquisition rates. This characteristic is of particular advantage when the instrument is coupled to fast chromatography, since each spectrum is representative of the sample composition at that point in time, irrespective of how rapidly the sample composition is changing. 1.3 Internal Layout Caution: The covers should not be removed without first isolating the instrument at the electricity supply. Attention: The internal layout is shown in the following diagrams for information only, and does not imply that labelled components are user-serviceable. 10 Overview 1 1.3.1 Mechanical Components Figure 1-3 Mechanical Components – Internal View. The main internal mechanical components of the instrument are: • The source housing, containing the RF (hexapole) lens. • The MS1 analyser housing, containing the quadrupole analyser, hexapole collision cell and hexapole transfer lens • The TOF analyser housing, containing the pusher, detector and reflectron assemblies. • One 250 litre/second turbomolecular pump, plus one split-flow turbomolecular pump. • Two active inverted magnetron (Penning) gauges and two Pirani gauges. 1.3.2 Electrical Components The main electronics unit is located in the lower rear section of the instrument. This contains: Osmc Osmc DESOLVATION GAS CAPILLARY CORONA NANOFLOW PROBES NEBULISER GAS LOAD INJECT GAS CELL NANOFLOW RF Generator PSU Z-spray Source Turbomolecular Pumps Internal Layout 11 1 • High voltage power supplies. • These supply the probe or corona, reflectron, TOF flight tube and lens circuits. • Low voltage power supplies. • These supply the PCBs, high voltage supplies and turbomolecular pumps. • Main PCBs. • For communications, lenses and quadrupole control. Figure 1-4 Rear View of Instrument Main PCBs Flight Tube High Voltage PSU 12 Overview 1 1.4 The Vacuum System Figure 1-5 Q-Tof micro Vacuum System 1.4.1 Fine Pumping Q-Tof micro is equipped with three water cooled turbomolecular pumps, providing independent fine pumping of the source hexapole, quadrupole and TOF analysers. Details of the operation and maintenance of the pumps can be found in the manufacturer’s manuals provided. TOF Analyser Quadrupole Analyser Automatic Vent (to N ) Exhaust 2 Oil Mist Filter Rotary Pump Pirani Gauge Active Inverted Magnetron Gauge Pirani Gauge Turbomolecular Pump Split Flow Turbomolecular Pump CID Gas Solenoid Valve Speedivalve Probe Z-spray Ion Source Gas Cell The Vacuum System 13 1 1.4.2 Rotary Pumping Source pumping and turbomolecular pump backing is by a direct drive rotary pump. The rotary pump is situated at the front of the instrument. Details of the operation and maintenance of the pump can be found in the manufacturer’s manual provided. 1.4.3 Pressure Measurement The backing pressure is monitored by an active Pirani gauge. The analyser and TOF pressures are monitored by active inverted magnetron (Penning) gauges. These gauges act as vacuum switches, switching the instrument out of Operate mode if the pressure is too high. Pressure readings may be displayed on the MassLynx NT tune page. The analyser Penning gauge only comes on when the vacuum display window is open. At other times the gauge is off. The analyser Pirani gauge is used when the diaply is off, though no pressures are shown. 1.4.4 Vacuum Protection The vacuum system is fully interlocked to provide adequate protection in the event of: • a fault in the vacuum system. • a failure of the power supply. • a failure of the water supply. • a vacuum leak. 14 Overview 1 1.5 Front Panel Connections Figure 1-6 Front Panel 1.5.1 Desolvation Gas and Probe Nebuliser Gas The PTFE gas lines for the Desolvation Gas and probe Nebuliser Gas are connected to the front of the instrument using threaded metal fittings. Cone Gas is connected internally. 1.5.2 High Voltage The electrical connection for the ESI capillary or the APcI corona discharge pin is via the coaxial high voltage connector. This socket is labeled Capillary / Corona. 1.5.3 Heaters The electrical connection for the APcI probe or the ESI desolvation heater is via the multi-way connector labeled Probes. This is removed from the front panel by pulling on the metal sleeve of the plug. Both the electrospray desolvation heater and the APcI probe heater use this connector. The power for the source block heater is permanently connected. As a consequence, the source block assembly is usually very hot, and should not be touched. Front Panel Connections 15 1 1.5.4 Front Panel Controls and Indicators Status Display The display on the front panel of the instrument consists of two 3-colour light emitting diodes (LEDs). The display generated by the Pump LED is dependent on the vacuum status of the instrument. The Operate LED depends on both the vacuum status and whether the operate mode has been selected from the Data System. Further information is included in Automatic Pumping and Vacuum Protection (see Routine Procedures). Divert / Injection Valve The divert / injection valve may be used in several ways depending on the plumbing arrangement: • As an injection valve, with the needle port and sample loop fitted. • As a divert valve, to switch the flow of solvent during a LC run. • As a switching valve to switch, for example, between a LC system and a syringe pump containing calibrant. This valve is pneumatically operated, using the same nitrogen supply as the rest of the instrument. The two switches marked Load and Inject enable the user to control the valve when making loop injections at the instrument. 16 Overview 1 1.6 Rear Panel Connections Figure 1-7 Rear Panel Connections 1.6.1 Water Water is used to cool the turbomolecular pumps. 1.6.2 Nitrogen Gas In The nitrogen supply (100 psi, 7 bar) should be connected to the Nitrogen Gas In push-in connector using 6mm PTFE tubing. If necessary this tubing can be connected to ¼ inch tubing using standard ¼ inch fittings. Caution: Use only PTFE tubing or clean metal tubing to connect between the nitrogen supply and the instrument. The use of other types of plastic tubing will result in chemical contamination of the source. Rotary Pump Power Supply Inlet Water In Collision Gas In Nitrogen In Nitrogen Out PC Port Power In Network Connection Water Out Rear Panel Connections 17 1 1.6.3 Exhausts The exhaust from the rotary pump should be vented to atmosphere outside the laboratory. The gas exhaust, which also contains solvent vapours, should be vented via a separate fume hood, industrial vent or cold trap. The gas exhaust should be connected using 10mm plastic tubing connected to the push-in fitting. Caution: Do not connect these two exhaust lines together as, in the event of an instrument failure, rotary pump exhaust could be admitted into the source chamber producing severe contamination. 1.6.4 Supply Inlet The mains power cord should be wired to a 230V mains outlet using a suitable plug, or to a transformer. For plugs with an integral fuse, the fuse should be rated at 13 amps (UK only). 1.6.5 Electronics This circuit breaker switches power to the electronics. In the event of the instrument drawing more than the rated current, the circuit breaker will trip. 1.6.6 Rotary Pump This circuit breaker switches power to the rotary and turbomolecular pumps. In the event of the pumps drawing more than the rated current, it will trip. 1.6.7 Event Out Four outputs, Out 1 to Out 4 (Figure 1-8), are provided to allow various peripherals to be connected to the instrument. Switches S1 to S4 allow each output to be set to be either a contact closure (upper position) or a voltage output (lower position). Out 1 and Out 2, when set to voltage output, each have an output of 5 volts. The voltage output of both Out 3 and Out 4 is 24 volts. During a sample run an event output may be configured to close between acquisitions and is used typically to enable an external device to inject the next sample. 18 Overview 1 1.6.8 Contact Closure In In 1 and In 2 inputs are provided ((Figure 1-8) to allow an external device to start sample acquisition once the device has performed its function (typically sample injection). 1.6.9 Analog Channels Four analog channel (Figure 1-8) inputs are available, for acquiring simultaneous data such as a UV detector output. The input differential voltage must not exceed one volt. Figure 1-8 Rear Panel Outputs 1.7 MassLynx Data System A PC computer runs the MassLynx NT software system to control Q-Tof micro, and to acquire and manipulate data from it. A high resolution colour monitor is also supplied. Interaction with MassLynx NT is via the mouse and keyboard using menu-driven commands. Printing, file management and other routine procedures are performed using the appropriate Windows NT modules. EVENT OUT C ON TAC T C LO SU RE CONTACT CLOSURE IN P U TS AN ALOG UE INPUTS IN 1 4 1Vmax 24V MUX IN OUT 24V 5V 5V 4 3 2 1 2 1Vmax 1 1Vmax 3 1Vmax IN 2 MassLynx Data System 19 1 1.7.1 Software The following software packages are supplied with Q-Tof micro: • MassLynx NT. • DataBridge, a utility to convert other format data files into MassLynx format. • Microsoft Windows NT/2000/XP graphical environment. • Mouse configuration. A range of optional software modules for different applications is also available. The MassLynx NT User’s Guide describes the many facilities of the Micromass software. Documentation for the other software is also supplied. 20 Overview Start Up Following a Complete Shutdown 21 2 Chapter 2 Routine Procedures The following Routine Procedures are described in this chapter: • Section 2.1, Start Up Following a Complete Shutdown • Section 2.2, Start Up Following Overnight Shutdown • Section 2.3, Automatic Startup and Shutdown 2.1 Start Up Following a Complete Shutdown 2.1.1 Preparation If the instrument has been unused for a lengthy period of time, proceed as follows: 1. Check the level of oil in the rotary pump sight glass. Refill or replenish as necessary as described in the pump manufacturer’s literature. 2. Connect a supply of dry, high purity nitrogen to the connector on the service panel at the rear of the instrument. Adjust the outlet pressure to 7 bar (100 psi). 3. Connect the water supply to the connections at the rear of the instrument. 4. Check that the rotary pump exhaust is connected to a suitable vent. 5. Check that the instrument, data system and other peripheral devices (LC equipment, printer etc.) are connected to suitable mains supplies. 6. Check that the etherlink connection is made between the control PC and the instrument PC. 7. Switch on the host PC. Log on to Windows NT and wait for the system to boot up before the Q-Tof micro is switched on. 8. Switch on the mains to the mass spectrometer using the two circuit breakers situated on the service panel at the rear of the instrument. Attention: Do not connect the two exhaust lines together. In the event of an instrument failure, rotary pump exhaust could be admitted into the source chamber, producing severe contamination 22 Routine Procedures 2 9. Switch on the embedded PC using the switch at the rear of the instrument. 10. Log on to Micromass account (password analysis). Note: Windows NT and MassLynx are configured to prevent unauthorized access. 11. On the host PC, select Instrument >MS Tune from the MassLynx Shortcut bar. This will invoke the Instrument Tune Page. 2.1.2 Pumping 1. Select Vacuum from the menu bar at the top of the tune page. 2. Click on Pump. 3. The rotary pump and the turbomolecular pumps start simultaneously. 4. The Vacuum LED on the front of the instrument shows amber as the system pumps down. When the system has reached operating vacuum the Vacuum LED changes to a steady green. 5. If the rotary pump oil has been changed or replenished, open the gas ballast valve on the rotary pump. See the pump manufacturer’s literature for details. Rotary pumps are normally noticeably louder when running under gas ballast. 6. If opened, close the gas ballast valve when the rotary pump has run under gas ballast for 30 minutes. Attention: To minimize wear to the lubricated components of the rotary pump, the manufacturers recommend that the pump is not started when the oil temperature is below 12°C. Start Up Following a Complete Shutdown 23 2 2.1.3 MCP Detector Conditioning Figure 2-1 MCP Conditioning Dialog The MCP detector must be conditioned before use, by gradually increasing the applied voltage over a long time period. This is necessary to allow escape of all absorbed water from within the microchannels. Under normal operation the analyzer automatically vents to dry nitrogen. However, if the nitrogen supply was not connected to the instrument when last vented, or if the instrument has been left vented for more than one day, a significant amount of water vapor may have entered the analyzer. Under these circumstances it is good practice to allow the instrument to pump for 12 hours before commencing the conditioning process. In all cases, the TOF pressure must be 2e-6 mbar prior to commencing MCP conditioning. MCP conditioning should be repeated after every instrument venting. Note: It is not necessary to recondition the detector if the instrument has been left out of the operate mode while still under vacuum. Note: During routine cleaning of the source sample cone, the source isolation valve is closed in order to maintain analyzer vacuum. It is not, therefore, necessary to recondition the detector after this procedure. The procedure for MCP conditioning is as follows: 1. Ensure that the TOF pressure is 2e-6 mbar. 2. Check that the MCP Detector voltage is set to zero on the tune page. 3. Switch the instrument into Operate. 24 Routine Procedures 2 4. Select Options > MCP Conditioning to access the MCP conditioning program (Figure 2-1). 5. Set Start to 100V, Stop to 2700V, Duration to 600 minutes and Step to 5 minutes. 6. A ‘quick condition’ may be performed following brief venting, after source cleaning for example. 7. Set Start to 100V, Stop to 2700V, Duration to 180 minutes and Step to 1 minute. 2.1.4 Instrument Warm-up Switch the instrument into the operate mode by selecting Operate on the MassLynx tune page. For the best mass accuracy to be obtained the instrument temperature must be stabilized for a minimum of two hours after switching into operate. Note: Leaving the instrument continuously in operate does not shorten the detector lifetime. It is recommended that the instrument is left in operate at all times (except of course during maintenance procedures) in order to reduce mass scale drifts due to temperature changes. Switching the instrument out of operate mode overnight is not necessary. 2.1.5 Using the Instrument The Q-Tof micro is now almost ready to use. To complete the start up procedure and prepare for running samples, follow the instructions in Start Up Following Overnight Shutdown in the following pages. 2.2 Start Up Following Overnight Shutdown The instrument will have been left in the operate mode under vacuum. It is recommended that the data system is left on overnight. However, if the data system has been switched off, switch it on as described in the preceding section. Attention: Failure to follow the recommended MCP conditioning procedure can severely reduce detector lifetime. Start Up Following Overnight Shutdown 25 2 2.2.1 Preparation for Electrospray Operation If the corona discharge pin is fitted, proceed as follows: 1. Deselect Operate from the tune page to put the instrument into standby mode. 2. Disconnect the gas and electrical connections from the front panel. 3. Unscrew the probe thumb nuts and remove the probe. 4. Undo the three thumb screws and remove the probe adjustment flange and glass tube. 5. Disconnect the APcI high voltage cable from the socket positioned at the bottom right corner of the source flange. 6. Remove the corona discharge pin from its mounting contact, and fit the blanking plug. 7. Replace the glass tube and adjustment flange. 8. Ensure that the source enclosure is in place. Note: The Z-spray source enclosure consists of the glass tube and the probe adjustment flange. 9. With the corona discharge pin removed, the plug fitted and the source enclosure in place, proceed as follows: 10. Connect the source’s gas line to Desolvation Gas on the front panel. Tighten the nut to ensure a good seal. 11. Check that the lead of the probe adjustment flange is plugged into the socket labelled Probes on the front panel. 12. Connect the electrospray probe’s gas line to Nebuliser Gas on the front panel. 13. Connect the liquid flow of a LC system or syringe pump to the probe. 14. Insert the probe into the source and tighten the two thumb nuts to secure the probe firmly. Caution: The ion source block can be heated to temperatures of 150°C, and will be maintained at the set temperature when the source enclosure is removed. Touching the ion block when hot may cause burns to the operator Caution: Operating the source without the source enclosure will result in solvent vapor escape and the exposure of hot surfaces and high voltages. 26 Routine Procedures 2 15. Plug the probe lead into Capillary / Corona on the front panel. 16. If necessary, change the ionization mode using the Ion Mode command. 17. Set Source Block Temp to 100°C and Desolvation Temp to 120°C. 2.2.2 Preparation for APcI Operation If the corona discharge pin is not fitted, proceed as follows: 1. Deselect Operate from the tune page to put the instrument into standby mode. 2. Disconnect the gas and electrical connections from the front panel. 3. Unscrew the probe thumb nuts and remove the probe. 4. After a period of operation at high flow rates, allow the glass source enclosure to cool before removal. 5. Undo the three thumb screws and remove the probe adjustment flange and glass tube. 6. Remove the blanking plug from the discharge pin mounting contact and fit the corona discharge pin, ensuring that the tip is in line with the tip of the sample cone. 7. Connect the APcI high voltage cable between Capillary / Corona and the socket positioned at the bottom left corner of the source flange. 8. Replace the glass tube, adjustment flange and moulded cover. 9. With the corona discharge pin fitted and the source enclosure in place, proceed as follows: 10. Insert the APcI probe into the source and tighten up the two thumb screws. 11. If necessary, change the ionization mode using the Ion Mode command. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. Attention: The ion source block can be heated to temperatures of 150°C, and will be maintained at the set temperature when the source enclosure is removed. Touching the ion block when hot may cause burns to the operator. Caution: Operating the source without the source enclosure will result in solvent vapor escape and the exposure of hot surfaces and high voltages. Start Up Following Overnight Shutdown 27 2 12. Set Source Temp to 150°C. Note: Do not start the liquid flow until the gas flow and probe heater are switched on with the probe inserted. 2.2.3 Transient Pressure Trip The transient trip is designed to protect the instrument from potentially damaging pressure surges and operates routinely whenever the pressure rises. Should the vacuum gauge(s) detect a pressure surge above the preset trip level (normally set at 1e-5 mbar by software) the following events occur: • The green Pump lamp becomes amber. • If in the operate mode, the system turns off the critical source, analyzer and detector voltages, and the green Operate lamp becomes amber. • Acquisition continues though, of course, no real data are recorded. When the vacuum recovers: • The amber Pump lamp becomes green. • If previously in the operate mode, voltages are restored and Operate reverts to green. The period during which the trip was operative will appear in a raw total ion chromatogram as a period of reduced baseline noise. Further deterioration of the system pressures results in a “vacuum fault” condition and the system is shut down (see below). 2.2.4 Power Failure In the event of an unexpected failure of the electrical supply the instrument is vented safely. If power is unlikely to be restored quickly, follow the shutdown procedure described later in this chapter. When power is restored follow the startup procedure. Should the power fail and then be restored while the instrument is unattended, the system will continue to vent, and will require to be pumped down in accordance with the start-up procedure. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. 28 Routine Procedures 2 2.2.5 Nitrogen Supply Replacement of nitrogen cylinders should be conducted in accordance with the operation, handling and storage instructions provided by the local gas supplier. Toggle the API gas button to Off, to close the nitrogen inlet valve prior to disconnecting the supply. Set the nitrogen inlet pressure to 7 bar (100 psi). 2.3 Automatic Startup and Shutdown MassLynx comes with automatic Startup and Shutdown files. They are found in the C:\MassLynx\Shutdown directory and are called ShutDownxxx.acl and StartUpxxx.acl where xxx refers to the instrument configuration. E.g. ShutDownESI_ACE.acl for an instrument configured as an ACE system. 2.3.1 The Shutdown Editor The shutdown editor allows the automatic startup and shutdown procedures to be modified or new procedures to be created. These can be run automatically before or after a batch if the relevant boxes are checked in the Batch Control frame of the Shutdown Page (Section 2.3.3). Select Edit Shutdown or Startup from the MassLynx Instrument Shortcut Bar. This Invokes the Shutdown Editor which has two tabbed pages, the Shutdown Page (described in Section 2.3.3 on page 29) and the Auto Control Tasks Page (described in Section 2.3.4 on page 33) Attention: Under no circumstances should the nitrogen pressure exceed 10 bar (140 psi). Automatic Startup and Shutdown 29 2 2.3.2 The Shutdown Editor Toolbar 2.3.3 Shutdown Page Select Edit Shutdown or Startup from the MassLynx Instrument Shortcut Bar. By default the Shutdown Page is displayed (Figure 2-2) with the following parameters. Toolbar Button Menu Equivalent Purpose File… New Create a new Startup or Shutdown file File… Open Open an existing Startup or Shutdown file File… Save or Save As Save a Startup or Shutdown file File… Print Print a Startup or Shutdown file Control List..Run List Run a Startup or Shutdown file Control List…Stop List Stop a Startup or Shutdown file Enable startup before batch Enables/disables the running of a task file before the start of a batch of samples. Startup Enabled will appear on the right of the Status bar on the bottom of the MassLynx window when checked. Startup file The file name of the task file that is run before the start of a batch. Browse startup file Brings up a file dialog allowing a task file to be selected for the startup before batch procedure. Enable shutdown after batch Enables/disables the running of a task file after the end of a batch of samples. Shutdown Enabled will appear on the right of the Status bar on the bottom of the MassLynx window when checked. 30 Routine Procedures 2 Figure 2-2 Shutdown Page Configure Shutdown on Error Clicking on the Configure Error Shutdown button displays the following dialog. Shutdown file The file name of the task file that is run after the end of a batch. Browse shutdown file Brings up a file dialog allowing a task file to be selected for the shutdown after batch procedure. Shutdown Time This is the delay (in minutes) between the batch finishing and the shutdown procedure initiating. Shutdown On Error This allows shutdown on error to be enabled/disabled and to determine whether the shutdown tasks should be initiated immediately, or after the time entered in the Shutdown Time edit box. Configure Error Shutdown Brings up the Shutdown on Error Configuration dialog (see Section on page 30). Optimization Check this box to optimize the procedure. E-mail on Shutdown Check box and enter the e-mail address for shutdown information to be sent. Automatic Startup and Shutdown 31 2 Figure 2-3 Shutdown on Error Configuration Dialog Configure Contact Closures Clicking on the Configure CCs displays the following dialog. MS error Enables/disables running a task file when an MS error occurs. MS error shutdown file The task file to run on an MS error. MS error browse file Allows user to browse for task files. MS Comms Error Enables/Disables running task file when MS comms error occurs MS comms error shutdown file The task file to run on an MS comms error. Inlet fatal error Enables/disables running a task file when a LC error occurs. Inlet error shutdown file The task file to run when a LC error occurs. Inlet error browse file Allows user to browse for task files. Ext. device error Enables/disables running a task file when an external device error occurs. Ext. device shutdown file The task file to run when an external device error occurs. Ext. device browse file Allows user to browse for task files. Gas Threshold Invokes the Gas Threshold dialog (see Section on page 32) Configure CCs Invokes the Configure Event In dialog (see Section on page 31). 32 Routine Procedures 2 Figure 2-4 Configure Event In Dialog This window is used to configure the Event In contact closures on the back of the MS. These can be used to detect errors in external devices enabling the External device error flag to be set. Only contact closures not used to signal the completion of an injection, or not used by MUX systems, are enabled. Each of the CCs available has the following controls. Gas Thresholds Clicking on the Gas Thresholds button displays the following dialog. Event In Number Relates to the Event In number on the rear of the MS. Availability This can either be ‘Used By Inlet’ , ’Available’ , ‘Used by MUX’ or ‘Not Configured’. The controls are only enabled if the CC is ‘Available’. Use For Ext. Dev. Error Enables/disables the use of this contact closure to signal an error in an external device. State When in Error Determines what state the CC will be in when an error is present in an external device. Automatic Startup and Shutdown 33 2 Figure 2-5 Gas Threshold Dialog Clicking Gas Thresholds on the Configure Shutdown on Error dialog (Figure 2-3) invokes the Gas Threshold dialog; an MS error is flagged if the source gas flow rate falls below the value entered in the Low Threshold… (L/Hr) text box. Note: The Gas Thresholds button is only available when the MS error option is selected. 2.3.4 The Auto Control Tasks Page Figure 2-6 Auto Control Tasks Page Task This is a dropdown list box with all the available tasks. Pre-Delay This is the length of time that will elapse before the current task is performed 34 Routine Procedures 2 To Add a Task 1. Select a task from the dropdown Task list box. 2. Enter the required parameters. 3. Press the add button. Note: If this is a new task timetable the task will be added to the end of the list. If a task has been inserted into the task timetable then all subsequent tasks will be added after the inserted task. To add a task to the end of the timetable after inserting a task, double click below the last entry in the timetable and then add the new task. To Insert a Task 1. Click on the entry in the task timetable before which you want to insert the new task. 2. Select a task from the dropdown Task list box. 3. Enter the required parameters. 4. Press the add button. The task will be inserted before the selected entry. To Modify a Task 1. Click on the entry in the task timetable. The details for the task will be displayed in the fields on the left of the screen. 2. Change the required parameters. 3. Press the modify button. The details will change in the task timetable. To Delete a Task 1. Click on the entry in the task timetable. The details for the task will be displayed in the fields on the left of the screen. Post-Delay This is the length of time that will elapse after the current task has been completed and before the next task is started. E.g. a Post delay of 60s, in the Tune File task above, means that there will be a delay of 60 seconds before the next task is started, to allow the machine to stabilize with the new tune page settings. Ion Mode This is a dropdown list box with all the available ionization modes. File Name This is the name of the Tune file to be used. The file name can be typed in, including the full path name, or selected from the browser displayed when the Browse button is pressed. Automatic Startup and Shutdown 35 2 2. Press the add button. The task selected will be deleted from the task timetable. To Delete All Tasks Press the add button. All tasks will be deleted from the task timetable. To Change the Width of a Column The width of the columns can be changed, by positioning the mouse pointer on the heading between two columns until the symbol appears, and then click and drag until the column is the required width. Saving/Loading Startup and Shutdown Files To Open a Startup or Shutdown file 1. Press or select Open from the File menu. This displays the Open file dialog. 2. Select a data file and press the Open button. To Save a Startup or Shutdown file 1. Press or select Save or Save As from the File menu. If this is a new file, or the Save As option has been selected, the Save As dialog is displayed 2. Type a name into the File Name box and press the Save button. Printing Startup and Shutdown Files 1. Press or select Print from the File menu. This displays the Print dialog. 2. Select the printer, print range and number of copies and press the OK button. Creating Startup and Shutdown Files Press or select New from the File menu. Running Startup and Shutdown Files If Startup or Shutdown is selected from the MassLynx Short cut bar or from the Shutdown editor Control List menu then the automatic startup and shutdown files are run. To Run a Different Startup or Shutdown file: – 1. Open the required file in the Shutdown editor and press the toolbar button or select Run List from the Shutdown editor Control List menu. 36 Routine Procedures 2. Press the toolbar button or select Stop List from the Shutdown editor Control List menu if you wish to stop running this file. Alternatively if the Enable startup before batch or Enable shutdown after batch options are checked on the Shutdown Page (Section 2.3.3) the files will be run before or after a Sample List run. 2.3.1 Shutdown Log Figure 2-7 Shutdown Startup Log Shutdown / Startup Log The Shutdown / Startup Log keeps a record of the most recent startups and shutdowns. Select Shutdown Log > Recent Shutdowns and Startups invokes the Shutdown Startup Log (Figure 2-7). Selecting the most Recent Shutdowns and Startups in the top pane will show the tasks carried out in the bottom pane. Automatic Startup and Shutdown 37 2 Log Parameters Figure 2-1 Log Parameters Dialog Selecting Shutdown Log > Log Parameters from the main menu bar invokes the Shutdown Log Parameters dialog. The number of startups and shutdowns recorded in the Startup / Shutdown Log can be altered by changing the number in the text box. 38 Routine Procedures Introduction 39 3 Chapter 3 Electrospray 3.1 Introduction Figure 3-1 Electrospray Scheme The ESI interface consists of the standard Z-spray source fitted with an electrospray probe. See the following chapter for additional information concerning the optional nanoflow interface. Mobile phase from the LC column or infusion pump enters through the probe and is pneumatically converted to an electrostatically charged aerosol spray. The solvent is evaporated from the spray by means of the desolvation heater. The resulting analyte and solvent ions are then drawn through the sample cone aperture into the ion block, from where they are then extracted into the analyzer. The electrospray ionization technique allows rapid, accurate and sensitive analysis of a wide range of analytes from low molecular weight (less than 200 Da) polar compounds to biopolymers larger than 100 kDa. Sample Probe Nebuliser Gas Desolvation Gas Source Enclosure Isolation Valve Sample Cone Extraction Cone Rotary Pump Turbomolecular Pumps Analyser RF Lens Cleanable Baffle Cone Gas Exhaust Liner Exhaust Purge Gas 40 Electrospray 3 Generally, compounds of less than 1000 Da produce singly charged protonated molecules ([M+H]+) in positive ion mode. Likewise, these low molecular weight analytes yield ([M-H]–) ions in negative ion mode, although this is dependent upon compound structure. High mass biopolymers, for example peptides, proteins and oligonucleotides, produce a series of multiply charged ions. The acquired data can be transformed by the data system to give a molecular weight profile of the biopolymer. The source can be tuned to fragment ions within the ion block. This can provide valuable structural information for low molecular weight analytes. The most common methods of delivering sample to the electrospray source are: Syringe Pump and Injection Valve A flow of mobile phase solvent passes through an injection valve to the electrospray source. This is continuous until the pump syringes empty and need to be refilled. Sample is introduced through the valve injection loop (usually 10 or 20µl capacity) switching the sample plug into the mobile phase flow. Tuning and acquisition are carried out as the sample plug enters the source. (At a flow rate of 10 µl/min a 20µl injection lasts 2 minutes.) Reciprocating Pump and Injection Valve A flow of mobile phase solvent passes through an injection valve to the electrospray source. Sample injection and analysis procedure is the same as for the syringe pump. The pump reservoirs are simply topped up for continuous operation. The most suitable reciprocating pumps for this purpose are those which are specified to deliver a flow between 1 µl/min and 1 ml/min. A constant flow at such rates is more important than the actual flow rate. The injection valve on reciprocating pumps may be replaced by an autosampler for unattended, overnight operation. Infusion Pump The pump syringe is filled with sample in solution. The infusion pump then delivers the contents of the syringe to the source at a constant flow rate. This arrangement allows optimization and analysis while the sample flows to the source at typically 5-30 µl/min. Further samples require the syringe to be removed, washed, refilled with the next sample, and replumbed. A 50:50 mixture of acetonitrile and water is a suitable mobile phase for the syringe pump system and the reciprocating pump systems. This is appropriate for positive and negative ion operation. Introduction 41 3 Positive ion operation may be enhanced by 0.1 to 1% formic acid in the sample solution. Negative ion operation may be enhanced by 0.1 to 1% ammonia in the sample solution. Acid should not be added in this mode. These additives should not be used in the mobile phase for flow injection analysis (FIA) studies, to allow easy change over between positive and negative ion analysis. Degassed solvents are recommended for the syringe and reciprocating pumps. Degassing can be achieved by sonification or helium sparging. The solvents should be filtered, and stored under cover at all times. It is wise periodically to check the flow rate from the solvent delivery system. This can be carried out by filling a syringe barrel or a graduated glass capillary with the liquid emerging from the probe tip and timing a known volume, say 10µl. Once the rate has been measured and set, a note should be made of the back pressure readout on the pump as fluctuation of this reading can indicate problems with the solvent flow. 3.1.1 Post-column Splitting Although the electrospray source can accommodate flow rates up to 1 ml/min, it is recommended that the flow is split post-column to approximately 200 µl/min. Also, even at lower flow rates, a split may be required to save valuable samples. The post-column split consists of a zero dead-volume tee piece connected as shown in Figure 3-2. The split ratio is adjusted by increasing or decreasing the back pressure created in the waste line, by changing either the length or the diameter of the waste tube. A UV cell may also be incorporated in the waste line, avoiding the requirement for in-line, low volume “Z cells”. As the back pressure is varied, the flow rate at the probe tip should be checked as described above. These principles apply to splitting for both megaflow and normal flow electrospray. 42 Electrospray 3 Figure 3-2 Post Column Split Figure 3-3 Comparison of Normal and Megaflow Electrospray To Waste or UV Cell LC Column Probe PTFE Sleeve PTFE Sleeve Fused Silica Tube 1/16″ o.d. 0.007″ i.d. Peek Tube Injector Normal Flow Electrospray Megaflow Electrospray Operation 43 3 3.1.2 Megaflow Megaflow electrospray (Figure 3-3) enables flow rates from 200 µl/min to 1 ml/min to be accommodated. This allows microbore (2.1mm) or 4.6mm diameter columns to be interfaced without splitting. Changing Between Flow Modes When changing between megaflow and standard electrospray operation, it is essential that the correct tubing is used to connect the probe to the sample injector. For megaflow operation 1/16″ o.d., 0.007″ i.d. peek tubing, easily identified by its yellow stripe, is used. This replaces the standard fused silica tube, together with the PTFE sleeves. 3.2 Operation Figure 3-4 ESI Source Caution: Operating the source without the source enclosure will result in solvent vapor escape and the exposure of hot surfaces and high voltages. Blanking Plug Corona Discharge Pin Mounting Contact Exhaust Liner High Voltage Socket Cleanable Baffle 44 Electrospray 3 Ensure that the source is assembled as described in Maintenance and Fault Finding, and that the instrument is pumped down and prepared for electrospray operation as described in Routine Procedures. Ensure that a supply of nitrogen has been connected to the gas inlet at the rear of the instrument and that the head pressure is between 6 and 7 bar (90-100 psi). Ensure that the exhaust liner and the cleanable baffle are fitted to the source. This is important for optimum electrospray intensity and stability when operating at low flow rates. Checking the ESI Probe 1. Connect the electrospray probe to a pulse free pump. 2. Solvent should be degassed to prevent beam instabilities caused by bubbles. 3. Connect the PTFE tubing of the electrospray probe to Nebuliser Gas on the front panel. Secure with the nut provided. 4. With the probe removed from the source turn on the liquid flow at 10 µl/min and check that liquid flow is observed at the tip of the capillary. 5. To avoid unwanted capillary action effects, do not allow liquid to flow to the probe for long periods without the nitrogen switched on. 6. Turn on Nitrogen by selecting API Gas, and check that a nebuliser flow of less than 100 litres/hour is registered. 7. To monitor the flow rate, select Window then Gas Flow on the tune page and observe the readback window. 8. Check that there is gas flow at the probe tip and ensure that there is no significant leakage of nitrogen elsewhere. 9. Adjust the probe tip to ensure complete nebulization of the liquid. Operation 45 3 There should be approximately 0.5 mm of sample capillary protruding from the nebulizing capillary (Figure 3-5). Figure 3-5 Electrospray Tip The tip of the electrospray probe can influence the intensity and stability of the ion beam. A damaged or incorrectly adjusted probe tip will lead to poor electrospray performance. 10. Using a magnifying glass ensure that both inner and outer stainless steel capillaries are straight and circular in cross-section. 11. Ensure that the inner stainless steel capillary is coaxial to the outer capillary. If the two capillaries are not coaxial, it is possible to bend the outer capillary slightly using thumbnail pressure. 12. Insert the probe into the source and tighten the two thumb screws. 13. Plug the probe high voltage cable into Capillary / Corona on the front panel. Obtaining an Ion Beam 1. If necessary, change the ionization mode using the Ion Mode command. 2. Using the needle valve on the front panel, set the desolvation gas flow rate to 300 litres/hour. 3. Turn on the liquid flow at 10 µl/min and set Desolvation Temp to 100°C. 0.6mm Sample Capillary Nebulising Capillary Probe Tip Assembly 46 Electrospray 3 Tuning and Optimization The following parameters, after initial tuning, should be optimized using a sample representative of the analyte to be studied. It will usually be found, with the exception of the sample cone voltage, that settings will vary little from one analyte to another. Probe Position Figure 3-6 Optimum Probe Position The position of the probe (Figure 3-6) is adjusted using the probe adjustment collar (in and out) and the adjustment knob (sideways) located to the left of the probe (Figure 3-7). The two screws can be adjusted singly or simultaneously to optimize the beam. The position for optimum sensitivity and stability for low flow rate work (10 µl/min) is shown. Figure 3-7 Probe Adjustment 8mm Cone Gas 4mm Nozzle Probe Tip In / Out Probe Adjustment Sideways Probe Adjustment Operation 47 3 Small improvements may be gained by varying the position using the sample and solvent system under investigation. The following information should be considered when setting the probe position: • 10 mm of movement is provided in each direction, with 1.25mm of travel per revolution of the probe positioning controls. • At higher liquid flow rates the probe tip should be positioned further away from the sample cone to achieve optimum stability and sensitivity. The position is less critical than at lower flow rates. Nebuliser Gas Optimum nebulization for electrospray performance is achieved with a nitrogen flow between 70 and 90 litres per hour. This can be achieved by fully opening the Nebuliser flow control valve, which is situated on the instrument’s front panel. Desolvation Gas The desolvation gas, also nitrogen, is heated and delivered as a coaxial sheath to the nebulized liquid spray by the desolvation nozzle. Note: The position of the desolvation nozzle heater is fixed relative to the probe tip and requires no adjustment. The Desolvation Gas flow rate is adjusted by the control value situated on the instrument’s front panel. The optimum Desolvation Temp and flow rate is dependent on mobile phase composition and flow rate. A guide to suitable settings is given below. The Desolvation Gas flow rate indicated on the MassLynx tune page represents total drying flow, that is desolvation gas + cone gas (nanoflow only) + purge gas (if enabled). Solvent Flow Rate µl/min Desolvation Temp OC Desolvation Gas Flow Rate Litres/hour <10 100 – 120 200 – 250 10 – 20 120 – 250 200 – 400 20 – 50 250 – 350 200 – 400 >50 350 – 400 500 – 750 48 Electrospray 3 Higher desolvation temperatures give increased sensitivity. However increasing the temperature above the range suggested reduces beam stability. Increasing the gas flow rate higher than the quoted values leads to unnecessarily high nitrogen consumption. Cone Gas The cone gas reduces the intensity of solvent cluster ions and solvent adduct ions. The cone gas flow rate should be optimized by increasing until solvent cluster ions and / or adduct ions are reduced as much as possible without diminishing the intensity of the ion of interest, normally (M+H)+. Typical cone gas flow rates are in the range 100 to 300 litres per hour. Purge Gas The purge gas is not necessary for most ESI applications. It may be useful for megaflow operation where an analyte is susceptible to acetonitrile adducting. Purge gas is enabled simply by removing the blanking plug from the outlet situated within the source enclosure. Purge gas flow rate is a constant fraction (30%) of the total desolvation gas flow. Source temperature 100°C is typical for 50:50 CH3CN:H2O at solvent flow rates up to 50 µl/min. Higher source temperatures, up to 150°C, are necessary for solvents at higher flow rates and higher water content. Capillary Voltage Capillary usually optimizes at 3.0kV, although some samples may tune at values above or below this, within the range 2.5 – 4.0kV for positive electrospray. For negative ion operation a lower voltage is necessary, typically between 2.0 – 3.5kV. At high flow rates this parameter may optimize at a value as low as 1kV. Attention: Do not operate the desolvation heater for long periods of time without a gas flow. To do so could damage the source. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Temp higher than 150°C Operation 49 3 Sample Cone Voltage A Cone setting between 25V and 70V will produce ions for most samples, although solvent ions prefer the lower end and proteins the higher end of this range. Whenever sample quantity and time permit, Cone should be optimized for maximum sensitivity, within the range 15V to 150V. Increasing Cone will increase ion fragmentation within the source. Extraction Cone Voltage Extractor optimizes at 0 – 5V. Higher values may induce ion fragmentation of low molecular weight samples. 3.2.3 Megaflow Hints With this high flow rate technique the setup procedure involves making the following adjustments: • Increase Desolvation Gas flow to 500 litres/hour. • Increase Desolvation Temp to 400°C. • Increase Source Block Temp to 150°C. • Move the probe further away from the sample cone. Note: When changing from electrospray to megaflow operation it is not necessary to adjust any source voltages. Cluster ions are rarely observed with Z-spray. However solvent droplets may form within the source enclosure if the source and desolvation temperatures are too low. Refer to the previous section on operating parameters for typical desolvation gas flow rates. Purge gas can be used during megaflow operation to stop the source enclosure from overheating. This is also beneficial when the analyte is susceptible to acetonitrile adducting. Purge gas is enabled by removing the blanking plug from the outlet situated within the source enclosure. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. 50 Electrospray 3 If the sample is contained within a ‘dirty matrix’ the probe may be moved away from the sample cone to extend time between source cleaning operations. This may incur a small loss in sensitivity. The source enclosure will run cooler if purge gas is used. 3.2.4 Removing the Probe To remove the probe from the source proceed as follows: 1. On the tune page deselect Operate to put the instrument into standby mode. 2. Switch off the liquid flow and disconnect from the probe. 3. Deselect API Gas and turn off Nitrogen. 4. Disconnect the probe cable from the instrument. 5. Disconnect the nebulizing gas supply from the instrument. 3.3 Sample Analysis and Calibration 3.3.5 General Information Care should be taken to ensure that samples are fully dissolved in a suitable solvent. Any particulates must be filtered to avoid blockage of the transfer line or the probe’s capillary. A centrifuge can often be used to separate solid particles from the sample liquid. Caution: It is normal for the source enclosure, the glass tube and parts of the probe mounting flange, to get hot during prolonged megaflow operation. Care should be taken when handling source components during and immediately after operation. Attention: For health and safety reasons always ensure the exhaust line is vented outside the building or to a fume hood. Attention: Ensure that a plastic bottle is connected in the exhaust line to collect any condensed solvents. Sample Analysis and Calibration 51 3 There is usually no benefit in using concentrations greater than 20 pmol/µl for biopolymers or 10 ng/µl for low molecular weight compounds. Higher concentrations will not usually improve analytical performance. Conversely, for biopolymers, lower concentrations often yield better electrospray results. Higher levels require more frequent source cleaning and risk blocking the transfer capillary. Optimization for low molecular weight compounds may usually be achieved using a concentration of 1ng/µl. Samples with phosphate buffers and high levels of salts should be avoided. Alternatively, at the expense of a small drop in sensitivity, the probe can be pulled away from the sample cone to minimize the deposit of involatile material on the cone. To gain experience in sample analysis, it is advisable to start with the qualitative analysis of known standards. A good example of a high molecular weight sample is horse heart myoglobin (molecular weight 16951.48) which produces a series of multiply charged ions that can be used to calibrate the m scale from 800-1600 in either positive ion or negative ion mode. Polyethylene glycol mixtures, for example 300 / 600 / 1000, are low molecular weight samples suitable for calibrating the m scale from approximately 100 to 1200 in positive ion mode. A mixture of sugars covers the same range in negative ion mode. Alternatively, sodium iodide or caesium iodide can be used for calibration. 52 Electrospray 3 Typical ES Positive Ion Samples • Peptides and proteins. • Small polar compounds. • Drugs and their metabolites. • Environmental contaminants (e.g. pesticides, pollutants). • Dye compounds. • Some organometallics. • Small saccharides. Typical ES Negative Ion Samples • Some proteins. • Some drug metabolites (e.g. glucuronide conjugates). • Oligonucleotides. • Some saccharides and polysaccharides. 3.4 Chromatographic Interfacing Electrospray ionization can be routinely interfaced to reversed phase and normal phase chromatographic separations. Depending on the LC pumping system, chromatography column and setup, there are some basic options: • Microbore and capillary chromatography separations employing 1mm diameter (and smaller) columns can be interfaced directly to the electrospray probe. Typical flow rates for such columns may be in the region of 3-50 µl/min. It is suggested that a syringe pump is used to deliver these constant low flow rates through a capillary column. Alternatively, accurate pre-column splitting of higher flow rates from reciprocating pumps can be investigated. In all cases, efficient solvent mixing is necessary for gradient elution separations. This is of paramount importance with regard to low flow rates encountered with capillary columns. HPLC pump manufacturers’ recommendations should be heeded. • 2.1mm diameter reversed phase columns are gaining popularity for many separations previously addressed by 4.6mm columns. Typically flow rates of 200 µl/min are Chromatographic Interfacing 53 3 used, allowing direct coupling to the electrospray source. The increased sample flow rate requires increased source temperature and drying gas flow rate. A UV detector may be placed in-line to the probe, provided that the volume of the detector does not significantly reduce the chromatographic resolution. Whenever a UV detector is used, the analog output may be input to MassLynx NT for chromatographic processing. • The interfacing of 4.6mm columns to the electrospray source can be achieved either by flow splitting or by direct coupling. In both cases an elevated source temperature and drying gas flow rate are required. In general, the best results are obtained by splitting after the column using a zero dead volume tee piece so that 200-300 µl/min is transferred to the source. Conventional reverse phase and normal phase solvent systems are appropriate for LC-electrospray. Involatile buffers may be used but prolonged periods of operation are not recommended. When using involatile buffers the probe should be moved as far away from the sample cone as possible. This may reduce sensitivity slightly, but will reduce the rate at which involatile material will be deposited on the sample cone. Trifluoroacetic acid (TFA) and triethylamine (TEA) may be used up to a level of 0.05%. If solvents of high aqueous content are to be used then tuning conditions should be appropriate for the solvent composition entering the source. Higher source temperatures (150°C) are also recommended for high aqueous content solvents. Tetrahydrofuran (THF) should not be used with peek tubing. 3.4.1 LC-MS Sensitivity Enhancement The sensitivity of a LC-MS analysis can be increased or optimized in a number of ways, by alterations to both the LC operation and the MS operation. In the LC area some examples include the use of high resolution columns and columns with fully end capped pickings. For target compound analysis, techniques such as trace enrichment, coupled column chromatography, or phase system switching can have enormous benefits. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. 54 Electrospray Careful choice of the solvent, and solvent additives or modifiers, may also prove important. 55 4 Chapter 4 Nanoflow Electrospray Figure 4-1 The Nanoflow Interface The optional nanoflow interface allows electrospray ionization to be performed in the flow rate range 5 to 1000 nl/min. There are two options for the spraying capillary, which can be alternately fitted to the interface: • Borosilicate metal coated glass capillary. Metal coated glass capillaries allow the lowest flow rates to be obtained although they are used for one sample only and must then be discarded. • Nano-LC. Regulator and Injector (Nano-LC option) Protective Cover Handle Stop Glass Capillary Option Nano-LC Option Stage Three-axis Manipulator 56 Nanoflow Electrospray 4 This option is suitable for flow injection analyses or for coupling to nano-HPLC, and uses a pump to regulate the flow rate down to 100 nl/min. If a syringe pump is to be used, a gas-tight syringe is necessary to obtain correct flow rates without leakage. A volume of 25µl is recommended. Figure 4-2 Nanoflow Electrospray Scheme For a given sample concentration, the ion currents observed in nanoflow are comparable to those seen in normal flow rate electrospray. Great sensitivity gains are therefore observed when similar scan parameters are used, due to the great reductions in sample consumption. The nanoflow end flange consists of a three-axis manipulator, a stage, a protective cover and a stop / handle arrangement for rotation of the manipulator and stage. The manipulator and stage are rotated by 90 degrees to change option or, in the glass capillary option, to load a new nanovial. Attention: Failure to use the stop and handle to rotate the stage can result in permanent damage to the three-axis manipulator. Exhaust Exhaust Liner Turbomolecular Pumps Rotary Pump Cone Gas Purge Gas Analyser Sample Cone Extraction Cone Isolation Valve Source Enclosure RF Lens Cleanable Baffle Sample Capillary Installing the Interface 57 4 4.1 Installing the Interface To change from the normal electrospray interface and install the nanoflow interface: 1. If fitted, remove the probe. 2. Remove the moulded cover from around the source. 3. Undo the three thumb screws and withdraw the probe adjustment flange assembly and glass tube. 4. Place the glass tube, end on, on a flat surface and place the probe support flange assembly on top of the glass tube. 5. Remove the PTFE encapsulated source O ring. Figure 4-3 Electrospray Source Being Removed 6. Unscrew the three probe flange mounting pillars, using the holes to obtain the necessary leverage. Caution: When the source enclosure has been removed the ion block heater is exposed. Ensure that the source block heater has been switched off and has cooled before proceeding. Observe the Source Block Temp readback on the Tune Page Source Thumb Nuts Probe Thum b Nuts Probe Adjustment Flange Source Enclosure Probe Flange Mounting Pillar 58 Nanoflow Electrospray 4 7. If the cone gas nozzle is not in place, close the sample cone isolation valve. Remove the two screws that secure the sample cone and fit the cone gas nozzle. 8. Replace the two screws. 9. Connect the cone gas outlet to the cone gas nozzle using the PTFE tubing provided (Figure 4-4). Open the sample cone isolation valve. Figure 4-4 Nanoflow Source Without Cover The cone gas flow rate is set at 30% of the total desolvation gas flow. 10. Ensure that the purge gas is plugged (disabled). 11. Ensure that the cleanable baffle, the exhaust liner and the corona discharge pin blanking plug are fitted. 12. Fit a viton O ring and the three shorter nanoflow pillars. 13. Install the perspex cover and the nanoflow end flange, securing this with socket head screws. Cone Gas Nozzle PTFE Tubing PTFE Encapsulated O Ring Purge Gas Plug Installing the Interface 59 4 Figure 4-5 Nanoflow Source with Cover and End Flange Do not attempt to refit the moulded cover. 14. If not already in place, attach the microscope or camera brackets using the screw hole and dowels at the top of the bracket. 15. Insert the flexible light guide into the grommet at the base of the perspex cover. 16. Set the light source to its brightest. 17. Block the Desolvation Gas outlet on the instrument’s front panel. 18. Close the nebuliser needle valve. The cone gas is split from the desolvation gas internally. 19. Attach the two cables to the sockets marked Capillary / Corona and Probes on the front panel of the instrument. 20. Set Source Block Temp to approximately 80°C. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. Viton O Ring Socket Head Screws Nanoflow End Flange Perspex Cover 60 Nanoflow Electrospray 4 4.1.1 Operation of the Camera System Figure 4-6 Nanoflow Camera and Microscope System Magnification is controlled by the zoom lens. A fine focus can be achieved by rotating the objective lens. Using the Microscope Focusing is adjusted by rotating the top of the microscope. Microscope Camera Zoom Lens Objective Lens Grommet Installing the Interface 61 4 4.1.2 Glass Capillary Option Installation 1. With the stage rotated outwards, unscrew the union from the end of the assembly. 2. Carefully remove the capillary from its case by lifting vertically while pressing down on the foam with two fingers. 3. Over the blunt end of the capillary, pass the knurled nut, approximately 5mm of conductive elastomer and finally the union. 4. Tighten the nut (finger tight is sufficient) so that 5mm of glass capillary is protruding from the end of it. This distance is measured from the end of the nut to the shoulder of the glass capillary. 5. Load sample into the capillary using either a fused silica syringe needle or a GELoader tip. 6. Screw the holder back into the assembly – finger tight is sufficient. 7. Ensure that Capillary is set to 0V on the tune page. 8. Rotate the stage back into the interface using the stop and handle. When using a GELoader tip, break the nanovial in half, by scoring with a fused silica cutter. This enables the GELoader to reach the tip of the nanovial Nanovial Tip Position The position of the nanovial is adjusted as shown (Figure 4-7). The tip is in line with the centre of the sample cone, at a distance between two and three times the diameter of the cone orifice, as observed through the microscope. Caution: Do not touch the sharp end of the capillary. As well as the risk of injury by a sliver of glass, the capillary may contain toxic sample.s Caution: The capillaries are extremely fragile and must be handled with great care. Always handle using the square end of the capillary. The needle may become inoperable if the sharp end is touched. 62 Nanoflow Electrospray 4 Figure 4-7 Nanovial Tip Position Operation Manoeuvre the stage so that the microscope or camera can view the capillary tip. Using the nanoflow regulator, apply pressure to the back of the tip until a drop of liquid is seen. On the tune page, select APIGas to turn on Nitrogen. Select Operate. Set Capillary between 600 and 1.0kV. Adjust Desolvation Gas flow to 100 litres/hour using the knob on the front panel of the instrument. An ion beam should now be visible on the tune page. Tune the source voltages, adjust the gas flow and adjust the three-axis manipulator for maximum ion current. The ion current may change dramatically with very slight changes of position but the high resolution of the threads in the manipulator allows very fine tuning. Restarting the Spray Should the spray stop, it is possible to restart it by adjusting the three-axis manipulator so that, viewed under magnification, the capillary tip touches the sample cone and a small piece of the glass hair shears off. Set the capillary to zero when doing this. Nano-LC Option 63 4 It may also be necessary to apply some back pressure to the holder to force a drop of liquid from the capillary. Up to 1.4 bar (20 psi) can be applied and, with this pressure, a drop should be visible unless the capillary is blocked. 4.2 Nano-LC Option 4.2.1 Installation With the sprayer assembly removed from the stage and with refrence to Figure 4-8: 1. Cut approximately 25mm of the red stripe peek tubing and, using the plug cap and a Valco nut, set a ferrule to the correct position on the tubing. At this stage the ferrule is required only to grip the tubing lightly, and should not be too tight. 2. Cut the peek such that 10mm of the peek protrudes from the back of the ferrule. 3. Thread approximately 70mm of the 90 micron o.d. fused silica through the new fitting. 4. Ensure that the fused silica is flush with the peek sleeve. 5. Again using the plug cap, tighten the nut further to ensure that the fused silica is gripped. Some force may be required to do this. 6. Remove the sleeved fused silica from the plug cap and remove the Valco nut. 7. Place an O ring onto the peek tube, using tweezers if necessary. The O ring is required to seal the region between the ferrule and the end of the thread on the nano-LC chamber. 8. Thread the sleeved fused silica through the nano-LC chamber. 9. Rotate the microvolume union in the body such that the ferrule seat is aligned correctly. 10. Insert the chamber into the nano-LC body and tighten using a pair of spanners. The capillary can now be checked for flow by connecting the output from a Harvard syringe pump to the other side of the union and setting the flow to 1 µL/min, using a micropipette to measure the flow. It is recommended that a syringe with a volume of no more than 50 millilitres is used. 64 Nanoflow Electrospray 4 Figure 4-8 Nano-LC Assembly 11. Thread the fused silica through the nebulizing tip and screw in the nano-LC chamber such that it is screwed in approximately half way. 12. Cut the fused silica using a tile cutter and adjust the nebulizing tip further, such that 1mm of fused silica protrudes from the tip. 13. Attach the nebulizing gas tubing to the sprayer using an O ring and the special screw. 14. Attach the sprayer assembly to the stage. 1mm From Injector (or Column Attached Directly) Make-up Flow Only (3-way Insert Required) Nebuliser Gas Nano-LC Body Chamber Nebulising Tip Red Stripe Peek Tubing O Ring 90µm Fused Silica Valco Ferrule Microvolume Insert Nano-LC Option 65 4 It may be necessary to alter the position of the thumbscrew underneath the baseplate to attach the sprayer correctly. 15. Swing the stage into the interface using the stop and handle. 4.2.2 Operation For tuning purposes it may be useful to infuse a known sample in 95% water using a Harvard syringe pump. 1. Set the liquid flow to about 200 nl/min. 2. Switch on Gas at the MassLynx tune page. 3. Set the pressure of the gas on the regulator to approximately 0.5 bar (7 psi). 4. Ensure there are no leaks of gas at the sprayer, particularly where the PTFE tubing is connected to it. Note: By viewing under magnification, the spray emanating from the capillary may be examined and tuned by altering the nebulizing tip such that a fine spray is observed. Altering the gas slightly may also help in this tuning process. 5. Swing the stage back out of the source and place the cover over the sprayer ensuring that the tubing coming from the sprayer is threaded correctly through it. 6. Lock the cover in place with two screws. 7. Swing the stage back into the source and alter the translation stage (in / out direction) such that the capillary is approximately 5mm from the cone. 8. Select Operate and set Capillary to approximately 2.5kV. An ion beam should now be present. 9. Optimize the ion beam by altering the position of the spray using the controls of the translation stage. 10. The sprayer can now be connected to the HPLC system. The injection valve is plumbed as follows: • P from the pump. • C to the column (or to the union). • S is the sample port, attach a VISF sleeve here. • W is a waste port. Note: A short tail of fused silica, attached to the entrance port of the union, and the use of low pressure PTFE connectors will remove the need to move the stage. This will prevent 66 Nanoflow Electrospray 4 accidental alteration of the sprayer’s position when changing between tuning and HPLC operation. 4.3 Changing Options To change between the glass capillary and the nano-LC options: Rotate the stage outwards.: Remove the protective cover and release the captive screw located underneath the stage. Lift off the holder and replace it with the alternative holder, securing it with the captive screw. Replace the protective cover, ensuring that either the PTFE back pressure tubing (glass capillary option) or the fused silica transfer line is fed through the slot in the back of the protective cover along with the HV cabling. Attention: Failure to use the stop and handle to rotate the stage can result in permanent damage to the three-axis manipulator. 67 5 Chapter 5 APcI Atmospheric Pressure Chemical Ionization (APcI) is an easy to use LC-MS interface that produces singly-charged protonated or deprotonated molecules for a broad range of involatile analytes. Figure 5-1 Schematic Representation of APcI The ability to operate with 100% organic or 100% aqueous mobile phases at flow rates up to 2 ml/min makes APcI an ideal technique for standard analytical column (4.6 mm i.d.) normal phase and reverse phase LC-MS. The APcI interface consists of the standard Z-spray source fitted with a corona discharge pin and a heated nebuliser probe. Mobile phase from the LC column enters the probe where it is pneumatically converted into an aerosol and is rapidly heated and converted to a vapor / gas at the probe tip. Hot gas from the probe passes between the sample cone and the corona discharge pin, which is typically maintained at 2.5kV. Mobile phase molecules rapidly react with ions generated by the corona discharge to produce stable reagents ions. 68 APcI 5 Analyte molecules introduced into the mobile phase react with the reagent ions at atmospheric pressure and typically become protonated (in positive ion mode) or deprotonated (in the negative ion mode). The sample and reagent ions pass through the sample cone into the ion block prior to being extracted via the extraction cone into the RF lens. Changeover between electrospray and APcI operation is simply accomplished by changing the probe and installing the corona discharge pin within the source enclosure. For APcI operation, the desolvation gas is not heated in the desolvation nozzle. However, it is important that desolvation gas is used throughout. The background spectrum for 50:50 acetonitrile:water is dependent upon the settings of Cone and Extractor. The main reagent ions for typical sample cone and extraction cone voltages of 40V and 10V respectively are 42, 56, 83 and 101. The transmission of these ions will be dependent on the setting of RF Lens. A lower RF Lens voltage is required for optimum transmission at lower m. Acetonitrile adducting may be minimized by optimization of the probe position, as described in the chapter entitled Electrospray. 5.1 Preparation Ensure that the source is assembled as described in Maintenance and Fault Finding, and that the instrument is pumped down and prepared for APcI operation as described in Routine Procedures. APcI may be operated with or without the cleanable baffle fitted. Ensure that a supply of nitrogen has been connected to the gas inlet at the rear of the instrument and that the head pressure is between 6 and 7 bar (90-100 psi). 5.1.1 Checking the Probe 1. Ensure that the probe heater is off. 2. Unplug the probe from the instrument’s front panel and remove the probe from the source. 3. Connect the PTFE tube to the Nebuliser Gas outlet on the front panel. 4. Remove the probe tip assembly by carefully loosening the two grub screws. Obtaining an Ion Beam 69 5 5. Disconnect the heater from the probe body by pulling parallel to the axis of the probe. 6. Ensure that 0.5 to 1 mm of fused silica is protruding from the stainless steel nebuliser tube. 7. Connect the LC pump to the probe with a flow of 50:50 acetonitrile:water at 1 ml/min. 8. Check that the liquid jet flows freely from the end of the capillary and that the LC pump back pressure reads 250 to 400 psi. 9. Check that the nitrogen supply pressure is 6 to 7 bar (90 to 100 psi). 10. Select API Gas and turn on Nitrogen. 11. Check that the liquid jet converts to a fine uniform aerosol. 12. Switch off the liquid flow. 13. Deselect API Gas and turn off Nitrogen. 14. Reconnect the probe tip assembly. 15. Insert the APcI probe into the source and secure it by tightening the two thumb screws. 16. Connect the probe cable to Probes on the instrument’s front panel. 5.2 Obtaining an Ion Beam 1. Ensure that the corona discharge pin is fitted as described in Section 2.2.2 on page 26 and that the pin is connected using the APcI HV cable. 2. Ensure that the APcI probe is fitted as described above, that the desolvation gas tube is connected to the front panel, and that the cone gas and purge gas outlets are plugged. 3. If necessary, change the ionization mode using the Ion Mode command. 4. Set Source Block Temp to 150°C. 5. Set APcI Probe Temp to 20°C with no liquid flow and Nitrogen off. 6. Initially set Corona to 2.5kV and Cone to 30V. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C 70 APcI 5 When Source Block Temp reaches 150°C: 1. Select API Gas to switch on the nitrogen gas. 2. Using the valves on the front of the instrument, adjust Desolvation Gas to 150 litres/hour and set Nebuliser Gas to its maximum setting. 3. Set one of the peak display boxes to show masses down to at least 100 Da. 4. Select Operate. 5. Set APcI Probe Temp to 350°C. When APcI Probe Temp reaches 350°C: 1. Start the LC pump at a flow of 1 ml/min. 2. Optimize Corona so that the peaks reach maximum intensity. 3. Optimize the probe position for intensity and stability. The two screws can be adjusted singly or simultaneously to optimize the beam. Figure 5-2 Illustration of Probe Adjustment The position of the probe will affect sensitivity. However, if the sample is contained in a ‘biological matrix’ or is contained in an involatile solvent the probe should be moved away from the sample cone and towards the corona discharge pin Hints for Sample Analysis 71 5 . 5.3 Hints for Sample Analysis Tuning • Start by tuning on the solvent ions. • It is generally found that the most significant analyte tuning parameter to adjust following tuning on the solvent ions is Cone. • Fine tuning on the analyte of interest can be performed either by large loop injections (100µl) or by constant infusion in the mobile phase typically at analyte concentrations of a few ng/µl. • 10µl loop injections can be monitored using real time chromatogram updates. Mobile Phase • The choice of mobile phase is an important compound specific factor in APcI. For example, steroids prefer methanol:water mixtures as opposed to acetonitrile:water. • Analyte sensitivity is also dependent on mobile phase composition, which can be varied from 100% aqueous to 100% organic for any particular mixture. Probe Temperature This can be a critical factor for some analytes. Caution: It is normal for the source enclosure, the glass tube and parts of the probe adjustment flange to reach temperatures of up to 60°C during prolonged APcI operation. Care should be exercised when handling source components immediately after operation. Caution: Switch off the liquid flow and allow the probe to cool (<100°C) before removing it from the source. Attention: Failure to employ a desolvation gas flow during APcI operation may lead to heat damage to the source. 72 APcI 5 • Involatile samples (for example steroids) generally require high probe temperatures (>400°C). • Volatile samples (for example pesticides) can be analyzed with low probe temperatures (<400°C). • In some cases, too high a probe temperature can lead to thermal degradation of labile samples. Desolvation Gas Although a Desolvation Gas flow of approximately 150 litres/hour is typical for most samples, this flow rate should be tuned for maximum sensitivity while ensuring that the flow rate is not decreased below 100 litres/hour. 5.4 Removing the Probe Figure 5-3 APcI Probe showing twin Thumb Nuts used for Removal After a session of APcI operation: Turn off the LC flow. Set APcI Probe Temp to 20°C. Deselect Operate to put the instrument in standby mode. When the probe temperature falls below 100°C: Removing the Probe 73 5 Deselect API Gas and turn off Nitrogen. Undo the two thumb nuts and remove the probe from the source (Figure 5-3). If the instrument is not to be used for a long period of time the source temperature should be reduced to 60°C. Caution: Take care when removing the APcI probe. There is a risk of burns to the operator. Attention: Removal of the APcI probe when hot will shorten the life of the probe heater. 74 APcI Tuning 75 6 Chapter 6 Tuning Before sample data are acquired, the instrument should be tuned and, for highest mass accuracy, calibrated using a suitable reference compound (see Chapter 7). Consult the relevant sections of this manual for information concerning source tuning procedures in the chosen mode of operation. See: • Chapter 3, Electrospray • Chapter 4, Nanoflow Electrospray • Chapter 5, APcI For information on optimizing peak shape, intensity and resolution and adjusting the tuning parameters see the following sections: • Section 6.2.4, Source Tuning Page • Section 6.2.5, Quadrupole Tuning Page (Analyzer) • Section 6.2.6, Time Of Flight Page • Section 6.3, Obtaining an Ion Beam Note: Care should be taken to optimize the value of the collision energy. 6.1 Tuning The preceding sections have outlined the software controls and connections to establish the physical conditions required as a prerequisite to mass spectrometer operation. Within the source and analyzer enclosures, electric fields controlled via MassLynx are applied to the components to manage the ion beam generated, according to the sample to be analyzed, the ionization mode and the type of information required. The ion optical system elements are indicated in Figure 6-1 on page 76. Considering the variable nature of the beam with different samples, the instrument should be tuned for signal strength and calibrated for accurate m using suitable reference compounds, prior to the acquisition of sample data. 76 Tuning 6 Figure 6-1 The Ion Optical System of the Q-Tof micro Tuning parameters have been grouped in MassLynx into 3 pages as inSection 6.3 on page 89. Full details of source tuning procedures for electrospray, APcI and nanoflow electrospray are given in the relevant chapter of this manual. Tune Page 77 6 6.2 Tune Page Figure 6-2 The QTof micro Tune Page The Tune Page Consists of a peak display window and 3 pages of parameters viewable by selecting the relevant tab. These are: • The Source Page (see Section 6.2.4) • The Quadrupole Page (see Section 6.2.5) • The time of Flight Page (see Section 6.2.6) 6.2.1 Tune Page Basics To Display the Tune Page: Select MS Tune from the Masslynx Shortcut bar (Figure 6-2). 78 Tuning 6 Printing Tune Information To print a report, containing a copy of the tune peak information displayed on the screen along with a record of each parameter setting: Press , or select Print from the Tune Page File menu. This report is not configurable by the user. Experimental Record Tuning parameters are stored with every data file as part of the experimental record. The tuning parameters for a particular data file can be viewed or printed from the data browser, see the MassLynx User Guide, Selecting and Viewing Data, for more information. 6.2.2 Saving and Restoring Parameter Settings Whole sets of instrument tuning parameters can be saved to disk as a named file and then recalled at a future date. A tune parameter file contains the latest settings for the source controls for all supported ionization modes not just the ionization mode currently selected. Tune parameter files also contain settings for the analyzer, inlet set points and peak display. To save the current tune parameters with the existing file name: 1. Press , or choose Save from the tune page File menu. 2. Press Save. To save the current tune parameters with a new file name: 1. Select Save As from the tune page File menu. 2. Enter a new file name or select an existing file from the list displayed. 3. Press Save. If the selected file already exists on disk a warning is displayed. Press Yes to overwrite the existing information or No to enter a different file name. To restore a saved set of parameters: 1. Press , or choose Open from the tune page File menu. 2. Select the required tuning parameter file, either by typing its name or by selecting from the list displayed. 3. Press Open. Tune Page 79 6 6.2.3 Changing the Peak Display To change the display using the mouse: Figure 6-3 The Customize Display Menu Click in the peak display area with the right mouse button to display the pop up menu (Figure 6-3). The display area for each peak can be individually changed, e.g. the peak color for peak 1 can be red and for peak 2 green etc. Customize Plot Appearance To change the color of the background and traces and to change the number of traces displayed: Figure 6-4 The Customise Plot Appearance Dialog 80 Tuning 6 Select Customize, Plot Appearance. The Customize Plot Appearance dialog is displayed (Figure 6-4). To change the colours on the display: Press Newest Trace, Background or Trace Fill and select a new color from the dialog displayed. To change the number of traces: Use to change the number, or enter a new value in the Visible Traces box, within the range 2 to 20. If more than one trace is displayed then the older traces can be displayed in a different shade to the new ones: Drag the Color Interpolation slider toward the full position. The color of the old traces is shown in the Trace color sample (new->old) field. Trace From the pop-up menu do one of the following: • Select the Trace, Outline option to display the peak outline only. • Select the Trace, Fill option to fill the trace with the trace fill color. • Select the Trace, Min/Max option to show the minimum and maximum data points only. The option selected has a tick next to it. Intensity Select either Intensity, Relative Intensity or Intensity, Absolute Intensity as required. Select Intensity, Normalize Data to display normalized data. The options selected each have a tick next to them. Grid The options allow vertical and horizontal grid lines to be independently displayed or hidden. Selected Options have ticks next to them. Selecting and option a second time deselects the option. Tune Page 81 6 6.2.4 Source Tuning Page The main parameters that are changed during tuning can be found on this page. The two that have the most effect are the Capillary Voltage and Sample Cone Voltage. Figure 6-5 The Source Tuning Page The positive ion electrospray (ESP+) Source Tuning page is shown. Suggested tuning parameters are as follows: 82 Tuning 6 Capillary This sets the absolute voltage on the electrospray probe or APCI corona needle, and is typically adjusted to 3000V. The value shown in the display is for illustration only. Sample Cone This sets the voltage on the sampling cone relative to the extraction lens. It is dependent on compound and charge state. For multiply charged species this is set to 30 – 50eV, and higher for singly charged species. In general, higher cone voltages are needed for larger mass ions. Extraction Cone This sets the voltage on the extraction lens, and is normally set from 0 – 2V. Desolvation Temp This sets the temperature of the desolvation gas heater. It is usually set to 150ºC, and increased for higher solvent flow rates. Source Temp The source block temperature is usually set to 80ºC, but is increased for higher solvent flow rates. Gas Flows Gas Flow will normally be set at 20 l/h for cone and 380 – 400 l/h for Desolvation Syringe Pump Enter the desired flow rate for the Analyte. Lock Spray Choose from Reference or Analyte. Note: This box only appears if LockSpray is selected on the MassLynx Options dialog Tune Page 83 6 6.2.5 Quadrupole Tuning Page (Analyzer) Figure 6-6 The Quadrupole Tuning Page Note: The Parameters on this page do not routinely need changing. Ion Energy This sets the quadrupole offset DC with respect to the collision energy of the ions travelling between the quadrupoles. This should be set between 1 – 1.8V. 84 Tuning 6 Collision Energy This sets the collision energy of the ions when they reach the collision cell. The cell itself is grounded but the collision energy voltage is simultaneously applied to all the optical elements preceding it. i.e cone, extraction lens, source hexapole, differential pumping aperture, and quadrupole. In Q-Tof micro gas is always introduced into the cell, affording collisional cooling and consequently higher resolution. The collision energy is set to 10eV for MS mode to maximize ion transmission but produce little or no fragmentation. When in the MS/MS mode the collision energy is adjusted to give the best fragmentation pattern for the selected parent Low Mass Res and High Mass Res These set the resolving DC on the quadrupoles. The two sliders are set to give constant resolution across the mass range. When the quadrupoles have been set up, settings of 15 on both sliders should give unit resolution at 20% peak height. RF1 DC Offset Normal value is between 0 and 1V. The value shown in the display is for illustration only (item 3 in Figure 6-2). Pre/Post Filter Normal value is between 5 and 15V (items 4 and 5 in Figure 6-2). RF2 DC Offset Normal value is between 0 and 4V (item 7 in Figure 6-2). Pump Aperture Normal value is between 2 and 10V (item 6 in Figure 6-2). Plate 1 This is the voltage applied to the entrance plate of the gas cell. Normal value is 2V. The value shown in the display is for illustration only. Entrance This sets the voltage on the pusher entrance and exit, and defines the axial speed of the ions through the TOF. The theoretical value is 105 eV when the ion beam should be central to the detector. It should be optimized when looking at a TOF beam, not on the first detector. It should be possible to correctly tune the instrument using this value. The value shown in the display is for illustration only. Can This is the voltage applied to the hexapole gas cell surrounding shield. Normal value is 0. Plate 2 This is the voltage applied to the exit plate of the gas cell. Normal value is -3V. Auto MS Profiling If the box is checked then automatic MS/Hex profile will be used. If the box is not checked then Quad Mass and Gas Cell must be set manually. Tune Page 85 6 6.2.6 Time Of Flight Page Figure 6-7 The Time Of Flight Page Note: The Parameters on this page do not routinely need changing. Quad Mass This is the mass in Da at which the quad mass is set in RF only mode Gas Cell RF (V) This is the peak to peak amplitude of the applied RF voltage. 86 Tuning 6 Acceleration Lens Usually set to maximum voltage (200V) in all modes of operation.The factory setting should be noted, before attempting to improve resolution by changing this voltage. Focus This adds an equal voltage to both the top and bottom steering/focus lens halfplates. For maximum TOF resolution it is set to zero. Steering This adjusts the voltage difference between the top and bottom half plates of the steering/focus lens. It acts as a y-deflector, directing the beam into the pusher. A setting close to zero should produce an optimum beam. Better sensitivity can be achieved, however, with a voltage (positive or negative) close to zero, e.g. +1.0, -0.5 etc., and not more than ±2V. Tube Lens This is set to its optimum value in the factory and by the engineer at installation. It helps shape the ion beam on entry into the pusher and so has a large effect on resolution and peak shape. Grid 2 Offset This determines the voltage difference between the two plates of the first acceleration region of the Tof (Pusher and Grid3). It is used as a fine tuning control to optimize resolution. The optimum value for this element may change with pusher frequency. The pusher frequency is dependent on mass range when in automatic pusher mode and takes one of six discrete values. See pusher rates on Page 41. Flight Tube This sets the flight tube voltage. It is always set to 5630V. Adjusting this will change the peak position and resolution. Reflectron This is set expressed as a percentage of the flight tube voltage and its value is 1780V. Adjusting this will change the peak position and resolution. Pusher Offset This is the DC value applied to the puller plate to collimate the beam. Normal value is -1V. The value shown in the display is for illustration only. Pusher This sets the amplitude of the pusher pulse and is normally set to 830V. Puller This sets the amplitude of the puller pulse and is normally set to 645V. Tune Page 87 6 Manual Pusher Cycle Time may be set between 30 µsec and 255 µsec. Setting Cycle Time at less than 30 µsec defaults to 30 µsec. Entering 0 µsec switches the pusher off. Increasing the flight time reduces the duty cycle (sampling efficiency) of the TOF analyzer resulting in decreased sensitivity. For the best mass accuracy the instrument should be re-calibrated if the flight time is changed. If Manual Pusher is not selected then the repetition frequency of the pusher pulse is determined automatically according to the highest m requested in the acquisition range, as shown in the table below. MCP This sets the voltage on the TOF detector. MCP must be conditioned before applying high voltage (see Section 2.1.3 on page 23). The TOF analyzer is usually operated with this detector set at 2800V. The value shown in the display is for illustration only. It is recommended that a record of these values is kept for future reference. Manual Pusher If the Manual Pusher box is selected from the Other sub-menu then the repetition frequency of the pusher pulse is determined by the Cycle Time entered. See below. Width This is the width of the pusher pulse in µs, the default value is 9 µs but for low mass (< 80Da) acquisitions a lower value may be needed. Maximum Flight Time Highest 33 µsec 1000 47 µsec 1001 – 2000 66 µsec 2001 – 4000 94 µsec 4001 – 8000 132 µsec 8001 – 16000 188 µsec 16001 – 32000 88 Tuning 6 6.2.7 Other Tune Page Settings TDC Settings Figure 6-8 The TDC Settings Dialog To access the TDC (time to digital converter) settings select Options >TDC settings. Start This is the size of the trigger signal that is necessary to trigger the TDC (start the clock). The start signal is derived from the pusher voltage itself, and a typical value is 500mV. This voltage may be different in negative ion mode. Stop This is the size of pulse needed to register as being an ion, so stopping the clock. It is usually set at 150mV, a value high enough to prevent electronic noise being detected as ions. Threshold This parameter should normally be set to zero. Setting to 1 will cause all peaks in the spectrum with one count to be thresholded out. Centroid Threshold Any peak above this value in height (counts) will be classed as ions and a centroid will be produced Min Points Any peak above this value in width (bins) will be classed as ions and a centroid will be produced. NP Multiplier Used in deadtime correction calculations. A normal value is 0.7. Obtaining an Ion Beam 89 6 6.3 Obtaining an Ion Beam This section refers exclusively to the positive ion mode of operation using the ESI source. This is often the simplest mode of operation for getting and checking the ion beam. Note: This method should also be followed through when it is suspected there may be a problem with the instrument. It is likely that, should the user ever need to contact Micromass’ Technical Support specialists, they will ask that these steps have been performed. It is standard practice to use a sample with which the user is familiar. This sample should be of reasonable concentration and have at least one readily recognized component or pattern of masses. Commonly used compounds are listed below: A normal concentration is 2ng/µl. The general method outlined here can be used in either mode – positive or negative. Resolution Used in deadtime correction calculations. A normal value is 6000, but will vary according to instrument resolution. Lock Mass The mass to be entered in accurate /exact mass corrections to ensure data drift is minimized. Mass Window The window searched around the set lock mass in order to establish a suitable peak to be the lock mass Veff Effective flight tube voltage, used for setting up the non-calibrated mass scale. A normal value is 5630. Temp Correction Enables the DXC corrections to be applied, if installed. Lteff This is used to make the TOF mass measurement nominally correct without a calibration. The value is usually around 1080. See Chapter 7 for further details. Compound Mwt Leucine Enkephalin 556Da PEG 200/400/600 (mix) 100-1000Da Sodium Iodide 100-2500Da 90 Tuning 6 The sample should be infused at a rate of 5 µl/min via a syringe pump (on the instrument or otherwise) or using a dedicated LC system. This ensures a uniform, continuous spray that will last for a relatively long period. 6.3.1 Standard Tune Parameters 1. Enter the Standard Tuning Parameters (or load from a file) as described in Section 6.2 and Section 6.3. Ensure that the Peak Display window is open. 2. Switch the instrument into OPERATE. Press the button on the tune page marked ‘Press For Operate’ to get the following (the indicator goes to green and the button changes to ‘Press For Standby’) 3. Ensure that the API Gas , Col Gas , and Syringe , buttons are selected and operating. Note: It may take a while for the sample to appear in the peak display window as any dead volume will need to be cleared first. 4. Assuming that the probe is spraying the Peak Display window should be showing some response. Note: Adjustment of the Capillary and Sample Cone Voltage will vary the peak height and shape 6.3.2 Checking the Resolution While there may be a beam showing in the peak display, a single peak needs to be “Tuned” to give a resolution of at least 5000 (FWHM), for the QTof micro to perform to its specification. The resolution is calculated by the following equation: In the following example Leucine Enkephalin (2ng/ml) has been enthused at 5 µl/min. 1. Press the Tune Page Acquire button. This invokes the Tune page Acquisition dialog (Figure 6-9) Enter a Data File Name together with any necessary comments. Ensure TOF MS is selected for the Function and that the Data Format is set to Continuum. Resolution Mass = ( ) ÷ ( ) PeakWidthHalfHeight Obtaining an Ion Beam 91 6 Set the mass range from 100 Da to 1000 Da and a Duration of 1 minutes. The scan time can be any reasonable value, but a setting of 1s with an inter scan time of 0.1 s gives one second scans for each individual spectrum saved to disk. 2. Click Start. Figure 6-9 The Tune Page Acquisition Dialog 3. Open Chromatogram from the MassLynx Sample List menu and click on Real Time Update. 4. Combine data from at least 30 scans. On completion the Spectrum window will open Note: See the MassLynx User’s Guide for details on how to use Chromatogram, Spectrum and Combine. 5. In the Spectrum window Zoom in on the main peak at 556 Da. Note: Ensure that a Grid is shown on the Spectrum. Select Display > View to display the Spectrum Display dialog 92 Tuning 6 6. With the aid of the grid right click and drag the mouse across the width of the peak at half height. The width is show in the bottom left corner of the Spectrum window (Figure 6-10) Figure 6-10 Combined Spectrum of Leucine Enkephalin Showing Peak Width at Half Height 7. The resolution can now be calculated. In this case it is quite clearly adequate and above 5000. If the resolution is not above 5000 the process will have to be repeated with different tuning parameters. With experience it will possible estimate the resolution from the Peak Display on the Tune Page. Note: If a resolution of 5000 can not be achieved it is likely that there is a problem with the instrument and Micromass Technical Support should be contacted. Resolution = = 556.2214 0.0899 ÷ 6187 Introduction 93 7 Chapter 7 Calibration There are several steps to carrying out a Calibration for Accurate Mass on the Micromass Q-Tof Micro MS: 1. Calculation of Nominal Mass Accuracy (Section 7.2.1) 2. Acquire data for Calibration. (Section 7.2.20) 3. Check for Deadtime distortion (Section 7.2.3) 4. Calibration (Section 7.2.4) 5. Deadtime Correction (Section 7.2.6) You will need to refer to the following chapters of the MassLynx User’s Guide. • Chapter 6 – Chromatogram • Chapter 7 – Spectrum • Chapter 8 – Strip and Combine Note: To use the Calibration file for Accurate Mass refer to Chapter 15 “Accurate Mass Measure” of the MassLynx User’s Guide. 7.1 Introduction Extremely accurate mass measurements can be performed with the Q-Tof micro, due to the elevated resolution and inherent stability of the calibration law of orthogonal TOF instruments. The basic time of flight calibration from mass (m) to time (t) is of the form: where: The term P represents the resultant gain from the instrument geometry (pathlengths and voltages). = Q Pt + 94 Calibration 7 Q is an offset, arising from propagation delays through the electronics (detector rise time and delays of trigger signals through cables). If a data file is acquired from the instrument with no calibration applied, then it is assumed that the offset is zero and the gain P is calculated from the instrument geometry. 7.1.1 Nominal Mass Accuracy – Lteff Lteff is the effective length of the flight tube, it is important that this should be set up to give at least nominal mass accuracy. Nominal mass measurement is achieved on the Q-Tof micro by adjustment of the Lteff factor, a term which quantifies the difference between the indicated and actual mass. A TOF spectrum of a standard compound is acquired with Lteff set to its default value of 1078. A new value of Lteff can be calculated from the following relation: where: mind = indicated m/z mact = actual m/z The new value is entered on the Tune Page under Options > TDC Parameters (Figure 7-1). Lteff 1078 mind mact = ÷ Introduction 95 7 Figure 7-1 TDC Settings Dialog All Subsequent mass measurements will be nominally correct. This value should only ever need to be set once. 7.1.2 Calibration With no calibration applied, the spectral data in MassLynx is merely a set of mass intensity pairs {Mn, In} based upon instrument geometry. The inherent relationship between mass and time shown above makes it prudent to generate higher order calibration coefficients that are applied to the square root of the nominal masses {Mn}: where: The terms A, B, C, D…. are calculated by fitting a polynomial to the acquired mass spectral data. Mc is the calibrated displayed mass. • If a polynomial of order 1 is requested, the values for A & B are calculated, and the higher terms are set to zero. Mc A BMn CMn DM3 2⁄ = + + + n 96 Calibration 7 • For a polynomial of order 5 (the highest supported in MassLynx) there will be six terms generated. • When calibrating over a large mass range (>500 Da) it is advisable to use a higher order polynomial, as the deviations from the straight line fit become more appreciable. • Once a calibration has been generated from a reference compound such as PEG it should be used as an ‘instrument calibration’ to be applied to all subsequently acquired data. The procedure for this is described below. 7.1.3 Lock Mass Temperature variations in the environment and in the instrument power supplies can cause drifts in measurements of a few hundred parts per million (ppm) over the course of a day. For accurate mass work, the instrument should be kept in OPERATE at all times to enable stabilization of the power supplies. Users can compensate for instrument drift by applying a single point lock mass correction that recalculates the term B in the above equation. This can be done in two ways: 1. Using a Micromass LockSpray / NanoLockSpray Interface 2. Teeing in, post column, a Lock Mass reference compound. Note: There are inherent problems with the second approach which can lead to poor exact mass capability. Consequently we recommend that the first option is used when ever possible. 7.1.4 Deadtime Correction The data acquisition system for the instrument is a time to digital converter (TDC). This is an ion counting system which generates a mass spectrum by storing the arrival times of ions in a histogram memory. After the arrival and registration of an ion by the TDC there is a minimum time interval before a subsequent ion arrival can be registered. This is called the ‘dead time’ of the TDC and is of the order of 5 nanoseconds. At high ion currents some of the ions generated are not registered, leading to a shift to lower mass centroids, with consequently lower measured areas on reported peaks. Generation of an Instrument Calibration 97 7 However, the MassLynx software incorporates a correction facility which allows for accurate mass measurements to be achieved over a large range of ion currents, and the use of dead time correction is described below. 7.2 Generation of an Instrument Calibration Make up an analyte solution consisting of: PEG 300 (10 nanolitres/millilitre), PEG 600 (10 nanolitres/millilitre), in a stock solution of 2mM ammonium acetate in 50/50 acetonitrile/water. Dilute this by a factor of ten (with the stock solution) and introduce this to the instrument using a syringe pump operating at 5 microlitres per minute. Note: The Quad ramp is predetermined for every mass range and can not be set by the user. 7.2.1 Calculation of Lteff Figure 7-2 The Tune Page Acquisition Dialog 98 Calibration 7 To calculate Lteff it is recommended that a solution such as Leucine Enkephalin is used that will produce a single peak. 1. Make up a solution of Leucine Enkephalin at 2 ng/ml in 50:50 methanol:water. 2. Introduce this into the instrument with the syringe pump at 5 µl/min. 3. Click Aquire, this will invoke the Tune Page Acquisition dialog (Figure 7-2). 4. Acquire for about 2 minutes. 5. Combine the data and then Center the Spectrum. Note: For further information on Combining data see Chapter 8 of the MassLynx User’s Guide and for Centering Spectral data, Chapter 6. 6. Note the indicated mass. In this case 561.2170. Figure 7-3 Indicated Mass of Leucine Enkephalin prior to Lteff Correction Generation of an Instrument Calibration 99 7 7. Use this value and the actual mass of Leucine Enkephalin (556.2771) to calculate Lteff. In this case: Lteff = 1082.78. 8. Enter the new Lteff value on the TDC Settings dialog. 9. Repeat steps 3 – 5. The new Lteff setting will give a nominal mass accuracy for Leucine Enkephalin. Figure 7-4 Indicated Mass of Leucine Enkephalin after Lteff Correction. 7.2.2 Acquire Data for Calibration 1. Set the Cone Voltage (30 – 40 volts)so as to give a good distribution of PEG peaks. 2. Check the resolution as detailed in the previous chapter. 3. Acquire data for one minute over the range 100 – 1000 Da, with scan time of 1second (for details on Acquiring Data see Section 7.2.1 on page 97). 4. Combine at least 30 scans of data. 100 Calibration 7 Check that the signal is not too intense and that the data acquired does not have an ion count above 200 counts/sec. 7.2.3 Check for Deadtime Distortion With the data acquired in the previous section: 1. Select Process > Center from Spectrum, this invokes the TOF Spectrum Center dialog (Figure 7-6). Select the TOF button from this dialog to invoke the QTOF Accurate Mass dialog. Check that both the resolution and Np multiplier are set to 0 (Figure 7-5). Figure 7-5 The TOF Accurate Mass dialog 2. Center the Spectrum with the values shown in (Figure 7-6). For details on how to center spectra see the MassLynx User’s Guide. Generation of an Instrument Calibration 101 7 Figure 7-6 The TOF Spectrum Center Dialog 3. Re-center the data using a Resolution of 5000 and Np Multiplier of 0.7. Check that any differences in the centroided masses of the two centered spectra are less than 1 mDa Figure 7-7 Comparison of Centered Spectra With (top) and Without (bottom) Deadtime Correction If the difference between the two peaks is more than 1 mDa then repeat the acquisition with less intense peaks, either by dilution or by reducing the capillary voltage. Once a satisfactory centered spectrum has been acquired, save it in the spectrum history. 102 Calibration 7 7.2.4 Calibration 1. Select Calibration > Calibrate Instrument from the Tune Page. This invokes the Calibration Window (Figure 7-8). 2. Select the Reference file to use from the drop down list of the Calibration Window. (pehnh4, ref will give the correct masses with the sample used here). 3. Select Calibrate > From File. This will invoke he Display Calibration Graphs dialog (Figure 7-9). 4. Use the Browse option to select the centered spectrum which has been previously saved. In this example it is from the data file CJ0710_02. 5. Once the spectrum has been selected Click OK. Figure 7-8 The Calibration Window. Generation of an Instrument Calibration 103 7 Figure 7-9 The Display Calibration Graphs Dialog 6. The Centered Spectrum will now be processed and compared against the Calibration File. When the processing is complete the results are displayed in a new calibration window. 104 Calibration 7 Figure 7-10 Calibration Window Showing Residual Errors Note: The residual errors should all be less than 3 mDa. 7. Outliers can be removed from the calibration curve by right clicking the outlying peak in the reference file spectrum and clicking the associated peak on the data file spectrum. 8. The calibration parameters can be altered by selecting Edit to invoke the Calibration Parameters dialog (Figure 7-11). Set the Intensity Threshold to 5%. This will mean that lower intensity peaks will not be included in the calibration and will generally give a better fit. Generation of an Instrument Calibration 105 7 Figure 7-11 The Calibration Parameters Dialog A firth order polynomial has been chosen here, as a large mass range is being covered by the calibration. It can be useful to do a first order calibration initially so that outliers are spotted more easily. When these have been removed reset the curve to a fifth order. 9. When the parameters have been set Exit the window and Accept the Calibration (below). Figure 7-12 The Accept Calibration Dialog 10. The calibration will be updated with the time of the update displayed in the Calibration Window (Figure 7-8). Note: Always Select File > Save As before exiting the calibration window and save the calibration with a unique filename. Exiting directly may result in the Uncal default file being overwritten. 106 Calibration 7 7.2.5 LockMass Correction The application of a single point lock mass correction will now correct for subsequent instrument drift and bring masses back to within 5 ppm RMS, on the condition that there is no isobaric chemical interference with either lock mass or analyte peaks. The lock mass is found under the TOF Spectrum Center menu when QTOF is clicked: Centering the spectrum with these parameters will force the peak at 520 to be 520.333 exactly and recalibrate the entire mass spectrum. 7.2.6 Deadtime Correction If you wish to Acquire Accurate Mass data at above 200 counts/sec then a deadtime correction needs to be applied to the calibration. 1. Acquire a spectrum of PEG at the higher concentration of 10 nl/ml and create a centered spectrum with no lock mass and no correction. (All parameters set to zero.)(Figure 7-5) . Figure 7-13 Calibration Window Deadtime Distortion Generation of an Instrument Calibration 107 7 2. Follow steps for calibration in Section 7.2.4 on page 102, to when the Calibration results window is open and the residual errors are revealed. There should now be a reduction in the mass deviation observed between adjacent peaks of high and low intensity. 3. Repeat this process at subsequently lower values of Np until the deviation is minimized. Figure 7-14 Same data as Figure 7-13 but with Np multiplier of 0.7 At this point the peaks should lie close to the axis – the line of best fit: 4. Typical values for Np Multiplier will be about 0.7, and the Resolution used should be as measured on the instrument at mass 500. 5. Now that the deadtime correction has been set up, the difference in reported areas and masses between corrected and uncorrected centered data can be seen. In the example below, the 371 peak has been shifted by 8.7 mDa. 108 Calibration 7 Figure 7-15 Two Spectra One (bottom) with no Deadtime Correction and the Other (top) with. Further Notes The model successfully corrects for deviations of up to about 15 mDa at mass 500, at which point the limits of the model are reached, with no correction applied at higher ion current. Users should familiarize themselves with the ion current range over which successful mass measurements can be made. Once the Resolution and Np Multiplier figures have been evaluated they can be left active in the menu without affecting centered data in any adverse way. The procedure involved using the Spectrum, Make Calibration commands is a post-processing calibration, producing a data file of a particular format and with the extension .scl. The file resulting from the commands Instrument Calibrate, Save Calibration has the same file extension .cal, but it should be noted that because it is an instrument calibration file, it is of an incompatible format to that described above. Folders and naming conventions should be appropriately assigned. Exact Mass Measurement: Additional Hints 109 7 7.3 Exact Mass Measurement: Additional Hints • Best results are obtained if the lock mass gives an intensity of approximately 100 to 200 counts per second as shown on the real time tune display. • The lock mass should be chosen to be at the upper end of the mass range used. • Do not change transfer lens voltages without re-calibrating the instrument. • Changing Cone will not change the calibration. • Always be aware of possible chemical interference problems, either on the sample or the lock mass peak. • When performing a base calibration (using PEG, for example) better results may be obtained by using a stronger solution and moving the probe off axis to limit the ion current, rather than using a lower concentration. • This has the effect of minimizing any possible chemical interference from background ions. • Always check the stability of the spray (see the instructions for the setting of the probe tip in Maintenance and Fault Finding). • Short term variations in the spray produce fluctuations in the number of ions per peak per pusher pulse, giving rise to errors in the deadtime correction calculations. The number of ions per peak per pusher pulse is calculated from the ion current integrated over a period of time thus only giving an average value. • To obtain the best deadtime correction, only combine scans of a similar intensity, either at the top of a chromatographic peak or in the tail of a chromatographic peak. • This ensures the number of ions per peak per push is calculated correctly. • The deadtime correction algorithm can only correct for ion intensities and m shifts up to a limit. If the ion current approaches approximately 10,000 counts per peak (without correction) in one second then the limits of the model are being reached. • If the limits of the model are exceeded no correction is applied – the same result will be obtained by centring the data with Resolution and Np Multiplier set to zero. • If the limits of the deadtime correction algorithm are exceeded it may be possible to use the C13 isotope instead. • For the best mass accuracy when mass measuring doubly charged ions, it is advisable to use a doubly charged lock mass peak. • To obtain the true number of ions per peak, areas must be selected on the peak centre menu. 110 Calibration 7 • The standard deviation in the determination of the mass (strictly ) centroid of a triangular-shaped peak (σppm) due to ion statistics alone is given by the equation below. A triangle is assumed to be a close enough approximation to the shape of the mass spectrometer peak for the equation to be valid. σppm = 106 ∆M / M(24Np)0.5 ppm where: ∆M is the width (m) of a triangular peak across the base. M is the m value of the peak. Np is the number of ions per peak. Using the above equation we can calculate the number of ions per peak required to give a standard deviation of 5 ppm when measuring a peak at 500 m. Assuming 5000 (FWHM) resolution, so ∆M = 0.2 (width at base = twice width at half height), then: Thus standard deviations of less than 5 ppm cannot be expected unless the number of ions per peak is greater than 267. Np 0.22 1012 ( ) × 24 500 × 2 5 2 = ( ) ⁄ ( ) × = 267 Starting an Acquisition 111 8 Chapter 8 Data Acquisition The following sections of this chapter will guide you through the basic acquisition methods used in MassLynx. • Section 8.1, Starting an Acquisition • Section 8.2, Monitoring an Acquisition • Section 8.3, The Experiment Setup Editor • Section 8.4, Automated Data Dependent Acquisition (DDA) Before starting an acquisition the instrument will need to be tuned and calibrated (refer to Chapter 6, Tuning and Chapter 7, Calibration). You will also need to refer to the following chapters of the MassLynx User’s Guide. • Chapter 4 – Sample Lists • Chapter 6 – Chromatogram • Chapter 7 – Spectrum 8.1 Starting an Acquisition There are two ways of starting an acquisition: • single sample acquisition from the tune page. • multiple sample acquisition from the MassLynx sample list. 8.1.1 Starting an Acquisition from the Tune Page The easiest way to acquire data is directly from the tune page. 112 Data Acquisition 8 • Acquisitions can be started and stopped. • Inlet programs cannot be used. • Analog data cannot be acquired. • Multiple sample sequences cannot be acquired. To start a single sample acquisition: 1. Press Acquire on the tune page, or choose Acquire. This will invoke the Tune Page Acquisition Dialog. 2. Make any required changes to the settings. 3. Press Start Figure 8-1 Tune Page Acquisition Dialog Parameters Data File Name The can be up to 128 characters. If the file already exists on disk, a prompt is given to rename the file or to overwrite the existing one. The file is written to the data directory of the current project. Set Mass Specifies the precursor mass that is used for the TOF MSMS acquisition This control is disabled if the function selected is TOF MS. Start Mass and End Mass These specify the masses at which the scan starts and stops. Start Mass must be lower than End Mass. Starting an Acquisition 113 8 Pressing Origin allows additional information about the sample to be analyzed to be entered into the following fields: • Submitter • Job • Task • Conditions To change the directory into which data are acquired: 1. Cancel the acquisition. 2. Create a new project by choosing MassLynx top level file menu, Project Wizard or open an existing one by choosing Open Project, from the MassLynx top level file menu. 3. The Text area is used to enter the sample description. The description can be displayed on any output of the acquired data and has a maximum length of 74 characters. To display text on more than one line press CTRL+Return at the end of a line. 4. The type of acquisition Function used to collect the data can be either of the following: • Tof MS • Tof MS/MS More information is given in Function List Editor later in this chapter. The Data Format that are collected and stored on disk can be any of the following: • Centroid • Continuum • MCA Run Duration The length of the acquisition, measured in minutes. Scan Time Specifies the duration of each scan in seconds. Inter Scan Time Specifies the time in seconds between a scan finishing and the next one starting. During this period no data are stored. Calibration Allows an appropriate, previously generated calibration file for either positive or negative ion to be selected – see chapter entitled Calibration and Exact Mass. 114 Data Acquisition 8 More information is given on data formats later on in this chapter. 8.1.2 Multiple Samples The MassLynx top level screen contains a sample list editor for defining multiple experiments. The list of samples is set up using a spreadsheet style editor, which can be tailored to suit different requirements. For more information see the MassLynx User’s Guide, Chapter 4. 8.2 Monitoring an Acquisition Acquisition status is shown on the MassLynx screen. The run time is shown on the MS panel and the scan status, sample number and scan number are shown on the Status bar at the bottom of the page. 8.2.1 The Acquisition Status Window Figure 8-2 The Scan Report Dialog The acquisition status window, or scan report (Figure 8-2), provides a scan by scan statistical report of the progress of an acquisition. To display the scan report dialog, from the tune page: The Experiment Setup Editor 115 8 Select Options > Scan Status. This shows details of the scan currently being acquired. 8.2.2 Chromatogram Real-Time Update To view in real time the chromatogram that is currently being acquired: 1. Open the data file using the MassLynx data browser. 2. Press , or select Real-Time Update from the Display menu. The chromatogram display is updated as the acquisition proceeds. For Further Details see the MassLynx User’s Guide 8.2.3 Spectrum Real-Time Update To view in real time the spectrum that is currently being acquired: 1. Open the data file using the MassLynx data browser. 2. Press , or select Real-Time Update from the Display menu. 3. Select Enable Real-Time update. For Further Details see the MassLynx User’s Guide 8.2.4 System Manager To check the communications between the MassLynx software and the embedded PC: Select Options > Communications Status from the Tune page menu bar. 8.2.5 Stopping an Acquisition To halt the acquisition: 1. From the Tune page, press . 2. From the MassLynx screen choose Stop from the Run menu, or press . Data acquired up to this point is saved. 8.3 The Experiment Setup Editor The experiment setup editor is used to set up the function(s) that the mass spectrometer uses during an acquisition. A function list can be a mixture of MS or MSMS experiments 116 Data Acquisition 8 that can be arranged to run either sequentially or concurrently during an acquisition. Survey or parent functions must be run in isolation. Typical uses for mixed function acquisitions are the acquisition of several MSMS product ion spectra over different retention windows. A function list is produced, saved on disk and then referenced by name when an acquisition is started. A simple function list is shown above, containing only one function: a centroided mode TOF MS scan, between 100 and 1500 amu using ES+ ionization. Immediately above the function bar display is a time scale that shows from when the function is active, and for how long it runs. In this case the acquisition runs from 0 to 60 minutes. To access this dialog: Select MS Method from the MassLynx Instrument Shortcut bar. Figure 8-3 The Experiment Setup Editor One example of a function list shown in Figure 8-3 shows 3 different MSMS functions in sequential time windows is shown above. The currently selected function is highlighted and enclosed in a rectangular frame. If the display shows more than one function a new function can be selected either by clicking with the mouse, or by using the arrow keys on the keyboard. 8.3.1 The Experiment Setup Editor Toolbar The toolbar is displayed at the top of the tune window and allows some common operations to be performed with a single click. The Experiment Setup Editor 117 8 Create a new function of the Indicated type. 8.3.2 Adding a New Function To add a new function to the list: 1. Click one of the toolbar buttons, or select the required function from the Functions menu. The editor for the function type selected is displayed showing default values. 2. Make any changes required to the parameters and press OK to add the new function. The function editors for each scan type is discussed in detail later on in this chapter. 8.3.3 Modifying an Existing Function To modify an existing function: 1. Select the function in the function list. 2. Press , or double click on the function. This displays the appropriate editor for the function type and allows changes to be made. The function list display is updated to show any changes. Entering a new value in Total Run Time and pressing sets the maximum retention time for the experiment. The ratio of the functions defined is maintained. For example, if two functions are defined one from 0 to 5 minutes and the other 5 to 10 minutes then a Total Run Time of 10 minutes is displayed. If this value is changed to 20 then the first function now runs from 0 to 10 minutes and the second from 10 to 20 minutes. Create a new function list. Edit the selected function. Open an existing function list. Delete the selected function. Save the current function list to disk. Move the selected function up the list of functions. Print the current window in portrait format. Move the selected function down the list of functions. 118 Data Acquisition 8 8.3.4 Copying an Existing Function To copy an existing function: 1. Select the function in the function list. 2. Select Copy and then Paste from the Edit menu. 3. Modify the parameters as described above. 8.3.5 Removing a Function To remove a function: 1. Select the function in the function list. 2. Press , choose Delete from the Edit menu, or press Del on the keyboard. 3. When asked to confirm the deletion, select Yes. 8.3.6 Changing the Order of Functions Functions are displayed in ascending Start Time and End Time order and this order cannot be changed. For functions that have the same start and end time the order in which they are performed can be changed as follows: Highlight the required function. Press or repeatedly until the function is in the required position. The Experiment Setup Editor 119 8 8.3.7 Setting a Solvent Delay Figure 8-4 The Solvent Delay Dialog No data is stored during the solvent delay period, which means that solvent peaks that would normally be seen eluting on the TIC chromatogram are no longer seen. For APcI functions the APcI probe temperature is set to the value specified in the APcI Probe Temp control for the period of the solvent delay. To set a solvent delay for a function list: Select Options > Solvent Delay from the menu bar. 120 Data Acquisition 8 8.3.8 Analog Channels Figure 8-5 The Analog Data Dialog If an analog channel’s hardware option is fitted, up to 4 channels of analog data can be acquired, which are stored with the data acquired from the mass spectrometer. Analog channels are typically used to collect data from external units such as UV detectors or FID detectors. A reading is made from the external channel at the end of each scan and stored with the data for that scan. The resolution of the chromatography for an analog channel is therefore dependent on the scan speed used to acquire the mass spectrometry data. To access this dialog: Select Options > Analog Data from the Method Editor dialog. To store data for an analog channel: 1. Check the box(es) for the channel required. 2. Enter a textual description for each of the selected analog channels. This description is used on the analog chromatogram dialog as the channel description. See “Chromatogram” in the MassLynx User’s Guide. 3. Enter an Offset to align the external unit with the mass spectrometer. 4. Press OK. 8.3.9 Saving and Restoring a Function List To save a function list: 1. Choose Save As from the function list File menu. 2. Enter a new file name, or select an existing file from the list displayed. The Experiment Setup Editor 121 8 3. Press Save. If the file already exists on disk, confirmation is requested to overwrite the existing information. Press Yes to overwrite the file, or No to select a different name. When the editor is closed a prompt is issued to save any changed function lists. To restore a saved function list: 1. Choose Open from the function list File menu. 2. Select the name of the function list to open, either by typing its name or by selecting it from the displayed list. 3. Press Open. 8.3.10 Setting up an MS Scan Function The full scan function editor, activated by pressing or by selecting TOFMS Scan from the Functions menu, is used to set up centroid, continuum and MCA functions. The full scan function editor, activated by pressing or by selecting TOFMS Scan from the Functions menu, is used to set up centroid, continuum and MCA functions. 122 Data Acquisition 8 Figure 8-6 The TOFMS Scan Dialog Mass (m/z) Low Mass and High Mass specify the masses at which the scan starts and stops. Time (mins) Start Time and End Time specify the retention time in minutes during which this function becomes active, and data are acquired. Cone Voltage When Use Tune Page is checked, the cone voltage set on the tune page at the start of the acquisition is used. The cone voltage value cannot be altered during acquisition by typing new values into the tune page, since the new values are not downloaded during acquisition. This can only be done by acquiring from the tune page. The Experiment Setup Editor 123 8 Method Ionization Mode, specifies the ionization mode and polarity to be used during acquisition. Data, specifies the type of data to be collected and stored on disk. There are three options: • Centroid stores data as centroided, intensity and mass assigned peaks. Data are stored for every scan. • Continuum. The signal received by the interface electronics is stored regularly to give an analog intensity picture of the data being acquired. Data are not centroided into peaks, but are stored for every scan. Due to the fact that data are acquired to disk at all times, even when no peaks are being acquired, continuum data acquisition places some extra burden on the acquisition system as compared to centroided acquisition. Data files tend to be significantly larger than centroided ones and the absolute scanning speed (amu/sec) is slower. It is possible, however, to set a threshold below which the data are not stored. Depending on the nature of the data acquired, this can greatly reduce these effects. The threshold can be set so that data considered to be ‘noise’ can be discarded, thus improving data acquisition speed and reducing data file sizes. • Multi Channel Analysis (MCA). MCA data can be thought of as ‘summed continuum’, with only one intensity accumulated scan being stored for a given experiment. As each scan is acquired, its intensity data is added to the accumulated summed data of previous scans. An advantage of MCA is that random noise does not accumulate as rapidly as real data and therefore effectively averages out over a number of scans. This emphasizes the real data and improves the signal to noise ratio. The disadvantage of MCA is that, as there is only one scan, it cannot be used for time resolved data. For MCA, Scans to Sum defines the number of scans to sum to create a spectrum. Scan Duration (secs) Scan Time specifies the duration of each scan in seconds while Inter-Scan Delay specifies the time in seconds between a scan finishing and the next one starting. During this period no data are stored. 124 Data Acquisition 8 APcI Probe Probe Temp, in degrees centigrade, is enabled when Ionization Mode is set to APcI. When Use Tune Page Settings is selected the APcI probe temperature set on the tune page at the start of the acquisition is used. This control is enabled when the ionization mode is set to APcI. The APcI probe temperature value cannot be altered by typing new values into tune page during the acquisition since the new values are not downloaded during the acquisition. This can be done by acquiring from the tune page. Setting up MS-MS Scanning Functions Figure 8-7 The MSMS Scan Dialog Automated Data Dependent Acquisition (DDA) 125 8 The MSMS scan function editor is activated by pressing the MSMS button or by selecting TOF MSMS from the Functions menu. Many of the fields in the MSMS scan editor are similar to those described in Section 8.3.10 on page 121. Only fields that differ significantly are described below. Masses Set Mass specifies the precursor mass to be selected by the quadrupole for fragmentation in the gas cell. When multiply charged species are being analyzed care should be taken when selecting the High Mass to ensure that the mass range is sufficient to include product ions with a lower charge but a higher value than the precursor. Time The product ion spectra are acquired in the time window defined by the Start Time and End Time. Several MSMS scanning functions can be set up to either run sequentially or concurrently in overlapping time windows. Collision Energy When Use Tune Page Settings is checked, the collision energy set on the tune page at the start of the acquisition is used. 8.4 Automated Data Dependent Acquisition (DDA) For the automated MS/MS analysis of unknown compounds, the Micromass Q-Tof micro has a powerful software control system to enable the instrument to perform data dependent acquisition (DDA), switching from the MS to MS/MS mode and then returning to the MS mode using data dependent criteria. The advantage of this method is that it removes the requirement to analyze the sample in MS mode to identify the target precursor ions and then re-run the sample in MS/MS mode to acquire the MS/MS data from each of these precursors. This is particularly valuable in the analysis of unknown samples using on-line chromatography where the target precursor ions and their retention times may well be quite different for each sample. During acquisition the instrument is controlled by the MS FILE in the MassLynx Sample List. DDA can only be acquired using the Sample List and may not be started by acquiring from the Tune Page. 126 Data Acquisition 8 The MS FILE file is created using the method editor and then selected in the sample list in the usual way. 8.4.1 Creating a Data Dependent MS to MS/MS Switching Experiment Accessing the Method Editor In the MassLynx sample list, using the cursor to select the MS file, perform a right mouse button click and in the drop down menu select the Open command to access the Method editor for that MS file. Creating a New Experiment In the top banner of the Method editor window select File and in the drop down menu select New to create a new template with no predefined functions. Select the Survey button to create a data dependant acquisition. Clicking the Survey button will launch Survey Scan Dialog (Figure 8-8). There are 8 tabbed pages available. These are used to access all the relevant parameters for the data dependent function switching experiment. It is advisable to work through each page sequentially and fill in the appropriate values. Automated Data Dependent Acquisition (DDA) 127 8 8.4.2 Survey Figure 8-8 Survey Scan Dialog: Qtof MicroSurvey Page The mass range is used to define the start and end mass range for the MS data. Time (Mins), defines the start and end times for the complete experiment. The spectrum integration period (Scan Duration) and Inter-Scan Delay period for the MS data are selected. In the MS mode the minimum time required to transfer data from the embedded PC to the data file on the host PC is about 100 mSec. Scan times of less than 1 sec may be employed if required, but because the Inter-Scan Delay is fixed (by the data transfer rate) the duty cycle will decline at very fast acquisition rates. 128 Data Acquisition 8 The Cone Voltage must either be set to Use Tune Page or set in this window to a suitable value. 8.4.3 MS to MSMS Figure 8-9 Survey Scan Dialog: MS to MSMS Page This tab has all the appropriate values that dictate when to switch into the MS/MS mode from the MS mode. They are as follows: – Automated Data Dependent Acquisition (DDA) 129 8 MS to MSMS Switch Criteria The decision can be made using TIC or individual ion Intensity. Since multiple precursors may be selected for concurrent MS/MS experiments it is usual to set this to Intensity. It is useful to acquire some MS data to be able to measure the typical background level and the peak intensities from the sample peaks so that the detection Threshold can be set appropriately. Within the mass range of the MS survey scan any peaks that rise above the Threshold (in ion counts/sec) will be identified as candidate precursor ions for selection. To prevent the selection of the P+1 (13C) or P+2 (13C2) isotope peaks as additional candidate precursors a Detection Window is set. The window is an absolute mass value, i.e:- a setting of 1Da will extract a 1Da range of the m scale and identify only the most intense peak contained within that specific m range. A suitable value for 1+ and 2+ ions would be 2Da. Number of Components defines the number of precursor masses that can be selected for concurrent MS/MS data acquisition from one MS survey scan. Once the candidate precursor are identified the N most intense will be used for MS/MS. The maximum that can be specified is eight, but often a more suitable number for LC peaks about 10-20 sec wide at half height is 3 – 4. The detection criteria set here may be subsequently modified by charge state considerations (see later) Retention Time Window (seconds) This parameter is only active when an include or exclude file has been generated and is selected (see later). If an include or exclude file is utilized where a retention time is included (e.g. 18 mins), then this window is a time value in seconds which is added to the retention time during which the peak must elute to be selected for fragmentation. For example, a value of 30secs would mean the peak expected to elute at 18 mins must elute between 18.00 and 18.50 mins). Charge State These settings define the parameters used for the charge state recognition algorithm. Tolerance Window. The window used when measuring between adjacent peaks (isotopes). This should be a tight tolerance, and as a default set to 0.1Da. Mass Extraction Window. This value in Da is the mass range around the peak identified that is extracted to perform the CS recognition on. For peptide work a value of 2Da is recommended as a default. 130 Data Acquisition 8 (%) Intensity of Main Peak. This threshold value is utilized to remove low intensity noise peaks from being identified by the CS algorithm. A default value of 2% is recommended. Precursor Selection Everything. No user-predefined masses are used and all peaks will be selected automatically according to the criteria defined in the Automatic Function Switching parameters. Included Masses Only will perform MS/MS solely on those masses appearing in the Include Masses list, or file, (see later section page 7) provided that their intensities rise above the predefined threshold set in the MS to MS/MS switch criteria. Included Masses and Everything Else allows masses in the Include Masses list to take precedence. These will be selected even if there are more intense peaks that would have been selected automatically. Detected Precursor Inclusion Auto Exclude will exclude a m value and its associated detection window (which is now defined under the exclude tab) from subsequent selection. Always Include allows the immediate selection of a previously selected m value. Include After Time excludes a previously selected m value and its associated detection window, (which is now defined under the exclude tab) from subsequent selection for the period specified. This prevents multiple selection of the same precursor in the event of tailing from strong LC peaks, but allows the fragmentation of near isobaric components eluting at other retention times. The maximum value is 200 secs. Data Discard uninteresting survey scans stores only those survey scans which triggered an MS/MS experiment to disk. Depending on the exact nature of the experiment, discarding these scans may significantly reduce the data file size. Automated Data Dependent Acquisition (DDA) 131 8 8.4.4 MSMS to MS Figure 8-10 Survey Scan Dialog: MSMS to MS Page If the MSMS to MS switch method is set to Default then the mode change will be triggered by one of the mutually exclusive options selected in the MSMS to MS Switch Criteria. The Intensity falling below threshold option is measured on the base peak in the MS/MS spectrum. A value of 2-3 counts/sec is recommended for peptide work on Q-Tof micro. If the MSMS to MS switch method is set to After time then the mode change will be as for the default setting, except that if these criteria are not met then a maximum time can be set. (For example in the above case the switch would occur after 7 seconds assuming the intensity of the base peak in the MS/MS spectrum had not fallen below 2 counts/sec). These rules apply on a per precursor basis. For example if MS/MS were concurrently running on 3 precursors and one MS/MS spectrum fell below 2 counts/sec then MS/MS would be terminated on that precursor. The remaining 2 precursors would continue in MS/MS mode until either they fell below the 2 counts/sec threshold or each MS/MS precursor ion had been acquired for 7 seconds. If the intensity Threshold were set to 0 counts/sec then MS/MS acquisition would continue on all three functions until a total of 21 seconds had elapsed. It is useful to set this to be equal to an integral number of cycles of MS/MS spectrum acquisition. For example if the MS/MS Scan Time is 1 sec with an Inter Scan Delay of 132 Data Acquisition 8 0.1 sec and CE profiling is in operation then to get 3 scans at each of three different collision energies would require the After time parameter to be set to 9.9 sec. 8.4.5 MSMS Template Figure 8-11 Survey Scan Dialog: MSMS Template Page This page is used to set-up the parameters for the acquisition of the MS/MS data from each of the precursors. It is important that the correct Q-Tof tune file (.ipr file) is selected in the instrument parameter window, Automated Data Dependent Acquisition (DDA) 133 8 The mass range for the acquisition of the MS/MS data is independent of the mass range selected for the MS survey data as in the example shown here. The spectrum integration (Scan Duration) and Inter-Scan Delay period can also be different to those values chosen in the MS survey mode. The Collision Energy parameter will define a default collision energy that will be used if, for any reason, a value cannot be selected from the parameters defined later under the collision energy settings. 8.4.6 Include Masses Figure 8-12 Survey Scan Dialog: Include Masses Page 134 Data Acquisition 8 The Include Mass option allows a number of predefined m values to be included in the decision making process for switching from MS to MS/MS mode. There are two distinct modes of operation, which are defined in the MS to MSMS criteria (Section 8.4.4). Included Masses Only will restrict MS/MS data acquisition only to peaks having the same m as those defined in the Include Masses List, provided that these peaks rise above the threshold. Included Masses & Everything else will preferentially perform MS/MS on masses in the Included Masses List, even though more intense masses may have been automatically detected, provided that the included masses are above the detection threshold. The Listed option allows a list of m values separated by commas to be entered directly into the window. MS/MS experiments on these masses will be carried out using the parameters defined elsewhere. In contrast, the File option allows included masses to be read from a file and specific parameters (Retention Time, Collision Energy, Cone Voltage, Charge State) may be associated with these m values to override those parameter set elsewhere. The files may be created or modified using the New, Add, Delete, Save As and Save buttons as necessary. Charge State The Use Include By Charge State option allows the selection of only those charge states specified to be selected for MS/MS analysis. This may be useful for example where singly charged ions are usually from the background and it is desirable, therefore, to preclude them from analysis. The required charge states are specified and separated by commas as shown. It is possible to enter values greater than 4, but at present CE control is available only up to and including charge state 4. The Number of Include Components option allows for the maximum number of components above the detection threshold from which the candidate precursors will be selected. For low level studies where singly charged ions are not to be selected for MS/MS it is clear that there may be many candidates above the threshold, among which the multiply charged ions may be the minor components. The range for this parameter is 1 – 100 and a value of 60 or 80 would be a reasonable default value. However it should be noted that higher values slow down data processing and hence acquisition times. Automated Data Dependent Acquisition (DDA) 135 8 8.4.7 Collision Energy Figure 8-13 Survey Scan Dialog: Collision Energy Page Use Default Collision Energy When selected, all MS/MS data are acquired using the default collision energy specified in the MSMS template window (see Section 8.4.5). Use Collision Energy Profile This option allows a range of different collision energies to be used depending on the m value of the selected precursor. In addition, from 1 up to 5 collision energies may be used 136 Data Acquisition 8 for each precursor m to attempt to produce optimal fragmentation. Using the Browse button, files may be selected which have previously created collision energy profiles. Using the Modify button new profiles can be created using the Modify CE Profile window and its associated Add, Delete, New, Save and Save As options. The example shown is a typical set of collision energy profiles for peptides or protein digest applications. During the MS/MS experiment data are collected with the collision energy cycling through CE1, CE2….CEN on a per spectrum basis. Figure 8-14 The CE Profile Dialog Use Charge State Recognition This mode will allow the collision energy to be set according the charge state (z) and m of the precursor as determined from the charge state recognition algorithm. Collision energy files for charge states from 1, 2, 3 and 4 may be created and selected using the Browse button. In this mode collision energy profiling by cycling around a number of different energies is less likely to be required for peptide analysis. Automated Data Dependent Acquisition (DDA) 137 8 Using the Modify button new profiles can be created using the Modify Charge State window and its associated Add, Delete, New, Save and Save As options. The examples shown are a set of suggested collision energy profiles for peptides or protein digest applications when selecting 2+ ions for MS/MS analysis. Figure 8-15 The Modify Charge State Dialog 8.4.8 Exclude Masses The Exclude Mass option (Figure 8-16)allows predefined masses to be excluded from selection for MS/MS analysis. The Exclude Mass window is now defined on this page and a default value of at least 1000mDa should be selected for peptide work, otherwise C13 isotopes will still be selected for fragmentation. The Range option allows a list of m values separated by commas, or a mass range to be entered into the location in the Exclude Masses window. This is suitable for a small number of components. For a larger number of components and particularly for components or impurities not permanently present the File option can be used to specify m values and an associated retention time. The window around the retention time is specified in the MS to MSMS section above). 138 Data Acquisition Figure 8-16 Survey Scan Dialog: Exclude Masses Page Creating a Parent Ion Discovery Experiment 139 9 Chapter 9 Parent Ion Discovery Before starting a Parent Ion Discovery Experiment refer to Chapter 8, Data Acquisition. You will also need to refer to the following chapters of the MassLynx User’s Guide. • Chapter 4 – Sample Lists • Chapter 6 – Chromatogram • Chapter 7 – Spectrum 9.1 Creating a Parent Ion Discovery Experiment In the MassLynx sample list use the cursor to select the MS file. 1. Select MS Method from the Instrument Shortcut bar 2. Select File > New. to create a new template with no predefined functions. 3. In the drop down menu select New 4. Select to create a parent ion discovery experiment. This invokes the Parent Scan Dialog (Figure 9-1). This consists of 10 tabbed pages. 140 Parent Ion Discovery 9 9.1.1 Parent Survey Window Figure 9-1 Parent Scan Dialog: Parent Survey Page Masses (m/z) Specifies the start and end range of the low and high-energy survey spectra Time (Mins) Specifies the start and end times in minutes for the experiment. Cone Voltage Allows the user to select either the cone voltage currently in use on the active tune page or to specify a user defined value by entering a suitable value into the text box Creating a Parent Ion Discovery Experiment 141 9 Method Specifies the ionization mode and the mode of data collection. It is essential that centroid acquisition is selected as this technique relies on mass difference in the neutral loss experiment and absolute mass for the product ion experiment. Scan Duration Specifies the integration time for the low and high-energy survey scans. Typical values are 1 second for the scan and 0.1 second for the inter-scan delay. Collision Energy These are the collision energies used during the low and high energy survey spectra. Typically the low energy is performed at 10eV or lower, whilst the high-energy data acquisition is performed at the appropriate value to produce the desired fragmentation. If a LockSpray interface is configured the Reference Scan options become available. Scans to Average The parameter determines the number of reference scans to be averaged to provide a correction factor for exact mass measurements. Values between 5 and 10 are generally suitable. Frequency determines how often the reference will be selected and a value of 10 seconds is typical. Cone Voltage allows the use to select a suitable cone voltage for the reference compound being used. 142 Parent Ion Discovery 9 9.1.2 Product Ions Figure 9-2 Example of a Screen Capture If the parent ion discovery is to be triggered by the presence of product ions, the masses of these ions should be entered in the above list. Once created the list should be saved under a suitable name. Switch Criteria Any ion observed in the high-energy survey spectrum at the m specified above, +/- the detection window must exceed the Threshold (Counts/s) to be considered as the chosen product ion. Creating a Parent Ion Discovery Experiment 143 9 Detection Window +/- (mDa) is the mass window for detection placed around the product ion. Keeping this detection window low can increase the specificity of the experiment. Recommended value is 25 mDa. This value can be lowered to 10mDa in the case of an instrument operating with DXC or where a LockSpray interface is being used to apply a lock mass correction. If more than one product ion is entered in the list then the user must specify the Match as either requiring the presence of one/or more product ions. 9.1.3 Neutral Loss Figure 9-3 Parent Scan Dialog: Neutral Loss Page 144 Parent Ion Discovery 9 If the parent ion discovery is to be triggered by the detection of a neutral loss then the mass of the loss should be entered into the above list. The value of 97.9769, as in the above example, is the loss of H3P04, which is commonly observed from phosphopeptides. If multiply charged parent ions are to be considered the software will automatically adjust the mass of the neutral loss accordingly. 9.1.4 MSMS Template Figure 9-4 Parent Scan Dialog: MSMS Template This window is used to set-up the parameters for the MSMS data acquisition. It is important that the correct Q-Tof tune file (.ipr file) is selected in the instrument parameter window Creating a Parent Ion Discovery Experiment 145 9 9.1.5 MS to MSMS MS to MSMS Switch Criteria The decision can be made using TIC or individual ion Intensity. Since multiple precursors may be selected for concurrent MS/MS experiments it is usual to set this to Intensity. It is useful to acquire some MS data to be able to measure the typical background level and the peak intensities from the sample peaks so that the detection Threshold can be set appropriately. Within the mass range of the MS survey scan any peaks that rise above the Threshold (in ion counts/sec) will be identified as candidate precursor ions for selection. To prevent the selection of the P+1 (13C) or P+2 (13C2) isotope peaks as additional candidate precursors a Detection Window is set. The window is an absolute mass value, i.e:- a setting of 1Da will extract a 1Da range of the m scale and identify only the most intense peak contained within that specific m range. A suitable value for 1+ and 2+ ions would be 2Da. Number of Components defines the number of precursor masses that can be selected for concurrent MS/MS data acquisition from one MS survey scan. Once the candidate precursor are identified the N most intense will be used for MS/MS. The maximum that can be specified is eight, but often a more suitable number for LC peaks about 10-20 sec wide at half height is 3 – 4. The detection criteria set here may be subsequently modified by charge state considerations (see later) Mass (m) Specifies the m range over which MS/MS data will be acquired. Currently it is vital that both the parent survey and MS/MS template interrogate data over the same m range during the experiment. Cone Voltage Allows the user to select the cone voltage currently in use on the active tune page or to specify a value by entering it into the text box. Collision Energy Will define a default collision energy that will be used in the MS/MS experiment if, for any reason, a value cannot be selected from the parameters defined later under the collision energy settings 146 Parent Ion Discovery 9 Retention Time Window (seconds) This parameter is only active when an include or exclude file has been generated and is selected (see later). If an include or exclude file is utilized where a retention time is included (e.g. 18 mins), then this window is a time value in seconds which is added to the retention time during which the peak must elute to be selected for fragmentation. For example, a value of 30secs would mean the peak expected to elute at 18 mins must elute between 18.00 and 18.50 mins). Charge State These settings define the parameters used for the charge state recognition algorithm. Tolerance Window. The window used when measuring between adjacent peaks (isotopes). This should be a tight tolerance, and as a default set to 0.1Da. Mass Extraction Window. This value in Da is the mass range around the peak identified that is extracted to perform the CS recognition on. For peptide work a value of 2Da is recommended as a default. (%) Intensity of Main Peak. This threshold value is utilized to remove low intensity noise peaks from being identified by the CS algorithm. A default value of 2% is recommended. Precursor Selection Everything. No user-predefined masses are used and all peaks will be selected automatically according to the criteria defined in the Automatic Function Switching parameters. Included Masses Only will perform MS/MS solely on those masses appearing in the Include Masses list, or file, (see later section page 7) provided that their intensities rise above the predefined threshold set in the MS to MS/MS switch criteria. Included Masses and Everything Else allows masses in the Include Masses list to take precedence. These will be selected even if there are more intense peaks that would have been selected automatically. Detected Precursor Inclusion Auto Exclude will exclude a m value and its associated detection window (which is now defined under the exclude tab) from subsequent selection. Always Include allows the immediate selection of a previously selected m value. Creating a Parent Ion Discovery Experiment 147 9 Include After Time excludes a previously selected m value and its associated detection window, (which is now defined under the exclude tab) from subsequent selection for the period specified. This prevents multiple selection of the same precursor in the event of tailing from strong LC peaks, but allows the fragmentation of near isobaric components eluting at other retention times. The maximum value is 200 secs. Data Discard uninteresting survey scans stores only those survey scans which triggered an MS/MS experiment to disk. Depending on the exact nature of the experiment, discarding these scans may significantly reduce the data file size. Note: It is not recommended to use this function with the neutral loss or product ion experiment. 148 Parent Ion Discovery 9 9.1.6 MSMS to MS Figure 9-5 Parent Scan Dialog: MSMS to MS Page If the MSMS to MS Switch Method is set to Default then the mode change will be triggered by one of the mutually exclusive options selected in the MSMS to MS Switch Criteria. The Intensity falling below threshold option is measured on the base peak in the MS/MS spectrum. A value of 2-3 counts/sec is recommended. If the MS to MS Switch Method is set to After time then the mode change will be as for the default setting, except that if these criteria are not met then a maximum time can be set. (For example in the above case the switch would occur after 15 seconds assuming the intensity of the base peak in the MS/MS spectrum had not fallen below 3 counts/sec). Creating a Parent Ion Discovery Experiment 149 9 If Absence of Neutral Loss is selected the instrument will switch back to the MS mode if the presence of the tentatively assigned neutral loss cannot be identified in the MS/MS mode. This is highly recommended for phosphopeptide neutral loss experiments. 9.1.7 Include Figure 9-6 Parent Scan Dialog: Include Page The Include option allows a number of predefined values to be included as targeted precursor ions, for switching from MS to MS/MS mode. There are two distinct modes of operation, when operating with an include list and these are defined in the MS to MSMS criteria (see above). 150 Parent Ion Discovery 9 Included masses only will restrict MS/MS data acquisition only to peaks having the same as those defined in the Include Masses List, +/- include window in mDa, provided that these peaks rise above the threshold. Included masses and Everything else mode will preferentially perform MS/MS on masses in the Include Masses List, even though more intense masses may have been automatically detected, provided that the included masses are above the detection threshold. The Listed option allows a list of values separated by commas to be entered directly into the window or an range e.g. 500_1000. MS/MS experiments on these masses will be carried out using the parameters defined elsewhere. In contrast, the File option allows included masses to be read from a file and specific parameters (Retention Time, Collision Energy, Cone Voltage, Charge State) may be associated with these values to override those parameter set elsewhere. The files may be created or modified using the New, Add, Delete, Save As and Save buttons as necessary. Charge State The Include By Charge State option allows the selection of only those charge states specified to be selected for MS/MS analysis. This may be useful, for example, where singly charged ions are usually from the background and it is desirable to preclude them from analysis. The required charge states are specified and separated by commas as shown. It is possible to enter values greater than 4, but at present CE control is available only up to and including charge state 4. The Number of Include Components option window defines the maximum number of components above the detection threshold from which the candidate precursors will be selected. For low level studies where singly charged ions are not to be selected for MS/MS it is clear that there may be many candidates above the threshold, among which the multiply charged ions may be the minor components. The range for this parameter is 1 – 100 and a value of 60 to 80 would be a reasonable default value. It should be noted that raising this value will slow the acquisition process. Creating a Parent Ion Discovery Experiment 151 9 9.1.8 Exclude Figure 9-7 Parent Scan Dialog: Exclude Dialog The Exclude Mass window allows predefined masses to be excluded from selection for MS/MS analyses. The Exclude Mass window is now defined on this page and a default value of at least 1000mDa should be selected for peptide work, otherwise C12 and C13 isotopes will still be selected for fragmentation as separate peaks. An exclude Range e.g. 50_250 can be entered to prevent switching on solvent or background ions which are known not to be of interest. 152 Parent Ion Discovery 9 Alternatively, the Range option allows a list of values separated by commas to be entered into the location in the Exclude Mass window. This is suitable for a small number of components. For a larger number of components and particularly for components or impurities not permanently present the File option can be used to specify values and an associated retention time. The window around the retention time is specified in the MS to MSMS section above. 9.1.9 Collision Energy Figure 9-8 Parent Scan Dialog: Collision Energy Page Creating a Parent Ion Discovery Experiment 153 Use Default Collision Energy When selected all MS/MS data are acquired using the default collision energy specified in the MSMS template window. Use Collision Energy Profile Figure 9-9 The CE Profile Dialog The collision energy profile option allows a range of different collision energies to be used depending on the value of the selected precursor. In addition, from 1 up to 5 collision energies may be used for each precursor to attempt to produce optimal fragmentation. Using the Browse button, previously created files with collision energy profiles may be selected. Using the Modify button new profiles can be created using the Modify CE Profile window and its associated Add, Delete, New, Save and Save As options. During the MS/MS experiment data are collected with the collision energy cycling through CE1, CE2….CEN on a per spectrum basis. 154 Parent Ion Discovery The system will not interpolate values. MS/MS on any value of not included in this table will be performed using the default value set in the MS/MS template. Below is a typical collision energy profile covering the range 400 to 1000 . Use Charge State Recognition Figure 9-10 The Modify Charge State Dialog This mode will allow the collision energy to be set according to the charge state and of the precursor as determined from the charge state recognition algorithm. Collision energy profiles for charge states from 1, 2, 3 and 4 may be created and the text files selected using the Browse button. In this mode collision energy profiling by cycling around a number of different energies is not required. The system will linearly interpolate between values in the table. Using the Modify button new profiles can be created using the Modify Charge State window and its associated Add, Delete, New, Save and Save As options. The examples shown are a set of suggested collision energy profiles for peptides or protein digest applications when selecting 2+ ions for MS/MS analysis. 155 10 Chapter 10 Maintenance and Fault Finding Cleanliness and care are of the utmost importance whenever internal assemblies are removed from the instrument. • Always prepare a clear clean area in which to work. • Make sure that any tools or spare parts that may be required are close at hand. • Obtain some small containers in which screws, washers, spacers etc. can be stored. • Use tweezers and pliers whenever possible. • If nylon or cotton gloves are used take care not to leave fibres in sensitive areas. • Avoid touching sensitive parts with fingers. • Do not use rubber gloves. • Before reassembling and replacing dismantled components, inspect O rings and other vacuum seals for damage. Replace with new if in doubt. Should a fault occur soon after a particular part of the system has been repaired or otherwise disturbed, it is advisable first of all to ensure that this part has been correctly refitted and / or adjusted and that adjacent components have not been inadvertently disturbed. : This Chapter describes maintenance for the following integral parts of the Q-Tof micro: • Section 10.2, The Source • Section 10.3, The Electrospray Probe • Section 10.4, The APcI Probe • Section 10.5, The Analyzer Caution: Many of the procedures described in this chapter involve the removal of possibly toxic contaminating deposits using flammable or caustic agents. Personnel performing these operations should be aware of the inherent risks, and should take the necessary precautions. 156 Maintenance and Fault Finding 10 In addition further advice and tips are given in the following sections: • Section 10.6, Fault Finding • Section 10.7, Cleaning Materials • Section 10.8, Preventive Maintenance Check List 10.1 Electronics Maintenance 10.1.1 Cooling Fans and Air Filters Always ensure that none of the cooling fans is obstructed. It is essential that the fan filter is checked and cleaned at regular intervals, and replaced if there is any doubt about its effectiveness. 10.1.2 The Vacuum System The performance of the mass spectrometer will be severely impaired by the lack of a good vacuum in the ion transfer (hexapole) region or the analyzer. • An excessive analyzer pressure results in a general loss in performance indicated by a loss of resolution and an increase in the background noise. • As the vacuum deteriorates, the vacuum becomes insufficient to maintain the instrument in the operate mode. Before suspecting a leak, the following points should be noted: • The turbomolecular pumps will not operate if the rotary pump has failed. • If the rotary pump is not maintained, the oil may become so contaminated that optimum pumping speed is no longer possible. Initially, gas ballasting may clean the oil. If the oil in the rotary pump has become discolored, then it should be changed according to the pump manufacturer’s maintenance manual. • The turbomolecular pumps switch off if an over temperature is detected. This could be due to poor backing vacuum, failure of the water supply or a leak in the source or analyzer. Vacuum Leaks If a leak is suspected, the following basic points may help to locate it: Electronics Maintenance 157 10 • Leaks very rarely develop on an instrument that has been fully operational. Suspect components that have recently been disturbed. Leaks on flanges can usually be cured by further tightening of the flange bolts or by replacing the seal. • All seals are made using O rings. When refitting flanges pay attention to the condition of O rings. Any that are cut or marked may cause a leak. The O rings should be clean and free from foreign matter. A hair across an O ring is sufficient to prevent the instrument pumping down. • Source components that operate at, or slightly above, atmospheric pressure are not susceptible to vacuum leaks. In the unlikely event of a leak on a feedthrough, then the unit should be replaced or returned to Micromass for repair. Pirani Gauge The Pirani gauge head does not require routine maintenance. Active Inverted Magnetron Gauge In particular, the quadrupole analyzer gauge requires regular maintenance. For information on cleaning the active inverted magnetron (Penning) gauge, refer to the Edwards literature supplied with the instrument. 158 Maintenance and Fault Finding 10 Gas Ballasting Figure 10-1 Rotary Pump Gas ballasting serves two important purposes: • When rotary pumps are used to pump away solvent vapors, the solvent vapor can become dissolved in the pump oil causing an increase in backing line pressure. Gas ballasting is a method of purging the oil to remove dissolved contaminants. • Oil mist expelled from the rotary pump exhaust is trapped in the oil mist filter. This oil is returned to the rotary pump during gas ballasting. Gas ballasting should be performed routinely on a weekly basis for 30 minutes. If the source is used in the APcI or megaflow electrospray modes, more frequent gas ballasting is recommended. Gas ballasting is performed on the E2M28 pump by rotating the gas ballast valve 5 to 6 turns in a counterclockwise direction. It is normal for the rotary pump to make more noise when the gas ballast valve is open. Caution: Failure to gas ballast the rotary pump frequently leads to shortened oil lifetime which in turn may shorten rotary pump lifetime. The Source 159 10 Oil Mist Filter The E2M28 rotary pump is fitted with an Edwards EMF20 oil mist filter which traps oil vapor from the rotary pump exhaust. The trapped oil is then returned to the rotary pump during routine gas ballasting. The oil mist filter contains two elements; the odor element need not be changed, but the mist element must be changed every time the rotary pump oil is changed. • To change the element follow the instructions in the Edwards manual. Rotary Pump Oil The oil in the rotary pump should be maintained at the correct level at all times. Check the oil level at weekly intervals, topping up if necessary. It is important to monitor the condition of the oil regularly. Replace the oil when it has changed to a noticeable reddish brown color, or routinely at 4 month intervals (3000 hours operation). At the same time, replace the oil mist filter’s mist element (see above). Change the oil in the rotary pump as follows: 1. Gas ballast lightly for 30 to 60 minutes. 2. Vent and shut down the instrument as described in Routine Procedures. 3. It will be found easier to drain the oil while the pump is still warm. 4. Drain the oil through the drain hole situated near the oil level sight glass. 5. Flush the pump, then replace the drain plug and refill the pump with the correct grade oil to the correct level. 6. Gas ballast lightly for 30 to 60 minutes. For further servicing information refer to the manufacturer’s manual. Foreline Trap This is used to protect against the chance of pump oil backstreaming into the collision gas solenoid and/or the turbo pumps. The activated alumina should be changed according to the manufacturer’s instructions. 10.2 The Source The Z-spray source is a robust assembly requiring little maintenance. The source consists of three basic parts: 160 Maintenance and Fault Finding 10 • The probe adjustment flange. • The glass tube. • The source flange assembly. The probe adjustment flange and the glass tube can be readily removed, without venting the instrument, to gain access to the source block and sample cone. This allows the following operations to be performed: • Wiping the sample cone. • Removing the sample cone. • Fitting or removing the APcI corona discharge pin. • Fitting or removing the exhaust liner and cleanable baffle. • Fitting or removing the nanoflow electrospray interface. • Enabling or disabling the purge gas. The sample cone may be cleaned in situ, by gentle wiping with a cotton swab or lint tissue soaked with 50:50 acetonitrile:water. More thorough cleaning of the sample cone may be achieved by removing it from the source. This may also be done without venting the instrument, by closing the isolation valve located on the ion block. Less frequently it may be necessary to clean the ion block, the extraction cone and the hexapole lens, in which case the instrument must be vented. This should only be done when the problem is not rectified by cleaning the sample cone or when charging effects are apparent. Charging is evidenced by a noticeable progressive drop in signal intensity, often resulting in a complete loss of signal. Switching the instrument out of and back into operate causes the beam momentarily to return. The hexapole transfer lens should not require frequent cleaning. If it is suspected that the lens does need cleaning it may be withdrawn from the front of the instrument after removing the ion block support. 10.2.1 Cleaning the Sample Cone in Situ This may be necessary due to lack of sensitivity or fluctuating peak intensity, or if deposited material is visible on the outside of the sample cone. Proceed as follows: 1. On the MassLynx Shortcut bar launch the tune page. Caution: Cleaning the various parts of the source requires the use of solvents and chemicals which may be flammable and hazardous to health. The user should take all necessary precautions. The Source 161 10 2. Deselect Operate to put the instrument in standby mode 3. Switch off the LC pumps. 4. Disconnect the liquid flow at the rear of the probe. 5. Set Source Block Temp and either APcI Probe Temp or Desolvation Temp to 20°C to switch off the heaters. The cooling time will be significantly shortened if the API gases are left flowing. Figure 10-2 Removing The Source Enclosure When APcI Probe Temp or Desolvation Temp has cooled below 100°C: 6. Deselect API Gas to switch off the nitrogen supply. 7. Disconnect both gas lines from the front panel by undoing the knurled nuts. 8. Disconnect both electrical connections by pulling back on the plug sleeves to release the plugs from the sockets on the front panel. 9. Undo the two knurled thumb nuts that retain the probe and withdraw it from the source. Place it carefully to one side. Caution: Removal of the APcI probe or desolvation nozzle when hot may cause burns. Attention: Removal of the APcI probe when hot will shorten the probe heater’s life. 162 Maintenance and Fault Finding 10 10. Undo the three thumb screws and withdraw the probe adjustment flange and glass tube. Place the glass tube, end on, on a flat surface and place the probe adjustment flange on top of the glass tube. 11. If fitted, remove the APcI corona discharge pin. The sample cone is now accessible. 12. Using a suitable flat blade screwdriver rotate the isolation valve by 90° into its fully anticlockwise position. A small improvement in the analyzer vacuum may be observed as a result of this operation. The isolation valve (Figure 10-3) is closed when the slot is perpendicular to the direction of flow. 13. Carefully wipe the sample cone with a cotton swab or lint free tissue soaked in 50:50 acetonitrile:water or 50:50 methanol:water. Figure 10-3 The Source, With Housing Removed . 14. Dry the cone using nitrogen. Caution: When the source enclosure has been removed the source block is exposed. Ensure that the source block heater has cooled before proceeding. Attention: Do not attempt to remove any obstruction by poking. This may result in damage The Source 163 10 If the sample cone is still not clean, or if the aperture is partially blocked, proceed to the following section. Otherwise, when the cone is clean and dry: 15. Open the isolation valve. 16. Replace all removed components, following in reverse order the removal procedures. 10.2.2 Removing and Cleaning the Sample Cone It is not necessary to vent the instrument to remove the sample cone. The source block incorporates an isolation valve for this purpose. To remove the sample cone proceed as follows: 1. Follow the procedure in the previous section, to gain access to the sample cone. 2. Using a suitable flat blade screwdriver rotate the valve by 90° into its fully anticlockwise position. A small improvement in the analyzer vacuum may be observed as a result of this operation. The isolation valve is in the closed position when the slot is perpendicular to the direction of flow. Attention: The sample cone is a delicate and expensive component and should be handled with extreme care. 164 Maintenance and Fault Finding 10 Figure 10-4 Removing the Cone 3. Disconnect the cone gas inlet line (if fitted). 4. Take the sample cone extraction tool supplied in the source spares kit and screw it to the flange of the sample cone. 5. Remove the two sample cone retaining screws using a 1.5mm Allen key and withdraw the sample cone and cone gas nozzle (if fitted) from the ion block. 6. Remove the extraction tool, and separate the sample cone from the cone gas nozzle. Place both components in an ultrasonic bath containing 40:40:10 acetonitrile:water:formic acid or 40:40:10 methanol:water:formic acid. Rinse and sonicate with 50:50 acetonitrile:water or methanol:water. 7. Dry the cone and nozzle using nitrogen. To minimize down time fit a spare sample cone, obtainable from Micromass, at this stage. If material has built up on the exhaust liner and cleanable baffle: 1. Remove the cleanable baffle and the exhaust liner. Attention: Do not attempt to remove the baffle without first removing the sample cone, The Source 165 10 2. Clean these components, or obtain replacements. 3. Fit the cleaned (or the replacement) exhaust liner and cleanable baffle to the ion block. Note: Refitting the sample cone is a reversal of the removal procedure. 10.2.3 Removing and Cleaning the Source Block and Extraction Cone 1. From Tune Page menu bar select Vacuum > Vent. The rotary pump and the turbomolecular pumps switch off. The turbomolecular pumps are allowed to run down to 50% speed after which a vent valve automatically admits dry nitrogen. Figure 10-5 Source Block and Extraction Cone Removed 2. Remove the source enclosure and the sample cone as described in the previous section. When the Instrument has Vented: 3. Remove the two screws which secure the ion block and remove the ion block heater and the ion block. 166 Maintenance and Fault Finding 10 4. Separate the extraction cone and the PTFE insulating ring from the ion block. 5. Remove the plug and the PTFE sealing washer. 6. Remove the sample cone as described above. 7. Leaving the valve stem in place, immerse the ion block in an ultrasonic bath containing 50:50 acetonitrile:water or 50:50 methanol:water, followed by 100% methanol. 8. Clean the sample cone and the extraction cone using in turn: • concentrated formic acid. • 50:50 acetonitrile:water or 50:50 methanol:water. • 100% methanol. 9. Dry all components using a flow of nitrogen, or place them in a warm oven. Caution: Strong acid causes burns. Carry out this procedure in a fume cupboard using protective equipment. The Source 167 10 10.2.4 Removing and Cleaning the RF Lens Assembly Figure 10-6 Removing The RF Lens Assembly To remove the RF hexapole transfer lens assembly, proceed as follows: 1. Remove the ion block, as described above. 2. Remove the three screws retaining the ion block support and carefully withdraw it, together with the support liner and O rings, from the pumping block. 3. Using a lint free tissue to gently grasp the hexapole, carefully withdraw it. To clean the hexapole transfer lens proceed as follows: 4. Immerse the complete assembly in a suitable solvent (100% methanol) and sonicate in an ultrasonic bath. Attention: Take care not to scratch the internal bore of the pumping block as the hexapole lens assembly is withdrawn. 168 Maintenance and Fault Finding 10 Figure 10-7 The RF Lens Assembly 5. Thoroughly dry the assembly using a flow of nitrogen. In severe cases: 1. Remove, clean, dry and replace each rod separately (one at a time). 2. Reassemble the assembly with extreme care, checking the assembly against the diagram. 10.2.5 Reassembling and Checking the Source 1. Feed the hexapole transfer lens into the instrument, allowing the recesses in the differential aperture plate to locate onto the two support rails within the analyzer assembly. Ensure that the assembly is pushed fully in. 2. Check the condition of the O rings on the ion block support. Replace them if necessary. 3. Replace the ion block support, pushing it in against the springs of the hexapole assembly. 4. Replace the three retaining screws. 5. Fit the plug and sealing ring to the ion block. 6. Fit the insulating ring and extraction cone. 7. Offer the ion block up to the peek ion block support, locate the two dowels and push firmly. The Source 169 10 8. Replace the ion block heater. 9. Replace and firmly tighten the two retaining screws taking care not to over-tighten the screws. 10. On the tune page select Vacuum > Pump. 11. Replace the PTFE exhaust liner and cleanable baffle, if removed. 12. Replace the sample cone and, if the nanoflow option is to be used, the cone gas nozzle on the ion block. 13. Reconnect the cone gas supply (nanoflow operation only). 14. Plug the purge and cone gas outlets and fit the APcI corona discharge pin. 15. Fit the source enclosure and the probe adjustment flange. 16. Insert the APcI probe and connect the Nebuliser Gas line. 17. Select Inlet > Gas and turn on Nitrogen. Fully open the Nebuliser Gas valve. 18. Set Desolvation Gas to read back 400 l/h (monitored on the tune page). 19. Check for gas leaks using soap solution. 20. Reduce Desolvation Gas to 150 l/h. 21. Set Source Block Temp to 150°C, and APcI Probe Temp to 20°C 22. Select Operate on the tune page. 23. With Corona set to zero, check that the Cone readback is reading the correct set value. 24. Set Corona to 4.0kV. 25. Check that the Corona readback is 4.0 kV and that the Cone readback is still reading the same set value. 26. Check that all other readbacks on the tune page agree with the set values. 10.2.6 The Corona Discharge Pin If the corona discharge pin becomes dirty or blunt: 1. Remove it from the source. 2. Clean and sharpen it using 600 grade emery paper. Attention: The maximum operating temperature for the source heater is 150°C. Do not set Source Block Temp higher than 150°C. 170 Maintenance and Fault Finding 10 If the needle becomes bent or otherwise damaged it should be replaced. 10.3 The Electrospray Probe Indications that maintenance is required to the electrospray probe include: • An unstable ion beam. Nebulizing gas may be escaping from the sides of the probe tip. Ensure that the probe tip O ring is sealing correctly. The probe tip setting may be incorrect. Adjust the probe tip setting as described in Electrospray. The probe tip may be damaged. Replace the probe tip. There may be a partial blockage of the sample capillary or the tubing in the solvent flow system. Clear the blockage or replace the tubing. • Excessive broadening of chromatogram peaks. This may be due either to inappropriate chromatography conditions, or to large dead volumes in the transfer capillaries between the LC column or probe connection. Ensure that all connections at the injector, the column, the splitting device (if used) and the probe are made correctly. • High LC pump back pressure. With no column in line and the liquid flow set to 300 µl/min the back pressure should not exceed 7 bar (100 psi). Pressures in excess of this indicate a blockage in the solvent flow system. Samples containing particulate matter, or those of high concentrations, are most likely to cause blockages. Check for blockages at the tube connections and couplings to the injector, the column and, if used, the flow splitter. Attention: The probe tip is sharp, and may be contaminated with harmful and toxic substances. Always take great care when handling the electrospray probe. The Electrospray Probe 171 10 Concentrated formic acid can be injected to clear blockages. Rinse thoroughly afterwards. Blockage of the stainless steel sample capillary may occur if the desolvation heater is left on without liquid flow. This is particularly relevant for samples contained in involatile solvents or high analyte concentrations. To avoid this problem it is good practice to switch off the heater before stopping the liquid flow, and flush the capillary with solvent. A blocked stainless steel sample capillary can often be cleared by removing it and reconnecting it in the reverse direction, thus flushing out the blockage. • Gas flow problems Check all gas connections for leaks using soap solution, or a suitable leak searching agent such as Snoop. 10.3.1 Replacement of the Stainless Steel Sample Capillary Figure 10-8 Removing the Stainless Steel Capillary form the Source If the stainless steel sample capillary cannot be cleared, or if it is contaminated or damaged, replace it as follows: 1. Remove the probe form the source. 2. Disconnect the LC line from the probe and remove the finger-tight nut. 172 Maintenance and Fault Finding 10 3. Loosen the grub screw retaining the LC union. 4. Remove the two probe end cover retaining screws, and remove the probe end cover. 5. Unscrew and remove the probe tip. 6. Remove the LC union and adapter nut. Withdraw and discard the stainless steel sample capillary. 7. Remake the LC connection to the LC union. 8. Sleeve one end of new sample capillary with the PTFE liner tube. 9. Using a GVF/16 ferrule and the adapter nut, connect the sample capillary to the LC union, ensuring that both the liner tube and sample capillary are fully butted into the LC union. 10. Disconnect the LC connection and feed the sample capillary through the probe, ensuring that a 0.3mm graphitized vespel ferrule (GVF/003) is fitted. 11. Using a Rheodyne spanner, gently tighten the adapter nut onto the probe. 12. Replace the probe tip and adjust so that 0.5mm of sample capillary protrudes from the probe tip. 13. Replace the probe end cover and tighten the grub screw to clamp the LC union. 10.4 The APcI Probe Indications that maintenance to the APcI probe is required include: • The probe tip assembly becomes contaminated, for example by involatile samples if the probe temperature is too low during operation (300°C). • The appearance of chromatogram peak broadening or tailing. Samples that give rise to a good chromatogram peak shape in APcI (for example reserpine and common pesticides) should display peak half widths of the order 0.1 minutes for 10µl loop injections at a flow rate of 1 ml/min. The appearance of significant peak broadening or tailing with these compounds is most likely to be due to a broken fused silica capillary or probe tip heater assembly. • Low LC pump back pressure. For 50:50 acetonitrile:water at a flow rate of 1 ml/min, a LC pump back pressure less than 14 bar (200 psi) is indicative of a broken fused silica capillary or a leaking connector. • High LC pump back pressure. The APcI Probe 173 10 For 50:50 acetonitrile:water at a flow rate of 1 ml/min, a LC pump back pressure above 35 bar (500 psi) is indicative of a blockage or partial blockage in the fused silica capillary, in a LC connector or in the filter. It is advisable to change the inner filter pad on a regular basis (see “Replacing the Fused Silica Capillary” in the following pages). • Gas flow problems. Check all gas connections for leaks using soap solution, or a suitable leak searching agent such as Snoop. 10.4.1 Cleaning the Probe Tip Remove any visible deposits on the inner wall of the probe heater with a micro-interdental brush (supplied in the spares kit) soaked in methanol:water. Before starting an analysis: 1. With the probe out of the instrument, connect the nebulizing gas supply line. 2. Select API Gas and turn on Nitrogen. 3. Allow the gas to flow for several seconds to clear any debris from the heater. 4. Turn off Nitrogen. 5. Insert the probe into the source. 6. Select API Gas and turn on Nitrogen. 7. Raise APcI Heater gradually, starting at 100°C and increasing in 50°C intervals to 650°C over a period of 10 minutes. This procedure should remove any chemical contamination from the probe tip. Attention: Do not set APcI Heater to 650°C immediately as this may damage the probe heater. 174 Maintenance and Fault Finding 10 10.4.2 Replacing the Probe Tip Heater Figure 10-9 The APcI Probe Tip Heater 1. Remove the probe tip assembly by carefully loosening the two grub screws. 2. Disconnect the heater from the probe body by pulling parallel to the axis of the probe. 3. Fit a new heater assembly. 4. Reconnect the probe tip assembly. The APcI Probe 175 10 10.4.3 Replacing the Fused Silica Capillary Figure 10-10 Replacing the Fused Silica Capillary on the APcI probe With the probe removed from the source proceed as follows: 1. Remove the probe tip assembly and the heater, as described in the preceding section. 2. Remove the probe end cover by removing the two screws and the grub screws that retain the LC filter. 3. Loosen the filter from the adapter nut. 4. Unscrew the adapter nut from the probe. 5. Remove and discard the fused silica capillary. 6. Using a ceramic capillary cutter, cut a new length of 300µm o.d. × 100µm i.d. fused silica capillary, about 1 centimetre excess in length. 7. Using a GVF/004 ferrule and the adapter nut, connect the capillary to the filter ensuring that the capillary passes through the ferrule but stops short of the filter. 8. Feed the sample capillary through the probe, ensuring that a 0.4mm graphitized vespel ferrule (GVF/004) is fitted. 9. Using a ceramic capillary cutter, cut the capillary at the nebuliser so that between 0.5 and 1.0mm of capillary is protruding from the nebuliser. 176 Maintenance and Fault Finding 10 It is important to cut the capillary square. This should be examined using a suitable magnifying glass. 10. Undo the adapter nut from the probe and withdraw the capillary from the probe. 11. Remove 20mm of polyamide coating from the end of the capillary using a flame and clean with a tissue saturated with methanol. 12. Carefully re-feed the sample capillary through the probe ensuring that the graphitized vespel ferrule is still fitted. 13. Using a Rheodyne spanner, gently tighten the adapter nut to the probe. 14. Replace the probe end cover and retaining screws. 15. Using a 1.5mm Allen key, tighten the grub screw in the probe end cover to clamp the filter. 16. Replace the heater and probe tip assembly. 10.5 The Analyzer The analyzer element of any high performance quadrupole mass spectrometer is, of necessity, a precisely machined and aligned assembly. Q-Tof micro is fitted with a prefilter assembly designed to protect the main analyzer by absorbing the majority of any contamination. The prefilter is not as mechanically critical as the main rods, as it has only RF applied and is, therefore, not resolving. It does, however, act as a high pass filter, and will reject ions of low mass before they enter the main rods. Figure 10-11 The Prefilter and Main Analyzer of the Q-Tof micro The Analyzer 177 10 It is unlikely that there will be any means on site for measuring the assembly to the micron level required. If analyzer charging effects cannot be resolved by the techniques below, it is almost certain that the analyzer will have to be returned to Micromass for refurbishment. 10.5.1 Removing the MS1 and Collision Cell Optical Bench Assembly 1. Vent the system as described at the beginning of this chapter. 2. Remove the analyzer housing top plate. Working inside the MS1 analyzer housing proceed as follows: 3. Disconnect the two push-on connectors which take the analyzer RF through to the RF lens at the source end of the analyzer. 4. Disconnect the three push-on connections bringing RF and DC voltages to the gas cell (analyzer housing right hand side). 5. Disconnect the three push-on connections bringing RF and DC voltages to the hexapole transfer lens following the gas cell (analyzer housing right hand side). 6. Remove the gas line connection to the gas cell where it enters the gas cell. 7. Disconnect the push-on DC (pole bias) connection to the main filter. 8. Disconnect the heavy gauge copper RF/DC main filter supply from the feedthroughs on the left side of the naysayer housing. All connections to the ion optical bench (main filter assembly/gas cell/RF lens assembly) should now have been removed. 9. At the front and rear of the optical bench, remove the two 4mm Allen socket screws that secure the bench to the mounting flanges. Attention: Cleaning the analyzer on site is not a task to be undertaken lightly. It should be done only when there is clear evidence that the analyzer is the source of lack of performance. The main rods of the analyzer are precision ground, as are the ceramics in which they are mounted. Under no circumstances should any of the analyzer rods be removed from the ceramic mountings. Attention: Before removing the optics from the housing prepare a clean area where it may be placed in preparation for removing and cleaning the prefilter rods. 178 Maintenance and Fault Finding 10 10. Holding the optical bench assembly, using two of the clamps that secure the optical elements to the aluminium base plate, lift the rear end upwards to clear the vacuum housing and then withdraw the optical bench from the housing. 11. Once removed replace the vacuum housing lid to prevent the ingress of dust into the housing. 10.5.2 Dismantling and Cleaning the Entrance Prefilter Dismantling and cleaning of the entrance prefilter is a skilled procedure which should be entrusted only to a Micromass engineer. 10.5.3 Cleaning the MS1 Analyzer Assembly 1. Having removed the optical bench assembly as described above, remove the two top clamps that secure the main filter (including pre and post-filter assemblies) to the optical bench. 2. Roll up a narrow strip of absorbent lint-free paper. Pass one end through the gap between two adjacent main filter rods and back through the next gap so that the paper is wrapped one half turn around a rod. 3. Wet the paper with a solvent such as methanol, and move the strip up and down along the analyzer rod. 4. Remove the strip and use dry nitrogen gas from a cylinder (not compressed air) to blow out any dust or particles. It is not anticipated that the gas cell or hexapole transfer lens will require cleaning. 10.5.4 Replacing the MS1 and Gas Cell Optical Bench Assembly Reassembly is the reverse of the appropriate dismantling procedure. Take extra care to ensure that all electrical connections are correctly and securely made, and that the various mechanical assemblies are accurately aligned within the housing on their locating dowels. Attention: Under no circumstances should any of the analyzer rods be removed from the ceramic mountings. Attention: Tools, carborundum paper or micromesh must not be used to remove contamination from the main filter rods. Fault Finding 179 10 10.5.5 The MS2 Analyzer and Detector Assembly The orthogonal acceleration cell, reflectron and microchannel plate assemblies are separated from the MS1 and gas cell region by a differential pumping orifice. It is anticipated that this region of the instrument will not require routine maintenance under normal operating conditions. The microchannel plate system is at risk from failure properly to condition the detector following venting of the system to atmosphere or vacuum failure. 10.6 Fault Finding The majority of faults that occur can be traced to a malfunction of the ion source or inlet system. On systems equipped with more than one source, this can often be confirmed by changing sources to see if the fault “moves” with the source. Should a fault occur soon after a part of the system has been repaired or otherwise disturbed, it is advisable first of all to ensure that this part has been correctly refitted and adjusted, and that adjacent components have not been inadvertently disturbed. 10.6.1 No Beam Refer to the relevant chapters of this manual and check the following: Attention: It is strongly recommended that assistance is sought from Micromass if maintenance to any of the components within the TOF analyzer housing are thought to be necessary (e.g. excessive noise, spikes, loss of detector gain or abnormal TOF peak shapes). 180 Maintenance and Fault Finding 10 • The tune page real time display is activated by pressing the appropriate button on the tool bar of the tune page. • Normal tuning parameters are set and, where appropriate, readback values are acceptable. • All necessary cables have been correctly attached to the source and probe. • Solvent is reaching the probe tip and the solvent flow rate is as required. For solvent flow rates below 100 µl/min it may be necessary temporarily to turn off the nebulizing gas and remove the probe from the source to allow the solvent to be seen at the probe tip. • The flows of desolvation gas and nebuliser gas are on and are set to the correct flow rates. • The source has been assembled correctly and is clean. • The source isolation valve is open. If, after performing the above checks, the beam is still absent: 1. Acquire TOF data with a mass range extending down to m 20. 2. Check that there is an interference ‘peak’ at approximately m 55 due to the pusher pulse being switched off. If this interference peak is not present, either the pusher is not pulsing or the output from the detector is not reaching the TDC (time to digital converter). The most likely cause of an absent pusher interference pulse is a faulty attenuator. If the pusher interference peak is not present no data will be acquired. 10.6.2 Unsteady Beam Refer to the relevant chapters of this manual and check that: • Capillary (electrospray) and Sample Cone are tuned correctly. • The capillary is not protruding too far from the end of the probe. • The probe is not too far into the source. • The flow of solvent from the HPLC pump is correct and steady. To do this, remove the probe, degas the solvent, increase the flow rate for several minutes to purge any trapped air then reset and re-measure the flow rate. Fault Finding 181 • Solvents have been adequately degassed. • The nitrogen flow of desolvation gas and nebuliser gas is steady. The nitrogen supply pressure should be 7 bar (100 psi) ±10%. • Desolvation Temp is not set too high for the liquid flow rate used. High temperatures can vaporize solvent within the electrospray probe. Should the preceding checks fail to reveal the cause of the problem, proceed to the following section. 10.6.3 High Back Pressure For electrospray, a higher than normal back pressure readout on the HPLC pump, together with a slowing of the actual solvent flow at the probe tip, can imply that there is a blockage in the capillary transfer line or injection loop due to particulate matter from the sample. To clear the blockage: Remove the probe from the source and increase the solvent flow to 50 µl/min to remove the blockage. Often, injections of neat formic acid help to redissolve any solute which has precipitated out of solution. If the blockage cannot be cleared in this fashion: Remove the finger-tight nut and tubing from the back of the probe. If the back pressure remains high: Replace the tubing with new tube (or first try removing both ends of the tube). If the back pressure falls: Replace the stainless steel sample tube inside the probe (or try reversing the tube to blow out any blockage). Reconnect the tubing to the probe. The solvent flow can now be readjusted and the probe replaced into the source. To check the flow rate from the solvent delivery system, fill a syringe barrel or a graduated glass capillary with the liquid emerging from the probe tip, and time a known volume, say 10µl. 182 Maintenance and Fault Finding Once the rate has been measured and set, a note should be made of the back pressure readout on the pump, as fluctuation of this reading can indicate problems with the solvent flow. For APcI a higher than normal back pressure readout on the HPLC pump can imply that, after a long period of use, the filter pad requires replacement. 10.6.4 Loss of Sensitivity As the ion source becomes dirty after prolonged use, the performance will degrade. Unstable or reduced ion currents are indicators that the source needs cleaning. The usual remedy is to clean the source as described earlier in this chapter. An increase in the analyzer pressure above 4e-6 mbar can also cause loss of sensitivity, although the pressure at which this occurs will be sample dependent. 10.6.5 Incorrect Isotope Distributions Incorrect isotope distributions can be caused by: • The TDC Stop (mV) threshold being set too high. Refer to the tune page settings section of Routine Procedures for information regarding the setting of this parameter. • A faulty attenuator. Attenuators can fail so that they are open circuit (no beam or pusher interference ‘peak’ present), or they can fail such that they stop attenuating.The latter failure mode gives rise to incorrect isotope distributions. When the attenuator fails in this way the TDC Stop (mV) threshold can be increased to a significantly higher value than that used previously without reducing the beam intensity. In normal operation setting the TDC threshold above 200 or 250mV will start to reduce the beam intensity. If the attenuator has failed the TDC threshold can be increased to 500mV or higher before the beam intensity is reduced. 10.6.6 High Noise Levels High noise levels can either be chemical or electronic in nature. Chemical Noise Chemical noise usually originates from contaminated samples, solvents or source gases. Fault Finding 183 Chemical noise can be distinguished from electronic noise simply by stopping source ionization. If no liquid or gases are entering the source and all the source voltages are set to zero then the remaining noise will be electronic in nature. Electronic Noise Electronic noise can be caused by setting the TDC Stop (mV) threshold too low. Refer to the Tuning Chapter for information regarding the setting of this parameter. The microchannel plate detector can be damaged by failure to properly condition the detector following venting of the system to atmosphere. If the detector is producing microdischarges, excessive noise will be apparent on the baseline of mass spectra in the absence of any ion beam. Reducing the detector voltage will reduce the number of discharges and reduce the noise. 10.6.7 Poor Analyzer Vacuum Before suspecting a pump fault or vacuum leak (see Vacuum System earlier in this chapter) it is worth checking the inverted magnetron (Penning) gauge. If this gauge has become dirty it will indicate a poor vacuum, or even fail to register at all. For information on cleaning the gauge, refer to the Edwards literature supplied with the instrument. Note: If the instrument has been vented to atmosphere (instead of dry nitrogen) it may take one to two days before reaching the vacuum levels obtained prior to venting. Attention: It is strongly recommended that assistance is sought from Micromass if maintenance to the detector system is thought necessary. Attention: Assistance from Micromass should be sought if, due to symptoms such as excessive noise, spikes, loss of detector gain or abnormal peak shapes, maintenance to any of the components within the TOF analyzer housing is thought to be necessary. Caution: The instrument must be vented and electrically isolated at the supply outlet before removing the instrument’s covers to gain access to the active inverted magnetron gauge. 184 Maintenance and Fault Finding 10.7 Cleaning Materials It is important when cleaning internal components to maintain the quality of the surface finish. Deep scratches or pits can cause loss of performance. Where no specific cleaning procedure is given, fine abrasives should be used to remove dirt from metal components. Recommended abrasives are: • 600 and 1200 grade emery paper. • Lapping paper (produced by 3M). After cleaning with abrasives it is necessary to wash all metal components in suitable solvents to remove all traces of grease and oil. The recommended procedure is to sonicate the components in a clean beaker of solvent and subsequently to blot them dry with lint-free tissue. Recommended solvents are: • Isopropyl Alcohol (IPA) • Methanol • Acetone Following re-assembly, components should be blown with oil-free nitrogen to remove dust particles. 10.8 Preventive Maintenance Check List • Avoid venting the instrument when the rotary pump is gas ballasting. • Do not gas ballast the rotary pump for more than 2 hours under any circumstances. For full details of the following procedures, consult the relevant sections of this chapter and / or refer to the manufacturer’s literature. Attention: Many of the procedures described in this chapter involve the removal of possibly toxic contaminating deposits using flammable or caustic agents. Personnel performing these operations should be aware of the inherent risks, and should take the necessary precautions. Preventive Maintenance Check List 185 10.8.1 Daily • Gas ballast the rotary pump for 30 minutes at the end of a day’s megaflow or APcI operation. It is normal for the rotary pump noise level to increase during gas ballasting. 10.8.2 Weekly • Gas ballast for at least 30 minutes by rotating the gas ballast knob anticlockwise by 5 to 6 turns. When gas ballast is complete, check the rotary pump oil level and color. Oil that has become noticeably red in color should be replaced. • Check the water chiller level and temperature (if fitted). 10.8.3 Monthly Check all cooling fans and filters. 10.8.4 Four-Monthly • Change the mist element in the oil mist filter. • Change the oil in the rotary pump. Gas ballast lightly for 30 to 60 minutes both before and after changing oil. 186 Maintenance and Fault Finding 187 A Appendix A Reference Information The reference files listed in this chapter have all ion intensities set to 100%. Actual ion intensities are not, of course, all 100%, but the calibration software does not take account of the ion intensities and this is a convenient way to store the reference files in the required format. Most samples can be purchased from the Sigma chemical company. To order, contact Sigma via the internet, or by toll-free (or collect) telephone or fax: Internet: http://www.sigma.sial.com This site contains a list of worldwide Sigma offices, many with local toll-free numbers. Toll-free telephone: USA & Canada800-325-3010 Outside USA & Canada++1 314-771-5750 (call collect) Toll-free fax: USA & Canada 800-325-5052 Outside USA & Canada ++44 314-771-5750 call collect and ask for the fax machine) Direct fax: Outside USA & Canada ++1 314-771-5757 (this is a toll call) 188 A A.1 Positive Ion Ref. File Name Chemical Name [Sigma Code #] Molecular Mass / Uses UBQ Bovine Ubiquitin [U6253] 8564.85 650-1500 General HBA Human α globin [H753] 15126.36 700-1500 Hb analysis SOD Superoxide dismutase [S2515] 15591.35 900-1500 Hb (internal cal.) HBB Human β globin [H7379] 15867.22 800-1500 Hb analysis MYO Horse heart myoglobin [M1882] 16951.48 700-1600 General PEGH1000 Polyethylene glycol + ammonium acetate mixture PEG 200+400+600+1000 80-1000 ES+ and APcI+ calibration PEGH2000 Polyethylene glycol + ammonium acetate mixture PEG 200+400+600+1000 +1450 80-2000 ES+ calibration NAICS Sodium Iodide / Caesium Iodide mixture 20-4000 General, ES+ calibration NAIRB Sodium iodide / Rubidium Iodide mixture 20-4000 ES+ calibration 189 A A.1.1 Horse Heart Myoglobin Reference File: MYO.REF – Molecular Weight: 16951.48 A.1.2 Polyethylene Glycol PEG + NH4+ Reference Files: PEGH1000.REF, PEGH2000.REF Charge State Calculated  Value Charge State Calculated  Value Charge State Calculated  Value 28+ 606.419 21+ 808.222 13+ 1304.969 616.177 20+ 848.583 12+ 1413.633 27+ 628.841 19+ 893.192 11+ 1542.053 26+ 652.989 18+ 942.758 10+ 1696.158 25+ 679.068 17+ 998.155 9+ 1884.508 24+ 707.320 16+ 1060.477 8+ 2119.945 23+ 738.030 15+ 1131.108 7+ 2422.651 22+ 771.531 14+ 1211.829 Calculated  Value 63.04 459.28 855.52 1251.75 1647.99 107.07 503.31 899.54 1295.78 1692.01 151.10 547.33 943.57 1339.80 1736.04 195.12 591.36 987.60 1383.83 1780.07 239.15 635.39 1031.62 1427.86 1824.09 283.18 679.41 1075.65 1471.88 1868.12 327.20 723.44 1119.67 1515.91 1912.15 371.23 767.46 1163.70 1559.94 1956.17 415.25 811.49 1207.73 1603.96 2000.20 190 A A.1.3 Sodium Iodide and Caesium Iodide Mixture Reference File: NAICS.REF A.1.4 Sodium Iodide and Rubidium Iodide Reference File: NAIRB.REF A.2 Negative Ion Calculated  Value 22.9898 772.4610 1671.8264 2571.1918 3470.5572 132.9054 922.3552 1821.7206 2721.0861 3620.4515 172.8840 1072.2494 1971.6149 2870.9803 3770.3457 322.7782 1222.1437 2121.5091 3020.8745 3920.2400 472.6725 1372.0379 2271.4033 3170.7688 622.5667 1521.9321 2421.2976 3320.6630 Calculated  Value 22.9898 772.4610 1671.8264 2571.1918 3470.5572 84.9118 922.3552 1821.7206 2721.0861 3620.4515 172.8840 1072.2494 1971.6149 2870.9803 3770.3457 322.7782 1222.1437 2121.5091 3020.8745 3920.2400 472.6725 1372.0379 2271.4033 3170.7688 622.5667 1521.9321 2421.2976 3320.6630 Ref. File Name Chemical Name [Sigma Code #] Molecular Mass / Uses MYONEG Horse heart myoglobin [M1882] 16951.48 700-2400 General 191 A A.2.1 Horse Heart Myoglobin Reference File: MYONEG.REF A.2.2 Mixture of Sugars mixture Reference File: SUGNEG.REF A.2.3 Sodium Iodide and Caesium Iodide (or Rubidium Iodide Mixture Reference File: NAINEG.REF SUGNEG Sugar mixture of: maltose [M5885] raffinose [R0250] maltotetraose [M8253] corn syrup [M3639] 100-1500 Low mass range NAINEG Sodium Iodide / Caesium Iodide (or Rubidium Iodide) mixture 200-3900 ES- calibration Calculated  Value 891.175 1209.812 1882.490 940.741 1302.952 2117.927 996.138 1411.615 2420.632 1058.460 1540.036 1129.091 1694.140 Calculated  Value 179.06 665.21 1151.37 341.11 827.27 1313.42 503.16 989.32 1475.48 Calculated  Value 126.9045 1026.2699 1925.6353 2825.0008 3724.3662 192 A A.3 Preparation of Calibration Solutions A.3.1 PEG + Ammonium Acetate for Positive Ion Electrospray and APcI Prepare a solution of polyethylene glycols at the following concentrations: Use 50% acetonitrile and 50% water containing 2 mmol ammonium acetate. Use reference file PEGH1000.REF. A.3.2 PEG + Ammonium Acetate for Positive Ion Electrospray (Extended Mass Range) Prepare a solution of polyethylene glycols at the following concentrations: Use 50% acetonitrile and 50% water containing 2 mmol ammonium acetate. Use reference file PEGH2000.REF. 276.7987 1176.1641 2075.5296 2974.8950 3874.2604 426.6929 1326.0584 2225.4238 3124.7892 576.5872 1475.9526 2375.3180 3274.6835 726.4814 1625.8469 2525.2123 3424.5777 876.3757 1775.7411 2675.1065 3574.4719 PEG 200 25 ng/ml PEG 400 50 ng/ml PEG 600 75 ng/ml PEG 1000 250 ng/ml PEG 200 25 ng/µl PEG 400 50 ng/ml PEG 600 75 ng/ml PEG 1000 250 ng/ml PEG 1450 250 ng/ml 193 A A.3.3 Sodium Iodide Solution for Positive Ion Electrospray Method 1 Prepare a solution of Sodium Iodide at a concentration of 2 µg/µl in 50:50 propan-2-ol (IPA):water with no additional acid or buffer. Add Caesium iodide to a concentration of 0.05 µg/µl. The purpose of the caesium iodide is to obtain a peak at  133 (Cs+ ) to fill the gap in the calibration file between  23 (Na+ ) and the first cluster at  173, which would lead to poor mass calibration in this mass range. Do not add more CsI than suggested as this may result in a more complex spectrum due to the formation of NaCsI clusters. Use reference file NAICS.REF. Method 2 Prepare a solution of Sodium Iodide at a concentration of 2 µg/µl in 50:50 propan-2-ol (IPA):water with no additional acid or buffer. Add Rubidium iodide to a concentration of 0.05 µg/µl. The purpose of the rubidium iodide is to obtain a peak at  85 (85Rb+ ) with an intensity of about 10% of the base peak at  173. Rubidium iodide has the advantage that no rubidium clusters are formed which may complicate the spectrum. Note that rubidium has two isotopes (85Rb and 87Rb) in the ratio 2.59:1, giving peaks at  85 and 87. Use reference file NAIRB.REF. A.3.4 Sodium Iodide Solution for Negative Ion Electrospray Either of the above solutions is suitable for calibration in negative ion mode. In both cases the first negative reference peak appears at 127 (I–) and the remaining peaks are due to NaI clusters. Use reference file NAINEG.REF. 194 A Instrument Specifications 195 B Appendix B Instrument Specifications To enable the instrument to give its best performance the recommended environmental conditions and power and water supplies are outlined below. Preparation of the laboratory in advance will assist us in efficiently installing the instrumentt. B.1 Room Location Dimensions The Micromass Q-Tof micro MS is 180 mm wide by 635 mm deep by 1163 mm long and weighs 200 kg. It is mounted on 6 supporting feet. An external Edwards EM28 requires an additional 650 mm by 200 mm of floor space. In the event that the unit needs to be lifted, the side panels should be removed and suitable lifting bands passed beneath the bottom of the frame. These should be attached to a suitable device (hoist etc.) to raise the analyser unit in a safe and controlled way. Only trained personnel with the correct equipment should carry this out. A separate table 1200 mm by 730 mm is supplied for the computer terminal. Doorways through which the instrument is to be transported should be a minimum of 820 mm wide. In the laboratory a minimum clearance of 500 mm should be allowed all round the bench for service access, apart from at the rear of the instrument where 900 mm is required. Note: The instrument should not be placed close to heavy machinery (compressors, generators etc.) which give excessive floor vibration. B.2 Environment It is recommended that the instrument be sited in an air conditioned laboratory, in a draught free position and away from excessive amounts of dust. 196 Instrument Specifications B B.2.1 General Altitude: upto 2000m Pollution degree 1 in accordabce with IEC 664 Rotary Pump 150 to 400 C Instrument The maximum ambient laboratory temperature should not exceed 300 C, optimum temperature lies in the range 190 – 220 C. Short term (1.5 hour) variations should be no more than 2 0 C. The relative humidity should not exceed 70%. Heat dissipated into the laboratory from the instrument is about 1.2 kW. The instrument conforms to IEC 1010 – 1, Pollution Degree 1, and Installation Category II. B.2.2 Magnetic Fields OA-Tof instruments are relatively tolerant to stray magnetic fields. We would advise an upper limit of 10 Gauss for both AC and DC components of magnetic field measured at the mass spectrometer. B.2.3 Radio Emissions The instrument should not be placed within a RF field greater than 0.2 V/metre. This approximates to a 1W hand held unity gain transmitter at a distance of 10 m. Possible sources of RF emission include RF linked alarm systems or LANs, portable telephones and hand held transmitters. B.3 Water Supplies The heat dissipated into the cooling water is about 400 Watts. The water flow required to dissipate the heat generated by the turbo pumps is 35 L/hour for an inlet temperature of about 200 C or 23 L/hour at an inlet temperature of about 150 C assuming an outlet temperature of about 300 C. Instrument Specifications 197 B The water may be supplied by a recirculating chiller with the following characteristics:- • Heat dissipation into system: 400 W • Temperature stability: +/- 20 C • Minimum reservoir volume: 5 L • Minimum supply pressure:10 psi (outlet at atmospheric pressure). • Maximum supply pressure: 60 psi • Minimum flow rate at 150 C: 0.4 L/min The above assume that the outlet water temperature will be no more than 300 C. Inlet water temperatures below 150 C are not recommended since excessive condensation may form on exposed pipework. Alternatively, when there is a cooled water supply available it may be used either directly through the instrument or indirectly via a water-to-water heat exchanger. In this latter case the chilled water supply to the heat exchanger must be at least 100 C below the required inlet temperature for the instrument. One inlet and one outlet are required for the instrument. Reinforced 10mm (3/8 inch) flexible hose is preferred. To prevent blockage of the water pipes suitable in-line filters will be required to remove particulate matter from town water supplies when these are used. Operation above 2000 metres altitude may adversely affect the cooling of the system. B.4 Power Requirements The instrument requires a single phase 50 – 60 Hz, 230 V nominal power supply rated at 13 A (UK) or 15 A (Europe). An additional single phase 50 – 60 Hz, 230 V or 115 V nominal power supply rated at 5A (UK) is required to run the embedded PC. In the USA and Canada a single-phase 50 – 60 Hz supply at 230 V phase to neutral fused and rated at 15 A is required. Alternatively two phases of a 50 – 60 Hz 208 V phase to phase, 3 phase supply, rated and fused at 15 A may be used. It is mandatory that no other apparatus is connected to this supply. 198 Instrument Specifications B Circuit breakers are an acceptable alternative to fuses. The supply should be terminated in the laboratory no more than 2 m from the instrument with either a wall mounted isolator or socket and plug to be fitted to the instrument. Other supply voltages can be accommodated using a transformer to change the primary supply voltage to 230 V. Advance notice is required and Micromass should be contacted. On single-phase supplies the power supply should ensure that the line and neutral wires cannot be transposed. On pump start-up currents of up to 30 A may be drawn for several seconds. Time delay fuses and breakers are recommended to prevent nuisance tripping. A safety earth (ground) correctly rated must be provided in all cases. Data system components, chromatographs, syringe pumps etc. should be connected directly to laboratory power outlets (no ancillary outlets are provided on the instrument). A residual current device (RCD) is recommended for additional protection. In the case of instruments fitted with a transformer the RCD should be fitted in the supply side of the transformer. Supply brownout should not fall to less than half main voltage for greater than 20 msec duration. B.5 Gases and Regulators Nitrogen The instrument requires oil free dry nitrogen regulated at 7 bar (100 psi) minimum outlet pressure to provide nebulising and drying gas to the instrument. During API operation typical usage of nitrogen is about 400 L/hour, but under high flow rate conditions (Megaflow/APcI) this may increase to 650 L/hour. This equates, approximately, to the consumption of a large cylinder of compressed nitrogen each day and it may be preferred to use a liquid nitrogen dewar which may last several weeks. Collision Gases Typically Argon is used as the collision gas for CID experiments. This should be 99.9% pure, regulated at no more than 50 psi. Connection is via 1/8 inch OD stainless steel or copper tubing (NOT SUPPLIED). Instrument Specifications 199 B B.6 Exhaust Outlets Rotary Pump Outlet The rotary pump exhaust outlet must be vented to the atmosphere external to the laboratory clear from any air intakes for air conditioning systems. A 12 mm (1/2 inch) hose connection is required. If the length of exhaust exceeds 4 m then the internal diameter of the pipe should be increased to 48 mm (2 inch) for the excess distance. Nitrogen Outlet Severe damage to the instrument will result if the electrospray/APcI exhaust is connected to the rotary pump exhaust line. This will occur when the nitrogen supply is off and rotary pump oil vapour will migrate via the source exhaust to the ion source and then through the sampling orifice into the quadrupole and gas cell assembly. A separate exhaust for the ion source gas (nitrogen) must be provided to the atmosphere external to the laboratory clear from any air intakes for air conditioning systems. A (6mm OD) hose connection is required. If the length of exhaust exceeds 3 m then the internal diameter of the pipe should be increased to 12 mm (1/2 inch) for the excess distance. B.7 Performance Specifications Time of Flight Mass Resolution, Positive Ion 5000 (FWHM) on (M+H)+ ion from Leucine Enkephalin. Time of Flight Mass Resolution, Negative Ion 5000 (FWHM) on (M-H)- ion from Raffinose. Full Scan MS Sensitivity, Positive Ion The signal height obtained from a sample consumption of 200 fmol of horse heart Myoglobin (16952 Da) will be greater than 166 ion counts on the most intense peak in the charge state envelope. A solution of 200 fmol/µL horse heart Myoglobin (in 50/50 acetonitrile/water + 0.2% formic acid) will be introduced at a flow rate of 5 µL/min. 200 Instrument Specifications B Full Scan MS Sensitivity, Negative Ion The signal height obtained from the sample consumption of 1 ng of raffinose will be greater than 200 counts on the (M-H)- peak at m/z 503. This will correspond to a signal to noise ratio of greater than 200:1 (after a 1×3 smooth). The instrument will be tuned at 5000 resolution (as demonstrated in specification 2a) and a solution of 5 ng/L in 50/50 acetonitrile/water (no additives) will be introduced at 10 µL/min. Full Scan MS/MS Sensitivity, Positive Ion The signal height obtained from a consumption of 20 fmol of [Glu1 ] -Fibrinopeptide B (1569 Da) will be greater than 6 counts on the most intense yî sequence ion from the MS/MS spectrum of the doubly charged precursor ion. This will correspond to a signal to noise ratio of greater than 30:1 (after a 3×9 smooth) on the most intense yî sequence ion. A solution of 100 fmol/µL will be introduced at a flow rate of 5 µl/min. Mass Measurement Accuracy (with internal reference) The RMS error between the measured and the accepted masses of peaks which have sufficient intensity and are free from interference from other masses, over the range from 150-900 Daltons, will be less than 5 ppm. One suitable peak of known mass will be used as an internal reference. The instrument will be tuned at 5000 resolution as demonstrated in specification 1a. B.7.1 Electrospray Option – Nanoflow Full Scan MS/MS Sensitivity, Positive Ion The signal to noise from a consumption of 2 fmol of [Glu1 ]-Fibrinopeptide B (1569 Da) will be greater than 30:1 (after a 3×9 smooth) on the most intense yî sequence ion from the MS/MS spectrum of the doubly charged precursor ion. A solution of 500 fmol/L concentration in MeOH/H2O + 0.2% formic acid solution and with glass micropipettes with 1 or 2 µm tips will be used. The integration period per spectrum will be about 5 sec and data will be summed over a period appropriate for the required consumption of sample. Instrument Specifications 201 B B.7.2 Electrospray Option – Transform Software (Software for the determination of molecular weight from a spectrum containing a series of multiply charged ions on a m/z scale by a transform of the data to a true mass scale.) Mass Measurement Accuracy (no internal reference) The mean measured mass of transformed data shall be 15867.2 +0.5 Da and the standard deviation (σ) of the mean <0.5 Da. The transform data will be created from five repeat analyses of the globin from normal human haemoglobin. Mass calibration to be performed using the multiply charged α globin peaks from a separate analysis. The raw data should be transformed over the range 15,000 – 16,000 Da and smoothed appropriately. The instrument will be tuned at 5000 resolution. It is recommended that a solution containing 10 pmol/µL of each globin in 50/50 acetonitrile/water + 0.2% formic acid is used. 202 Instrument Specifications Index 203 I N D E X A Accept Calibration 105 Accurate Mass 93 Acquisition Status Window 114 Add Task 34 Ammonium Acetate 192 Analog Channels 120 Analyzer Maintenance 176 APcI 67 Obtaining an Ion Beam 69 APcI Probe Maintenance 172 Argon 198 Atmospheric Pressure Chemical Ionization see APcI 67 Automatic Startup / Shutdown 28 B Borosilicate Capillary 55 C Caesium Iodide 190, 191 Calibration 93, 102, 113 Calibration Parameters 104 Calibration Solutions 192 Calibration Window 102 Camera System Nanoflow 60 Capillary 82 Capillary Voltage ElectroSpray 48 Centroid 123 Charge State 129, 146 Charge State Recognition 154 Checking the ESI Probe 44 Checking the Probe APcI 68 Checking the Resolution 90 Chromatogram Real-Time Update 115 Chromatographic Interfacing 52 Cleaning Materials 184 Cleaning Sample Cone 160 Collision Energy Parent 152 Survey 135 Collision Energy Profile 153 Collision Gases 198 Combine 91 Components 10 Electrical 10 Mechanical 10 Cone Gas ElectroSpray 48 Configure Contact Closures 31 Configure Shutdown on Error 30 Continuum 123 Conventions, documentation 3 Copy Function 118 D Daily Maintenance 185 Data Acquisition 111 Data File Name 112 Data System 18 Deadtime Correction 106 Delete Task 34 Index 204 Index I N D E X Desolvation Gas APcI 72 ElectroSpray 47 Detected Precursor Inclusion 146 Dialogs Accept Calibration 105 Analog Data 120 Calibration Parameters 105 Display Calibration Graphs 103 Gas Threshold 33 MCP Conditioning 23 Scan Report 114 Shutdown on Error Configuration 31 Solvent Delay 119 TDC Settings 88 TOFMS Scan 122 Tune Page Acquisition 91, 112 Dimensions 195 Documentation conventions 3 related 1 E Electrical Components 10 Electronics 17 Electronics Maintenance 156 Electrospray 39 ElectroSpray Operation 43 Electrospray Probe Maintenance 170 Electrospray Tip 45 Environment 195 Error Shutdown 30 ESI interface 39 ESI Source 43 Event Out 17 Exclude Masses Parent 151 Survey 137 Exhaust Outlets 199 Experiment Setup Editor 115, 116 Toolbar 116 Experimental Record 78 Extraction Cone Voltage 49 F Fault Finding 155, 179 Four-Monthly Maintenance 185 Front Panel Connections 14 Front Panel Controls 15 Function List 116 G Gas Ballasting 158 Gas Thresholds 32 Gases and Regulators 198 Glass Capillary Option 61 H Horse Heart Myoglobin 189, 191 I Include Masses Parent 149 Survey 133 Infusion Pump 40 Injection Valve 40 Insert Task 34 Installing Nanoflow 57 Instrument Specifications 195 Instrument Warm-up 24 Index 205 I INDEX Intensity Threshold 104 Internal Layout 9 Ion Optical System 76 Ion Optics 8 Ionisation Techniques APci 6 Ionization Techniques Electrospray 6 Nanoflow Electrospray 7 L LC column 39 LC-MS Sensitivity 53 Lock Mass 89 LockMass Correction 106 Log Parameters 37 Lteff 89, 94 M Maintenace Electrospray Probe 170 Source 159 Maintenance 155 Analyzer 176 APcI Probe 172 Manual Pusher 87 MCP 87 MCP Conditioning 23 Mechanical Components 10 Megaflow 43 Microscope Nanoflow 60 Mobile phase 39 Modify Function 117 Modify Task 34 Monthly Maintenance 185 MS to MSMS Parent 145 MS to MSMS Switch Criteria 129, 145 MSMS Template Parent 144 Survey 132 MSMS to MS 131 Parent 148 Survey 131 Multi Channel Analysis (MCA). 123 Multiple Sample Acquisition 114 Myoglobin 189, 191 N NanoFlow Electrospray 55 Nanoflow Interface 55 Nano-LC 55 Nano-LC Assembly 64 Nano-LC Option 63 Nanovial Tip Position 61 Nebuliser Gas ElectroSpray 47 Negative Ion 190 Neutral Loss Parent 143 New Function 117 Nitrogen 198 Nitrogen Gas In 16 Nitrogen Outlet 199 Nitrogen Supply 28 Nominal Mass Accuracy 94 NP Multiplier 88 O Obtaining an Ion Beam 89 APcI 69 ElectroSpray 45 206 Index I N D E X Oil Mist Filter 159 Operation ElectroSpray 43 Nanoflow 65 Origin 113 Outlets 199 P Parent Collision Energy 152 Exclude Masses 151 Include Masses 149 MS to MSMS 145 MSMS Template 144 MSMS to MS 148 Neutral Loss 143 Product Ions 142 Parent Ion Discovery 139 Parent Survey Window 140 Peak Display Tune Page 79 Performance Specifications 199 Pirani Gauge 157 Polyethylene Glycol 189 Polyethylene glycol 189 Positive Ion 188 Post-column Splitting 41 Power Failure 27 Power Requirements 197 Precursor Selection 146 Preparation APcI Operation 26 Electrospray Operation 25 For Startup 21 Preparation of Calibration Solutions 192 Preventive Maintenance 184 Probe Position ElectroSpray 46 Product Ions Parent 142 Purge Gas ElectroSpray 48 Q Quadrupole Tuning Page 83 R Rear Panel Connections 16 Reciprocating Pump 40 Reference compound 187 Related documentation 1 Remove Function 118 Resolution 90 Restore Function List 120 Room Location 195 Rotary Pump 13, 17 Rotary pump 13 rotary pump 13 Rotary Pump Oil 159 Rotary Pump Outlet 199 Routine Procedures 21 Rubidium Iodide 190 S Sample Cone 82 Sample Cone Voltage 49 Shutdown Editor 28 Toolbar 29 Shutdown Log 36 Shutdown Page 29 Sodium Iodide 190, 193 Sodium iodide 191 Solvent Delay 119 Source Index 207 I I N D E X Maintenance 159 Source Temp 82 Source temperature 48 Source Tuning Page 81 Spectrum Real-Time Update 115 Standard Tune Parameters 90 Start Up After Complete Shutdown 21 After Overnight Shutdown 24 Starting an Acquisition Multiple Samples 114 Tune Page 111 Status Display 15 Sugar mixture 191 Sugars 191 Supply Inlet 17 Survey Collision Energy 135 Exclude Masses 137 Include Masses 133 MS to MSMS 128 MSMS Template 132 MSMS to MS 131 Switch Criteria Parent 142 Syringe Pump 40 System Manager 115 T TDC Settings 88 The Auto Control Tasks Page 33 The Source 159 Time Of Flight Page 85 TOFMS Scan 122 Transient Pressure Trip 27 Tune Page 77 Tune Page Acquisition 111 Tuning 75 Tuning and Optimization ElectroSpray 46 Turbomolecular pumps 12 V Vacuum Leaks 156 Vacuum Protection 13 Vacuum System 12 Veff 89 W Water 16 Water Supplies 196 Weekly Maintenance 185 208 Index I N D E X

Leave a Reply

Your email address will not be published. Required fields are marked *